• VDE 0750-2-40 : 1998

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    MEDICAL ELECTRICAL EQUIPMENT - PART 2-40: PARTICULAR REQUIREMENTS FOR THE SAFETY OF ELECTROMYOGRAPHS AND EVOKED RESPONSE EQUIPMENT

    Available format(s): 

    Superseded date:  14-11-2022

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Verband Deutscher Elektrotechniker

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Einführung
    HAUPTABSCHNITT EINS - ALLGEMEINES
    1 Anwendungsbereich und Zweck
    2 Begriffe und Definitionen
    5 Klassifikation
    6 Bezeichnungen, Aufschriften und Begleitpapiere
    7 Strom- bzw. Leistungsaufnahme
    HAUPTABSCHNITT ZWEI - UMWELTBEDINGUNGEN
    HAUPTABSCHNITT DREI - SCHUTZ GEGEN DIE GEFAHR EINES
    ELEKTRISCHEN SCHLAGES
    14 Anforderungen in bezug auf die Einteilung der
       Geräte
    20 Spannungsfestigkeit
    HAUPTABSCHNITT VIER - SCHUTZ GEGEN MECHANISCHE GEFÄHRDUNG
    HAUPTABSCHNITT FÜNF - SCHUTZ GEGEN GEFAHREN DURCH
    UNERWÜNSCHTE ODER ÜBERMÄSSIGE STRAHLUNG
    36 Elektromagnetische Verträglichkeit
    HAUPTABSCHNITT SECHS - SCHUTZ GEGEN GEFAHREN DURCH ZÜNDUNG
    BRENNBARER GEMISCHE
    HAUPTABSCHNITT SIEBEN - SCHUTZ GEGEN ÜBERMÄSSIGE TEMPERATUREN
    UND ANDERE GEFÄHRDUNGEN
    42 Übermässige Temperaturen
    46 Menschliches Versagen
    HAUPTABSCHNITT ACHT - GENAUIGKEIT DER BETRIEBSDATEN UND
    SCHUTZ GEGEN GEFÄHRDENDE AUSGANGSWERTE
    50 Genauigkeit der Betriebsdaten
    51 Schutz gegen gefährdende Ausgangswerte
    HAUPTABSCHNITT NEUN - NICHT BESTIMMUNGSGEMÄSSER BETRIEB UND
    FEHLERFÄLLE; UMWELTPRÜFUNGEN
    HAUPTABSCHNITT ZEHN - KONSTRUKTIVE ANFORDERUNGEN
    Anhang AA (informativ) Allgemeine Erklärung und
              Begründung
    Anhang ZA (normativ) Normative Verweisungen
              auf Internationale Publikationen mit ihren
              entsprechenden Europäischen Publikationen
    Anhang ZB (informativ) Andere in dieser Norm
              zitierte Internationale Publikationen mit den
              Verweisungen auf die entsprechenden Europäischen
              Publikationen

    Abstract - (Show below) - (Hide below)

    Diese Besonderen Festlegungen gelten für ELEKTROMYOGRAPHEN, wie in 2.101 definiert und GERÄTE FÜR EVOZIERTE POTENTIALE, wie in 2.1.102 definiert, nachfolgend als GERÄTE bezeichnet. Der Zweck dieser Besonderen Festlegungen ist es, besondere Anforderungen für die Sicherheit von ELEKTROMYOGRAPHEN und GERÄTEN FÜR EVOZIERTE POTENTIALE, wie In 2.1.101 beziehungsweise 2.1.102 definiert, festzulegen.

    General Product Information - (Show below) - (Hide below)

    Development Note DRAFT 2015 issued in September 2015. (09/2015)
    Document Type Standard
    Publisher Verband Deutscher Elektrotechniker
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60645-3:2007 Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration
    IEC 60645-3:2007 Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration
    EN 60825-1:2014/AC:2017-06 SAFETY OF LASER PRODUCTS - PART 1: EQUIPMENT CLASSIFICATION AND REQUIREMENTS (IEC 60825-1:2014)
    DIN EN 60601-1-1 : 2002 MEDICAL ELECTRICAL EQUIPMENT - PART 1-1: GENERAL REQUIREMENTS FOR SAFETY - COLLATERAL STANDARD: SAFETY REQUIREMENTS FOR MEDICAL ELECTRICAL SYSTEMS
    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    VDE 0750-1-2 : 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 1-2: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: ELECTROMAGNETIC DISTURBANCES REQUIREMENTS AND TESTS (IEC 60601-1-2:2014)
    IEC 60825-1:2014 Safety of laser products - Part 1: Equipment classification and requirements
    EN 60601-1-1:2001 Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems
    IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    DIN EN 60825-1 : 2015-07 SAFETY OF LASER PRODUCTS - PART 1: EQUIPMENT CLASSIFICATION AND REQUIREMENTS (IEC 60825-1:2014)
    VDE 0750-1-1 : 2002 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR SAFETY; 1 COLLATERAL STANDARD: SAFETY REQUIREMENTS FOR MEDICAL ELECTRICAL SYSTEMS
    VDE 0837-1 : 2015-07 SAFETY OF LASER PRODUCTS - PART 1: EQUIPMENT CLASSIFICATION AND REQUIREMENT (IEC 60825-1:2014)
    VDE 0750-1 : 2013 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005 + COR.:2006 + COR.:2007 + A1:2012)
    IEC 60601-1-1:2000 Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems
    DIN EN 60645-3:2008-01 Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration (IEC 60645-3:2007); German version EN 60645-3:2007
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective