VDE 0570-2-17 : 1998
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR - PART 2-17: PARTICULAR REQUIREMENTS FOR TRANSFORMERS FOR SWITCH MODE POWER SUPPLIES
12-01-2013
01-02-2012
Vorwort
1 Anwendungsbereich
2 Normative Verweisungen
3 Definitionen
4 Allgemeine Anforderungen
5 Allgemeines über die Prüfungen
6 Bemessungsdaten
7 Klassifikation
8 Aufschriften und weitere Informationen
9 Schutz gegen die Berührbarkeit von gefährlichen
aktiven Teilen
10 Änderung der Eingangsspannungseinstellung
11 Ausgangsspannung und Ausgangsstrom bei Belastung
12 Leerlauf-Ausgangsspannung
13 Kurzschlussspannung
14 Erwärmung
15 Kurzschluss- und Überlastschutz
16 Mechanische Festigkeit
17 Schutz gegen Staub, feste Gegenstände und Feuchte
18 Isolationswiderstand und Spannungsfestigkeit
19 Aufbau
20 Einzelteile
21 Innere Verdrahtung
22 Anschluss an den Versorgungsstromkreis und äussere
Anschlussleitungen/-kabel
23 Anschlüsse für äussere Leiter
24 Schutzleiteranschluss
25 Schrauben und Verbindungen
26 Kriech- und Luftstrecken sowie Abstände durch die
Isolierung
27 Wärme- und Feuerbeständigkeit sowie
Kriechstromfestigkeit
28 Rostschutz
Anhänge
Anhang C Isolierstoffgruppe II
Anhang D Isolierstoffgruppe I
Dieser Teil 2 von IEC 61558 gilt für luftgekühlte einphasige oder mehrphasige Gerätetransformatoren für Schaltnetzteile: - Netztransformatoren, - Trenntransformatoren, - Sicherheitstransformatoren mit einer Bemessungs-Eingangsspannung nicht über 1000 V Wechselspannung und einer Bemessungsfrequenz zwischen 500 Hz und 1 MHz. Die Bemessungsleistung überschreitet nicht: - 10 kVA für Einphasen-Transformatoren; - 16 kVA für Mehrphasen-Transformatoren. ANMERKUNG 1: Für höhere Frequenzen kann diese Norm als Leitlinie verwendet werden. Die Leerlauf-Ausgangsspannung oder die Bemessungs-Ausgangsspannung überschreitet nicht: - 1000 V Wechselspannung oder 1415 V geglättete Gleichspannung für Netztransformatoren; - 500 V Wechselspannung oder 708 V geglättete Gleichspannung für Trenntransformatoren; ANMERKUNG 2: Für Trenntransformatoren darf die Bemessungs-Ausgangsspannung bis zu 1000 V Wechselspannung oder 1415 V geglätteter Gleichspannung in Übereinstimmung mit nationalen Errichtungsbestimmungen oder für besondere Anwendungen betragen. - 50 V Wechselspannung (Effektivwert) und/oder 120 V geglättete Gleichspannung für Sicherheitstransformatoren. Diese Norm gilt für Trockentransformatoren. Die Wicklungen dürfen gekapselt oder ungekapselt sein. ANMERKUNG 3: Für Transformatoren, die mit einem flüssigen Dielektrikum oder einem pulverartigen Material wie z. B. Sand gefüllt sind, sind die Anforderungen in Beratung. ANMERKUNG 4: An Standorten, an denen spezielle Umgebungsbedingungen herrschen, können zusätzliche Anforderungen nach IEC 60364-5-51 erforderlich sein. ANMERKUNG 5: Für höhere Leerlauf-Ausgangsspannungen sind zusätzliche Anforderungen erforderlich, dieser Abschnitt kann aber als Leitlinie verwendet werden.
