UNE-EN ISO 14146:2024
Current
The latest, up-to-date edition.
Radiological protection - Criteria and performance limits for the periodic evaluation of dosimetry services for external radiation (ISO 14146:2024) (Endorsed by Asociación Española de Normalización in September of 2024.)
Hardcopy , PDF
English
01-09-2024
The quality of a supplier of a dosimetry service depends on both the characteristics of the approved
(type tested) dosimetry system1) and the training and experience of the staff, together with the
calibration procedures and quality assurance programmes.
This document specifies the dosimetric and organizational criteria and the test procedures to be
used for the periodic verification of the performance of dosimetry services supplying personal and/or
workplace and/or environmental dosemeters.
The performance evaluation can be carried out as a part of the approval procedure for a dosimetry
system or as an independent check to verify that a dosimetry service fulfils specified national or
international type test performance requirements under representative exposure conditions that are
expected or mimic workplace fields from the radiological activities being monitored.
This document applies to personal and area dosemeters for the assessment of external photon radiation
with a fluence-weighted mean energy between 8 keV and 10 MeV, beta radiation with a fluence-weighted
mean energy between 60 keV and 1,2 MeV, and neutron radiation with a fluence-weighted mean energy
between 25,3 meV, i.e., thermal neutrons with a Maxwellian energy distribution with kT = 25,3 meV,
and 200 MeV.
It covers all types of personal and area dosemeters needing laboratory processing (e.g.,
thermoluminescent, optically stimulated luminescence, radiophotoluminescent, track detectors or
photographic-film dosemeters) and involving continuous measurements or measurements repeated
regularly at fixed time intervals (e.g., several weeks, one month).
Active dosemeters (for dose measurement) may also be treated according to this document. Then, they
should be treated as if they were passive, i.e., the dosimetry service reads their indicated values and
reports them to the evaluation organization.
In this document, the corrected indicated value is the one given by the dosimetry systems as the final
result of the evaluation algorithm (for example, display of the software, printout) in units of dose
equivalent (Sv).
Environmental dosemeters for the quantity air kerma, Ka, or absorbed dose, D, may also be treated
according to this document. All dose values stated in Sv shall then be interpreted as equivalent values
in Gy.
| Committee |
CTN 73
|
| DocumentType |
Standard
|
| Pages |
27
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| I.S. EN ISO 14146:2024 | Equivalent |
| BS EN ISO 14146:2024 | Equivalent |
| EN ISO 14146:2024 | Identical |
| ISO 14146:2024 | Identical |
| EN ISO 14146:2024 | Equivalent |
| ISO 14146:2024 | Equivalent |