Preliminary note
Introduction
1. Scope
2. Principle of the method
3. Mode of operation
4. Features of the methods
5. Example of a Condensation Particle Counter
6. Specific requirements
7. Functional test and calibration
8. Measurement planning
9. Preparations and procedure
10. Data documentation
11. Instrument parameters
12. Interferences and sources of error
13. Maintenance.
14. Examples of applications
Annex - Results of comparative measurements on the
counting efficiency at the lower detection limit
Bibliography
This guideline reviews the measurement of the particle number concentration in ambient air with Condensation Particle Counters and describes the principle on which the method is based.
DevelopmentNote |
Superesdes VDI 3489-2. (04/2010)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
Verlag des Vereins Deutscher Ingenieure
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
VDI 4300 Blatt 11:2013-12 | Measurement of indoor air pollution - Measurement strategies for determination of airborne particles in indoor environment - PM-fraction |
BS EN 16897:2017 | Workplace exposure. Characterization of ultrafine aerosols/nanoaerosols. Determination of number concentration using condensation particle counters |
DIN EN 12341:1999-03 | AMBIENT AIR - STANDARD GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM[10] OR PM[2],[5] MASS CONCENTRATION OF SUSPENDED PARTICULATE MATTER |
VDI 3867 Blatt 5:2013-11 | Measurement of particles in ambient air - Determination of the particle number concentration and particle size distribution of aerosols - Time-of-flight spectrometer |
VDI 3867 Blatt 3:2012-08 | Measurement of particles in ambient air - Determination of the particle number concentration and number size distribution of aerosols - Electrical mobility spectrometer |
VDI 3867 Blatt 6:2012-12 | Measurement of particles in ambient air - Determination of the particle number concentration and number size distribution of aerosols - Electrical Low Pressure Impactor (ELPI) |
VDI 3871:2016-12 (Draft) | Measurement of particles in ambient air - Electrical aerosol monitors based on diffusion charging |
DIN EN 12341:2014-08 | Ambient air - Standard gravimetric measurement method for the determination of the PM or PM mass concentration of suspended particulate matter |
VDI 3491 Blatt 1:2016-07 | Measurement of particles - Methods for generating test aerosols - Principles and overview |
DIN EN 16897:2015-09 (Draft) | WORKPLACE EXPOSURE - CHARACTERIZATION OF ULTRAFINE AEROSOLS/NANOAEROSOLS - DETERMINATION OF NUMBER CONCENTRATION USING CONDENSATION PARTICLE COUNTERS |
DIN EN 16897:2017-09 | WORKPLACE EXPOSURE - CHARACTERIZATION OF ULTRAFINE AEROSOLS/NANOAEROSOLS - DETERMINATION OF NUMBER CONCENTRATION USING CONDENSATION PARTICLE COUNTERS |
VDI 3867 Blatt 4:2011-06 | Measurement of particles in ambient air - Determination of the particle number concentration and particle size distribution of aerosols - Optical aerosol spectrometer |
DIN EN 16450:2015-10 (Draft) | AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5) |
EN 16897:2017 | Workplace exposure - Characterization of ultrafine aerosols/nanoaerosols - Determination of number concentration using condensation particle counters |
S.R. EN 16897:2017 | WORKPLACE EXPOSURE - CHARACTERIZATION OF ULTRAFINE AEROSOLS/NANOAEROSOLS - DETERMINATION OF NUMBER CONCENTRATION USING CONDENSATION PARTICLE COUNTERS |
VDI 4280 Blatt 2:2000-12 | Planning of ambient air quality measurements - Rules for planning investigations of traffic related air pollutants in key pollution areas |
VDI 1000:2017-02 | VDI Standardisation Work - Principles and procedures |
VDI 3867 Blatt 6:2012-12 | Measurement of particles in ambient air - Determination of the particle number concentration and number size distribution of aerosols - Electrical Low Pressure Impactor (ELPI) |
VDI 3867 Blatt 5:2013-11 | Measurement of particles in ambient air - Determination of the particle number concentration and particle size distribution of aerosols - Time-of-flight spectrometer |
VDI 3867 Blatt 3:2012-08 | Measurement of particles in ambient air - Determination of the particle number concentration and number size distribution of aerosols - Electrical mobility spectrometer |
VDI 3867 Blatt 4:2011-06 | Measurement of particles in ambient air - Determination of the particle number concentration and particle size distribution of aerosols - Optical aerosol spectrometer |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.