| DocumentType |
Standard
|
| PublisherName |
Verband Deutscher Elektrotechniker
|
| Status |
Withdrawn
|
| Standards | Relationship |
| DIN EN 61558-2-17 : 1998 | Identical |
| EN 61558-2-17:1997 | Identical |
| IEC 61558-2-17:1997 | Identical |
| DIN EN 61558-2-17 : 1998 | Corresponds |
| IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
| IEC 60906-3:1994 | IEC System of plugs and socket-outlets for household and similar purposes - Part 3: SELV plugs and socket-outlets, 16 A 6V, 12 V, 24 V, 48 V, a.c. and d.c. |
| EN 60998-1:2004 | Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General requirements |
| IEC 60998-1:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General requirements |
| IEC 60738-1:2006+AMD1:2009 CSV | Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification |
| EN 60998-2-2:2004 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
| IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
| IEC 60898:1995 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations |
| HD 214 : 200S2 | RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS |
| EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
| HD 384.4.41 S2:1996/A1:2002 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK |
| IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
| HD 366 : 200S1 | CLASSIFICATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT WITH REGARD TO PROTECTION AGAINST ELECTRIC SHOCK |
| IEC 60068-2-63:1991 | Environmental testing - Part 2: Test methods - Test Eg: Impact, spring hammer. |
| EN 60695-2-1-1 : 1996 | FIRE HAZARD TESTING - TEST METHODS - GLOW-WIRE END-PRODUCT TEST AND GUIDANCE |
| IEC 60884-1:2002+AMD1:2006+AMD2:2013 CSV | Plugs and socket-outlets for household and similar purposes - Part1: General requirements |
| EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
| EN 61000-3-3:2013 | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current |
| IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
| HD 625.1 : 200S1 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PRINCIPLES, REQUIREMENTS AND TESTS |
| IEC 60269-2:2013+AMD1:2016 CSV | Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K |
| VDE 0570-1 : 2006 AMD 1 2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
| EN 60998-2-1:2004 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units |
| EN 60691:2016 | Thermal-links - Requirements and application guide |
| ISO 3:1973 | Preferred numbers — Series of preferred numbers |
| IEC 60695-2-10:2000 | FIRE HAZARD TESTING - TEST METHODS - GLOW-WIRE TEST METHODS - GENERAL |
| IEC 60947-7-1:2009 | Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors |
| IEC 60269-2-1:2004 | Low-voltage fuses - Part 2-1: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Sections I to VI: Examples of types of standardized fuses |
| HD 630.3.1 S3:2002 | LOW-VOLTAGE FUSES - PART 3-1: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - SECTIONS 1 TO 4 |
| IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
| HD 601 : 200S1 | TEST PROBES TO VERIFY PROTECTION BY ENCLOSURES |
| IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
| HD 630.2.1 : 200S6 | LOW-VOLTAGE FUSES - PART 2-1: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) - SECTIONS 1 TO 5: EXAMPLES OF TYPES OF STANDARDIZED FUSES |
| IEC 60998-2-2:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
| IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
| IEC 60050-421:1990 | International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors |
| EN 60695-2-1-0 : 1996 | FIRE HAZARD TESTING - TEST METHODS - GLOW-WIRE TEST METHODS - GENERAL |
| HD 566 : 200S1 | THERMAL EVALUATION AND CLASSIFICATION OF ELECTRICAL INSULATION |
| IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
| IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
| IEC 60269-3:2010+AMD1:2013 CSV | Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F |
| HD 323.2.6 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST FC AND GUIDANCE: VIBRATION (SINUSOIDAL) |
| IEC 60076-1:2011 | Power transformers - Part 1: General |
| IEC 60691:2015 | Thermal-links - Requirements and application guide |
| IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
| IEC 60906-1:2009 | IEC system of plugs and socket-outlets for household and similar purposes - Part 1: Plugs and socket-outlets 16 A 250 V a.c. |
| EN 60269-3:1995/A1:2003 | LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) |
| IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
| EN 60269-2:1995/A2:2002 | LOW-VOLTAGE FUSES - SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) |
| EN 60076-1:2011 | Power transformers - Part 1: General |
| EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
| ISO 4046:1978 | Paper, board, pulp and related terms — Vocabulary |
| DIN EN 61558-1 : 2006 AMD 1 2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
| HD 193 : 200S2 | VOLTAGE BANDS FOR ELECTRICAL INSTALLATIONS OF BUILDINGS |
| EN 61058-1:2002/A2:2008 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
| IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
| IEC 60884-2-4:2007 | Plugs and socket-outlets for household and similar purposes - Part 2-4: Particular requirements for plugs and socket-outlets for SELV |
| EN 60999-1:2000 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) |
| HD 441 : 200S1 | METHODS OF TEST FOR THE DETERMINATION OF THE FLAMMABILITY OF SOLID ELECTRICAL INSULATING MATERIALS WHEN EXPOSED TO AN IGNITING SOURCE |
| EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
| IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
| EN 60068-2-32:1993 | Basic environmental testing procedures - Part 2: Tests - Test Ed: Free fall |
| EN 60947-7-1:2009 | Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors |
| HD 625.3 : 200S1 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 3: USE OF COATINGS TO ACHIEVE INSULATION COORDINATION OF PRINTED BOARD ASSEMBLIES |
| IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
| HD 384.5.51 : 200S2 | ELECTRICAL INSTALLATION OF BUILDINGS - PART 5: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - CHAPTER 51: COMMON RULES |
| HD 243 : S12 | GRAPHICAL SYMBOLS FOR USE ON EQUIPMENT - INDEX, SURVEY AND COMPILATION OF THE SINGLE SHEETS |
| IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
| EN 60068-2-63 : 1994 | ENVIRONMENTAL TESTING - PART 2: TEST METHODS - TEST EG: IMPACT, SPRING HAMMER |
| IEC 60998-2-1:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units |
| IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
| EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
| IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |