UNI EN 13069 : 2005
Current
The latest, up-to-date edition.
CHIMNEYS - CLAY/CERAMIC OUTER WALLS FOR SYSTEM CHIMNEYS - REQUIREMENTS AND TEST METHODS
26-09-2005
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Materials
5 Tolerances on dimensions
6 Compressive strength
7 Flexural strength under wind loading
8 Thermal shock
9 Resistance to fire
10 Thermal resistance
11 Water absorption and bulk density
12 Resistance to freeze-thaw
13 Evaluation of conformity
14 Test methods
15 Designation
16 Marking, labelling and packaging
Annex A (normative) Thermal resistance
Annex B (normative) Sampling procedures for an AQL
of 10 % and Inspection Level S2
Annex ZA (informative) Clauses of this European Standard
addressing the provisions of EU
Construction Products Directives
Bibliography
Defines the performance requirements for factory-made clay/ceramic chimney outer wall elements used to form the outer walls of chimneys and which are used in combination with flue liners in site.
Committee |
CT 20
|
DocumentType |
Test Method
|
PublisherName |
Ente Nazionale Italiano di Unificazione (UNI)
|
Status |
Current
|
Standards | Relationship |
NF EN 13069 : 2005 | Identical |
NBN EN 13069 : 2005 | Identical |
NEN EN 13069 : 2005 | Identical |
NS EN 13069 : 1ED 2005 | Identical |
I.S. EN 13069:2005 | Identical |
UNE-EN 13069:2006 | Identical |
SN EN 13069 : 2005 | Identical |
BS EN 13069:2005 | Identical |
EN 13069:2005 | Identical |
DIN EN 13069:2005-12 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.