UNE-EN ISO 2719:2026

Current

Current

The latest, up-to-date edition.

Determination of flash point - Pensky-Martens closed cup method (ISO 2719:2025)

Available format(s)

Hardcopy , PDF

Language(s)

Spanish, Castilian

Published date

23-09-2026

€90.00
Excluding VAT

This document describes three procedures, A, B and C, using the Pensky-Martens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions, biodiesel and other liquids in the temperature range of 40 °C to 370 °C.

CAUTION For certain mixtures no flash point, as defined, is detected; instead a significant enlargement of the test flame (not halo effect) and a change in colour of the test flame from blue to yellowish-orange can occur. Continued heating can result in significant burning of vapours outside the test cup, and can be a potential fire hazard.

NOTE 1 Although, technically, kerosene with a flash point above 40 °C can be tested using this document, it is standard practice to test kerosene according to ISO 13736[5]. Similarly, lubricating oils are normally tested according

to ISO 2592[2].

Procedure A is applicable to distillate fuels (diesel, biodiesel blends, heating oil and turbine fuels), new and in-use lubricating oils, paints and varnishes, and other homogeneous liquids not included in the scope of procedures B or C.

Procedure B is applicable to residual fuel oils, cutback residua, used lubricating oils, mixtures of liquids with solids, liquids that tend to form a surface film under test conditions or are of such kinematic viscosity that they are not uniformly heated under the stirring and heating conditions of procedure A.

Procedure C is applicable to fatty acid methyl esters (FAME) as specified in specifications such as EN 14214[11] or ASTM D6751[13].

This document is not applicable to water-borne paints and varnishes.

NOTE 2 Water-borne paints and varnishes can be tested using ISO 3679.[3] Liquids containing traces of highly volatile materials can be tested using ISO 1523[1] or ISO 3679.

Committee
CTN 51/SC 3
DocumentType
Standard
Pages
41
PublisherName
Asociación Española de Normalización
Status
Current
Supersedes

Standards Relationship
DIN EN ISO 2719:2026-03 Equivalent
EN ISO 2719:2025 Identical
ISO 2719:2025 Identical

€90.00
Excluding VAT