• IEC 61241-11:2005

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electrical apparatus for use in the presence of combustible dust - Part 11: Protection by intrinsic safety 'iD'

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2011

    Language(s): 

    Published date:  24-10-2005

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Grouping and classification of intrinsically safe
       apparatus and associated apparatus
    5 Categories of electrical apparatus
    6 Apparatus construction
       6.1 Enclosures
       6.2 Temperatures of apparatus immersed in dust
       6.3 Facilities for connection of external circuits
       6.4 Separation distances
       6.5 Protection against polarity reversal
       6.6 Earth conductors, connections and terminals
       6.7 Encapsulation used for exclusion of potentially
             explosive atmosphere
    7 Components on which intrinsic safety depends
       7.1 Rating of components
       7.2 Connectors for internal connections, plug-in cards
             and components
       7.3 Fuses
       7.4 Primary and secondary cells and batteries
       7.5 Semiconductors
       7.6 Failure of components and connections
       7.7 Piezo-electric devices
    8 Infallible components, infallible assemblies of components
       and infallible connections
    9 Diode safety barriers
    10 Type verifications, assessments and type tests
       10.1 Spark ignition assessment
       10.2 Temperature tests
       10.3 Voltage tests
       10.4 Small component ignition test
       10.5 Determination of parameters of loosely specified
             components
       10.6 Tests for cells and batteries
       10.7 Mechanical test
       10.8 Tests for apparatus containing piezoelectric devices
       10.9 Type tests for diode safety barriers and safety shunts
       10.10 Cable pull test
    11 Routine verifications and tests
    12 Marking
       12.1 General
       12.2 Marking of connection facilities
    13 Documentation
    Annex A (normative) See Annex B of IEC 60079-11
    Annex B (informative) See Annex C of IEC 60079-11
    Annex C (normative) See Annex D of IEC 60079-11

    Abstract - (Show below) - (Hide below)

    This part of IEC 61241 specifies requirements for the construction and testing of intrinsically safe apparatus intended for use in potentially explosive dust cloud or dust layer environments and for associated apparatus that is intended for connection to intrinsically safe circuits which enter such environments.The contents of the corrigendum of February 2006 have been included in this copy.

    General Product Information - (Show below) - (Hide below)

    Development Note To be read in conjunction with IEC 61241-0. (10/2005)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 61241-17:2005 Electrical apparatus for use in the presence of combustible dust Inspection and maintenance of electrical installations in hazardous areas (other than mines)
    BIS IS/IEC 60079-25 : 2010 EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS
    BS EN 61241-14:2004 Electrical apparatus for use in the presence of combustible dust Selection and installation
    CSA C22.2 No. 60079-25 : 2014 EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS
    UNE-EN 1127-1:2012 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology
    BS EN 61241-18:2004 Electrical apparatus for use in the presence of combustible dust Protection by encapsulation \'mD\'
    EN 60079-25:2010/AC:2013 EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS (IEC 60079-25:2010)
    EN 61241-14:2004 Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation
    EN 61241-17:2005 Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)
    I.S. EN 60079-25:2010 EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS (IEC 60079-25:2010 (EQV))
    12/30270980 DC : 0 BS EN 1127-2 - EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING
    I.S. EN 61241-14:2004 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 14: SELECTION AND INSTALLATION
    CEI EN 60079-25 : 2012 EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS
    BS EN 1127-1:2011 Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology
    DIN EN 1127-1:2011-10 EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY
    EN 60079-14:2014/AC:2016 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016)
    BIS IS/IEC 60079-18 : 2009 EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION 'M'
    VDI 2263 Blatt 7:2010-07 Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in spraying and drying integrated equipment
    BIS IS/IEC 60079-1 : 2007 EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D'
    02/204779 DC : DRAFT JULY 2002 IEC 61241-17 ED.1 - ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES)
    CSA C22.4 No. 1 : 2009(R2018) OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE
    I.S. EN 61241-17:2005 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES)
    NF EN 60079-25 : 2011 EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS
    BS EN 1127-1:2019 Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology
    I.S. EN 1127-1:2011 EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY
    EEMUA 186 : 2016 A PRACTITIONER'S HANDBOOK FOR POTENTIALLY EXPLOSIVE ATMOSPHERES
    UNE-EN 60079-14:2016 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
    IEC 61241-14:2004 Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation
    IEC 61241-17:2005 Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)
    BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
    CSA C22.4 PACKAGE : 2009 CONSISTS OF C22.4 NO. 1-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE AND C22.4 NO. 2-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE - SAFETY MANAGEMENT SYSTEM REQUIREMENTS
    UNE-EN 60079-25:2017 Explosive atmospheres -- Part 25: Intrinsically safe electrical systems
    UNI EN 1127-1 : 2011 EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY
    IEC 60079-25:2010 Explosive atmospheres - Part 25: Intrinsically safe electrical systems
    IEC 61241-18:2004 Electrical apparatus for use in the presence of combustible dust - Part 18: Protection by encapsulation 'mD'
    EN 61241-18:2004 Electrical apparatus for use in the presence of combustible dust - Part 18: Protection by encapsulation "mD"
    02/205211 DC : DRAFT JULY 2002 IEC 61241-14 ED.1 - ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 14: SELECTION AND INSTALLATION
    BS EN 60079-25:2010 Explosive atmospheres Intrinsically safe electrical systems
    11/30247086 DC : 0 BS EN 60079-1 ED. 7.0 - EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES "D"
    I.S. EN 60079-14:2014 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
    PREN 1127-2 : DRAFT 2012 EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING
    12/30269297 DC : 0 BS EN 60079-14/ED 5 - EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
    EN 1127-1:2011 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61241-0:2004 Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
    IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    IEC 61241-1:2004 Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60079-25:2010 Explosive atmospheres - Part 25: Intrinsically safe electrical systems
    IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective