Corrosion of metals and alloys - Corrosion in artificial atmosphere - Accelerated corrosion test involving exposure under controlled conditions of humidity cycling and intermittent spraying of a salt solution (ISO 16701:2025)

Available format(s)

Hardcopy , PDF

Language(s)

English, Spanish, Castilian

Published date

29-04-2026

€109.00
Excluding VAT

This document defines a laboratory accelerated corrosion test method in two closely related variants.

They are used in assessing the corrosion resistance of metals in environments where there is a

significant influence of chloride ions, mainly as sodium chloride from e.g., winter road de-icing salt.

The test variants contain humidity dynamics in proportions found in outdoor environments affected

by corrosion and are balanced to receive realistic proportions of corrosion rates between various

commonly occurring materials, coatings and engineering designs. The results obtained do not

permit far-reaching conclusions on the corrosion resistance of the tested metallic material under

the whole range of environmental conditions in which it may be used. Nevertheless, the method

provides information on the relative corrosion resistance of a material exposed to a salt-contaminated

environment with varying humidity conditions. The two accelerated laboratory corrosion test variants

are applicable to:

metals and their alloys (ferrous and non-ferrous);

metallic coatings;

chemical conversion coatings;

organic coating on metals;

a combination of materials and coatings that include galvanic interactions and/or crevice conditions.

NOTE 1 If testing low-alloy stainless steels according to this document, especially austenitic grades, there is a

risk of receiving exaggerated pitting, not representative for most service environments.

NOTE 2 This document is not suitable for testing of wax and oil-based rust protection agents, due to the

constantly elevated temperature condition of the test.

NOTE 3 This document does not specify the dimensions of the tests specimens, the exposure period to be used

for a particular product, or the interpretation of the results. Such details are provided in the appropriate product

specifications.

Committee
CTN 112
DocumentType
Standard
Pages
48
PublisherName
Asociación Española de Normalización
Status
Current
Supersedes

Standards Relationship
EN ISO 16701:2025 Identical
ISO 16701:2025 Identical

€109.00
Excluding VAT