• Shopping Cart
    There are no items in your cart

UNE-EN IEC 61800-9-2:2025

Current

Current

The latest, up-to-date edition.

Adjustable speed electrical power drive systems (PDS) - Part 9-2: Ecodesign for motor systems - Energy efficiency determination and classification (Endorsed by Asociación Española de Normalización in May of 2025.)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-05-2025

€165.00
Excluding VAT

This part of IEC 61800 specifies energy efficiency indicators of power electronics (complete drive modules (CDM), input or output sub drive modules (SDM)), power drive systems (PDS) and motor starters, all used for motor driven equipment.This document is an Energy Efficiency Publication according to IEC Guide 118 and specifies the methodology for the determination of losses of the complete drive module (CDM), the sub drive module (SDM), the power drive system (PDS) and the motor system.It defines IE and IES-classes, their limit values and provides test procedures for the classification of the overall losses of the motor system.Furthermore, this document proposes a methodology for the implementation of the best energy efficiency solution of drive systems. This depends on the architecture of the motor driven system, on the speed/torque profile and on the operating points over time of the driven load equipment. It provides a link for the energy efficiency evaluation and classification of the extended product.The methodology of the extended product approach and the semi analytical models are defined in IEC 61800-9-1.The structure of this document is as follows: " the losses of standardized PDS, standardized reference CDM (RCDM) and the mathematical model for their calculation are given and classified; " the reference motor (RM) and the reference CDM (RCDM) are defined. They are used for determining the efficiency class of a PDS if either the physical motor or physical CDM is unknown; " the requirements for the determination of the losses of a physical PDS and a physical CDM including correction factors for other types of CDM as defined as RCDM or SDM are given and compared to the PDS and RCDM; " the requirements for type testing and user documentation are given; " some exemplary losses of an overall system are illustrated in annexes; " information about system and drive topologies are given in annexes.Specific data for the RCDM and RM, limits for the PDS and IE/IES-classes are given for low voltage (100 V up to and equal to 1 000 V), single axis a.c./a.c. power drive systems with three phase motors. Geared motors are treated as standard motors when motor and gearbox can be separated. A methodology is given in addition how this reference data can also be applied to other topologies like a.c./d.c.or d.c./a.c.converters.All provided reference data is derived from PDS with induction motors. It may be used for various types of PDS with other types of motors as well, for example but not limited to, Electronically Commutated Motors (ECM), Permanent Magnet Motors (PM) or Synchronous Reluctance Motors (SYN-RM), and Line-Start Permanent Magnet Motors (LSPM).PDS requirements in this standard only apply to PDSs that are placed on the market as one single product, i.e. combination of motor and CDM that are not intended to be used separately.CDM requirements only apply to a CDM where the included SDMs have not already been evaluated according to SDM requirements.The following equipment is excluded from the scope:" High voltage CDM, SDM and PDS with a rated voltage above 1,0 kV a.c. or 1,5 kV d.c.;" Low voltage CDM, SDM and PDS with a rated voltage below 100 V a.c.;" High power PDS above a rated power of 1 000 kW;" High power CDM and SDM above a rated apparent output power of 1 209 kVA;" Low power PDS below a rated power of 0,12 kW;" Low power CDM and SDM below a rated apparent output power of 0,278 kVA;" PDS with geared motors where motor and gearbox cannot be separated, for example because of a common housing;" Servo PDS (consisting of frequency converter, motor and position feedback sensor);" CDM, BDM and SDM that are exclusively designed to drive servo motors;" PDS, CDM, BDM and SDM specifically designed for d.c. motor applications according to IEC 61800-1;" PDS where several motors are connected in parallel to a single CDM with one three-phase output." SDM with DC input and DC outputNOTE IEC 61800-9 (all parts) does not cover energy efficiency classification of driven equipment but provides input for the assessment according to the extended product approach.

Committee
CTN 203/SC 22
DocumentType
Standard
Pages
143
PublisherName
Asociación Española de Normalización
Status
Current

Standards Relationship
IEC 61800-9-2:2023 Identical

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

€165.00
Excluding VAT