UNI EN 12391-1 : 2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
CHIMNEYS - EXECUTION STANDARD FOR METAL CHIMNEYS - PART 1: CHIMNEYS FOR NON- ROOMSEALED HEATING APPLIANCES
07-02-2008
12-01-2013
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Design criteria
4.1 Data requirements
4.1.1 Sources of data and information
4.1.2 Heating appliance information
4.1.3 Building construction and chimney route
information
4.1.4 Local conditions
4.1.5 Combustion air supply
4.1.6 Chimney product specification
4.2 Design requirements
4.2.1 General
4.2.2 Designation
4.2.3 Determination of designation of the chimney
and connecting flue pipe
4.2.4 Materials of construction
4.2.5 Flue size
4.2.6 Chimney route
5 Installation
5.1 General
5.2 Construction
5.2.1 System chimney
5.2.2 Relined chimney
5.2.3 Custom-built-chimney
5.3 Chimney plate
6 Commissioning
7 Inspection, cleaning and maintenance
7.1 General
7.2 Inspection and cleaning
7.3 Maintenance
Annex A (informative) Example of a metal chimney plate
A.1 Example of a metal system chimney plate
A.2 Example of relined metal chimney plate
A.3 Example of a custom-built chimney plate
Annex B (informative) Example for the determination of
the designation of a relined chimney
B.1 Input data for a typical relined chimney
B.1.1 Existing chimney
B.1.2 Relining
B.1.3 Insulation
B.2 Temperature class designation
B.2.1 General
B.2.2 Material characteristic
B.2.3 Resistance to fire
B.2.4 Human contact
B.2.5 Determination of temperature class
B.3 Pressure class designation
B.4 Resistance to condensate class designation
B.5 Corrosion resistance class designation
B.6 Soot fire resistance class and distance to combustible
material designation
B.7 Designation of the relined chimney
B.8 Example of chimney plate of the relined chimney in
this Example
Annex C (informative) Example of metal chimney product
designation
Annex D (normative) Determination of the chimney designation
for an installed system chimney
D.1 General
D.2 Temperature class
D.3 Pressure class
D.4 Resistance to condensate class
D.5 Corrosion resistance class
D.6 Soot fire resistance class and distance to combustible
material
Annex E (normative) Determination of the chimney designation
for relined of custom-built chimneys
E.1 General
E.2 Temperature class
E.3 Pressure class
E.4 Resistance to condensate class
E.5 Corrosion resistance class
E.6 Soot fire resistance class and distance to combustible
material
Annex F (informative) Material characteristics
Annex G (informative) Location of the chimney outlet
Annex H (informative) Method for calculating the temperature
of adjacent materials
H.1 Example for calculation the temperature of adjacent
materials
Annex I (informative) Checking, handling and site storage
of materials and components
I.1 General
I.2 Checking, handling and site storage of materials and
components
I.2.1 Checking on delivery of materials
I.2.2 Checking before inspection
I.2.3 Check of existing chimney
I.2.4 Site handling and storage
I.2.5 Coordination of work
Annex J (informative) Chimney commissioning test procedure
J.1 General
J.2 Flue flow test
J.3 Smoke test
J.4 Pressure test
Annex K (informative) Example for the determination of the
designation of a custom-built chimney
K.1 Input data for a typical custom-built chimney
K.1.1 Liner
K.1.2 Insulation
K.1.3 Enclosure
K.2 Temperature class designation
K.2.1 General
K.2.2 Material characteristic
K.2.3 Resistance to fire
K.2.4 Human contact
K.2.5 Determination of temperature class
K.3 Pressure class designation
K.4 Resistance to condensate class designation
K.5 Corrosion resistance class designation
K.6 Soot fire resistance class and distance to combustible
material designation
K.7 Designation of the custom-built chimney
K.8 Example of chimney plate of the custom-built chimney
in this Example
Annex L (informative) Example of chimney designation
Annex M (informative) Correlation between liner material
specification and corrosion load in Member States
Bibliography
Describes the method of specifying the design criteria and the installation method for building custom-built chimneys with rigid metal liners, for relining a chimney with rigid or flexible metal liners and for single wall system chimneys or multi-wall system chimneys with rigid metallic liners, used to convey the products of combustion from heating appliances to the outside atmosphere.
DocumentType |
Standard
|
PublisherName |
Ente Nazionale Italiano di Unificazione (UNI)
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 12391-1:2003 | Identical |
UNE-EN 12391-1:2006 | Identical |
DIN EN 12391-1:2004-04 | Identical |
BS EN 12391-1:2003 | Identical |
I.S. EN 12391-1:2004 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.