• Shopping Cart
    There are no items in your cart

UNE-EN IEC 61558-2-16:2026

Current

Current

The latest, up-to-date edition.

Safety of transformers, reactors, power supply units and combinations thereof - Part 2-16: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units for general applications

Available format(s)

Hardcopy , PDF

Language(s)

English, Spanish, Castilian

Published date

20-05-2026

€107.00
Excluding VAT

Replacement

This document of the IEC 61558 series deals with the safety of switch mode power supply

units and transformers for switch mode power supply units. Transformers incorporating

electronic circuits are also covered by this standard.

NOTE 1 Safety includes electrical, thermal and mechanical aspects.

IEC 61558-2-16 applies to:

a) switch mode power supply units incorporating safety isolating transformers providing

SELV, PELV or FELV AC or DC output voltage(s), or a combination thereof according to

IEC 61140 and IEC 60364-4-41 for use with household and other consumer products,

except for products covered by IEC 61347 series, IEC 61204-7, IEC 60065, IEC 60950-1

and IEC 62368 series;

b) switch mode power supply units with a maximum output voltage not exceeding 1 000 V

AC or 1 415 V ripple-free DC for use with household and other consumer products, except

for products covered in a) and products covered by IEC 61347 series, IEC 61204-7,

IEC 60065, IEC 60950-1 and IEC 62368 series;

c) IEC 61558-2-16 can be used for transformers for use in switch mode power supply

units (see Annex BB).

IEC 61558-2-16 covers the safety requirements for:

" separating SMPS for general use corresponding to IEC 61558-2-1;

" isolating SMPS for general use corresponding to IEC 61558-2-4;

" safety isolating SMPS for general use corresponding to IEC 61558-2-6;

" auto-SMPS for general use corresponding to IEC 61558-2-13.

For SMPS for specific applications corresponding to the other documents of the IEC 61558-2

series, the necessary requirements of the relevant documents of the IEC 61558-2 series are

applicable. In addition, the requirements listed in IEC 61558-2-16 apply. Where two

requirements are in conflict, the most severe take precedence.

NOTE 2 As the maximum rated supply voltage of the internal transformer is 1 000 V, the maximum rated

supply voltage of the switch mode power supply unit may be lower due to type of rectification.

Switch mode power supply units covered by this standard are air cooled (natural or forced)

independent, associated, stationary, portable, single-phase, or polyphase, with the rated

supply voltage not exceeding 1 000 V AC, the rated supply frequency not exceeding

500 Hz, the rated internal operating frequency exceeding 500 Hz, but not exceeding

100 MHz, and the rated output not exceeding 1 kVA or 1 kW, incorporating dry-type

transformers with encapsulated or non-encapsulated windings.

NOTE 3 For higher frequencies, additional requirements may be necessary. However, this standard may be used

as a guide.

IEC 61558-2-16 is applicable to switch mode power supply units, converters and inverters

without limitation of the rated output subject to an agreement between the purchaser and the

manufacturer.

NOTE 5 In the context of this standard, converters and invertors are considered to be switch mode power

supply units.

The no-load output voltage or the rated output voltage of switch mode power supply

units does not not exceed:

1 000 V AC or 1 415 V ripple-free DC when separating transformers or auto216 transformers are used;

500 V AC or 708 V ripple-free DC when isolating transformers are used;

50 V AC or 120 V ripple-free DC when safety isolating transformers are used.

The no-load output voltage or the rated output voltage of independent switch mode

power supply units does not be less than:

50 V AC or 120 V ripple-free DC when separating transformers, isolating transformer

or autotransformers are used.

IEC 61558-2-16 may also be used as a guide for products not covered by the scope of this

standard, the scope of IEC 61204-7 or the scope of IEC 61347 series.

IEC 61558-2-16 does not apply to:

motor-generator sets;

uninterruptible power supplies (UPS) according to IEC 62040 (Part 1 or series);

switch mode power supply units covered by IEC 61204-7 (i.e., low-voltage power supply

devices, DC output, performance characteristics) and DC power and distribution

equipment and switch mode power supply units for use in applications covered by,

IEC 61010-1, and IEC 60601-1

light source control gear covered by IEC 61347 series;

external circuits and their components intended to be connected to the input terminals and

output terminals of the switch mode power supply units and transformers for switch

mode power supply units.

NOTE 4 IEC 61204-7 will be updated by SC 22E.

Attention is drawn to the following:

for switch mode power supply units and transformers for switch mode power

supply units intended to be used in vehicles, on board ships and aircraft, additional

requirements (from other applicable standards, national rules, etc.) may be necessary;

measures to protect the enclosure and the components inside the enclosure against

external influences such as fungus, vermin, termites, solar-radiation, and icing should also be

considered;

the different conditions for transportation, storage, and operation of the switch mode

power supply units and transformers for switch mode power supply units should also be

considered;

additional requirements in accordance with other appropriate standards and national

rules may be applicable to switch mode power supply units and transformers for switch

mode power supply units intended for use in special environments, such as tropical

environment.

Future technological development of switch mode power supply units can necessitate a

need to increase the upper limit of the frequencies; until then, IEC 61558-2-16 can be used as

a guidance document.

Unless otherwise specified, from here onward, the term SMPS covers switch mode power

supply units.

Committee
CTN 201/SC 96
DocumentType
Standard
Pages
45
PublisherName
Asociación Española de Normalización
Status
Current

Standards Relationship
IEC 61558-2-16:2021 Identical
EN IEC 61558-2-16:2025 Identical
IEC 61558-2-16:2021/COR1:2023 Identical

€107.00