UNE-EN IEC 62387:2022
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Radiation protection instrumentation - Dosimetry systems with integrating passive detectors for individual, workplace and environmental monitoring of photon and beta radiation (Endorsed by Asociación Española de Normalización in November of 2022.)
Hardcopy , PDF
01-11-2022
30-03-2023
This document applies to all kinds of passive dosimetry systems that are used for measuring:
the personal dose equivalent Hp(10) (for individual whole body monitoring),
the personal dose equivalent Hp(3) (for individual eye lens monitoring),
the personal dose equivalent Hp(0,07) (for both individual whole body skin and local skin
for extremity monitoring),
the ambient dose equivalent H*(10) (for workplace and environmental monitoring),
the directional dose equivalent H'(3) (for workplace and environmental monitoring), or
the directional dose equivalent H'(0,07) (for workplace and environmental monitoring).
This document applies to dosimetry systems that measure external photon and/or beta
radiation in the dose range between 0,01 mSv and 10 Sv and in the energy ranges given in
Table 1. All the energy values are mean energies with respect to the fluence. The dosimetry
systems usually use electronic devices for the data evaluation and thus are often computer
controlled.
NOTE 1 In this document, dose means dose equivalent, unless otherwise stated.
NOTE 2 For Hp(10) and H*(10) no beta radiation is considered. Reasons:
a) Hp(10) and H*(10) are a conservative estimate for the effective dose which is not a suitable quantity for beta
radiation.
b) No conversion coefficients are available in ICRU 56, ICRU 57 or ISO 6980-3.
NOTE 3 The maximum energy ranges are the energy limits within which type tests according to this document are
possible.
NOTE 4 Direct ion storage (DIS) dosemeters are covered in this document as they are often operated without an
online display but a separate reader.
The test methods concerning the design (Clause 8), the instruction manual (Clause 9), the
software (Clause 10), environmental influences (Clause 13), electromagnetic influences
(Clause 14), mechanical influences (Clause 15), and the documentation (Clause 16) are
independent of the type of radiation. Therefore, they can also be applied to other dosimetry
systems, e.g. for neutrons, utilizing the corresponding type of radiation for testing.
This document is intended to be applied to dosimetry systems that are capable of evaluating
doses in the required quantity and unit (Sv) from readout signals in any quantity and unit. The
only correction that may be applied to the evaluated dose (indicated value) is the one
resulting from natural background radiation using extra dosemeters.
NOTE 5 The correction due to natural background can be made before or after the dose calculation.
| Committee |
CTN 73
|
| DocumentType |
Standard
|
| Pages |
96
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| EN IEC 62387:2022 | Identical |
| IEC 62387:2020 | Identical |
| EN IEC 62387:2022 | Equivalent |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.