Energy performance of lamp controlgear - Part 3: Controlgear for tungsten-halogen lamps and LED light sources - Method of measurement to determine the efficiency of controlgear (Endorsed by Asociación Española de Normalización in May of 2022.)
Hardcopy , PDF
English
01-05-2022
This document defines measurement and calculation methods for specifying the efficiency
and the standby power of controlgear for tungsten-halogen lamps and LED light sources.
Note 1: This includes electromagnetic transformers and electronic convertors for tungsten-halogen lamps, as well
as electronic controlgear for LED light source(s).
Note 2: The term "LED light sources" includes LED modules and LED lamps.
This document is applicable for controlgear designed for use on DC supplies up to 1 000 V
and/or AC supplies up to 1 000 V at 50 Hz or 60 Hz.
For multipurpose power supplies only the lighting part will be considered.
NOTE Requirements for testing individual controlgear during production are not included.
This document does not apply to:
controlgear which form an integral part of lamps (LED light sources);
controlgear circuits with capacitors connected in series;
controllable electromagnetic controlgear.