UNE-EN ISO 80601-2-12:2025
Current
The latest, up-to-date edition.
Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators (ISO 80601-2-12:2023)
Hardcopy , PDF
Spanish, Castilian, English
22-01-2025
201.1 Scope, object and related standardsIEC 60601-1:2005+AMD1:2012+AMD2:2020, Clause 1 applies, except as follows:201.1.1 ScopeReplacement:NOTE 1 There is guidance or rationale for this subclause contained in Clause A.2.This document applies to the basic safety and essential performance of a ventilator in combination with its accessories, hereafter referred to as ME equipment:intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility;NOTE 1 For the purposes of this document, such an environment is referred to as a critical care environment.Ventilators for this environment are considered life-sustaining.NOTE 2 For the purposes of this document, such a ventilator can provide transport within a profesional healthcare facility (i.e. be a transit-operable ventilator).NOTE 3 A critical care ventilator intended for use in transport within a professional healthcare facility is not considered as an emergency medical services environment ventilator. intended to be operated by a healthcare professional operator; and intended for those patients who need differing levels of support from artificial ventilation including for ventilator-dependent patients.A critical care ventilator is not considered to utilize a physiologic closed-loop-control system unless it uses a physiological patient variable to adjust the ventilation therapy settings.This document is also applicable to those accessories intended by their manufacturer to be connected to a ventilator breathing system, or to a ventilator, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilator.NOTE 4 If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+AMD2:2020, 7.2.13 and 8.4.1.NOTE 5 Additional information can be found in IEC 60601-1:2005+AMD1:186 2012+AMD2:2020, 4.2.This document is not applicable to ME equipment or ME system operating in a ventilator-operational mode solely intended for patients who are not dependent on artificial ventilation.NOTE 6 A critical care ventilator, when operating in such a ventilator-operational mode, is not considered life190sustaining.This document is not applicable to ME equipment that is intended solely to augment the ventilation of spontaneously breathing patients within a professional healthcare facility.This document does not specify the requirements for:ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601-2-13[19];ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601-2-84[24];ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601-2-72[21];ventilators or accessories intended for home-care ventilatory support devices, which are given in ISO 80601-2-79[22] and ISO 80601-2-80[23];obstructive sleep apnoea therapy ME equipment, which are given in ISO 80601-2-70[20];continuous positive airway pressure (CPAP) ME equipment;high-frequency ventilators, which are given in ISO 80601-2-87[25];NOTE 7 A critical care ventilator can incorporate high-frequency jet or high-frequency oscillatory ventilator operational modes.respiratory high-flow therapy equipment, which are given in ISO 80601-2-90[26];oxygen therapy constant flow ME equipment;
| Committee |
CTN 110
|
| DocumentType |
Standard
|
| Pages |
188
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| EN ISO 80601-2-12:2023 | Identical |
| ISO 80601-2-12:2023 | Identical |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.