• There are no items in your cart

UNI EN 54-12 : 2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM

Superseded date

23-08-2022

Published date

01-01-2003

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
   4.1 Compliance
   4.2 Individual alarm indication
   4.3 Connection of ancillary devices
   4.4 Manufacturer's adjustments
   4.5 On-site adjustment of response threshold value
   4.6 Protection against ingress of foreign bodies
   4.7 Monitoring of detachable detectors and
        connections
   4.8 Limit of compensation
   4.9 Additional requirements for software controlled
        detectors
        4.9.1 General
        4.9.2 Software design
        4.9.3 The storage of programs and data
   4.10 Fault signalling
5 Test methods
   5.1 General
        5.1.1 Atmospheric conditions for tests
        5.1.2 Operating conditions for tests
        5.1.3 Mounting arrangements
        5.1.4 Tolerances
        5.1.5 Measurement of response threshold value
        5.1.6 Provision for tests
        5.1.7 Test schedule
   5.2 Reproducibility
        5.2.1 Object
        5.2.2 Test procedure
        5.2.3 Requirements
   5.3 Repeatability
        5.3.1 Object
        5.3.2 Test procedure
        5.3.3 Requirements
   5.4 Directional dependence
        5.4.1 Object
        5.4.2 Test procedure
        5.4.3 Requirements
   5.5 Variation of supply parameters
        5.5.1 Object
        5.5.2 Test procedure
        5.5.3 Requirements
   5.6 Rapid changes in attenuation
        5.6.1 Object
        5.6.2 Test procedure
        5.6.3 Requirements
   5.7 Slow changes in attenuation
        5.7.1 Object
        5.7.2 Test procedure
        5.7.3 Requirements
   5.8 Optical path length dependence
        5.8.1 Object
        5.8.2 Test procedure
        5.8.3 Requirements
   5.9 Fire sensitivity
        5.9.1 Object
        5.9.2 Test procedure
        5.9.3 Requirements
   5.10 Stray light
        5.10.1 Object
        5.10.2 Test procedure
        5.10.3 Requirements
   5.11 Dry heat (operational)
        5.11.1 Object
        5.11.2 Test procedure
        5.11.3 Requirements
   5.12 Cold (operational)
        5.12.1 Object
        5.12.2 Test procedure
        5.12.3 Requirements
   5.13 Damp heat, steady state (operational)
        5.13.1 Object
        5.13.2 Test procedure
        5.13.3 Requirements
   5.14 Damp heat, steady state (endurance)
        5.14.1 Object
        5.14.2 Test procedure
        5.14.3 Requirements
   5.15 Vibration (endurance)
        5.15.1 Object
        5.15.2 Test procedure
        5.15.3 Requirements
   5.16 Electromagnetic compatibility (EMC), immunity
        tests (operational)
   5.17 Sulphur dioxide SO[2] corrosion (endurance)
        5.17.1 Object
        5.17.2 Test procedure
        5.17.3 Requirements
   5.18 Impact (operational)
        5.18.1 Object
        5.18.2 Test procedure
        5.18.3 Requirements
6 Marking and data
   6.1 Marking
   6.2 Documentation
        6.2.1 General
        6.2.2 Software documentation
Annex A (normative) Bench for response threshold
        value measurements
   A.1 Technical characteristics of the attenuators
   A.2 Measuring bench
Annex B (normative) Fire test room
Annex C (normative) Smouldering pyrolysis wood fire
        (TF2)
   C.1 Fuel
   C.2 Hotplate
   C.3 Arrangement
   C.4 Heating rate
   C.5 End of test condition
   C.6 Test validity criteria
Annex D (normative) Glowing smouldering cotton fire
        (TF3)
   D.1 Fuel
   D.2 Arrangement
   D.3 Ignition
   D.4 End of test condition
   D.5 Test validity criteria
Annex E (normative) Flaming plastics (polyurethane) fire (TF4)
   E.1 Fuel
   E.2 Arrangement
   E.3 Ignition
   E.4 End of test condition
   E.5 Test validity criteria
Annex F (normative) Flaming liquid (n-heptane) fire (TF5)
   F.1 Fuel
   F.2 Arrangement
   F.3 Ignition
   F.4 End of test condition
   F.5 Test validity criteria
Annex G (normative) Apparatus for stray light
   G.1 Installation
   G.2 The light source
Annex ZA (informative) Clauses of this European
         Standard addressing essential requirements or
         other provisions of EU Directives
Bibliography

Defines requirements, test methods and performance criteria for line detectors using an optical beam that detect smoke by utilising the attenuation and/or changes in attenuation of an optical beam, for use in fire detection and fire alarm systems installed in buildings.

DocumentType
Standard
PublisherName
Ente Nazionale Italiano di Unificazione (UNI)
Status
Superseded
SupersededBy

Standards Relationship
BS EN 54-12:2015 Identical
SN EN 54-12:2015 Identical
ONORM EN 54-12 : 2015 Identical
NBN EN 54-12 : 2015 Identical
DIN EN 54-12:2015-10 Identical
UNE-EN 54-12:2003 Identical
NF EN 54-12 : 2015 Identical
EN 54-12:2015 Identical
NS EN 54-12 : 2002 Identical
I.S. EN 54-12:2015 Identical
NEN EN 54-12 : 2015 Identical
DIN EN 54-12 E : 2015 Identical

UNI 11224 : 2011 INITIAL VERIFICATION AND MAINTENANCE OF AUTOMATIC FIRE DETECTION AND FIRE ALARM SYSTEMS
UNI 9795 : 2013 AUTOMATIC FIRE DETECTION AND FIRE ALARM SYSTEMS - DESIGN, INSTALLATION AND OPERATION

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.