09/30208451 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS EN 54-29 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 29: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE AND HEAT SENSORS
Hardcopy , PDF
30-04-2015
English
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test methods
Annex A (normative) - Smoke tunnel for
smoke response values
Annex B (normative) - Test aerosol for smoke
response value measurements
Annex C (normative) - Smoke measuring
instruments
Annex D (normative) - Heat tunnel for heat
response value
Annex E (normative) - Apparatus for dazzling test
Annex F (informative) - Apparatus for impact test
Annex G (normative) - Fire test room
Annex H (normative) - Open wood fire (TF1)
Annex I (normative) - Smouldering (pyrolysis)
wood fire (TF2)
Annex J (normative) - Glowing smouldering
cotton fire (TF3)
Annex K (normative) - Open plastics (polyurethane)
fire (TF4)
Annex L (normative) - Liquid (heptane) fire (TF5)
Annex M (normative) - Low temperature black smoke
(decalene) liquid fire (TF8)
Annex N (informative) - Information concerning the
construction of the smoke tunnel
Annex O (informative) - Construction of the heat tunnel
Annex P (informative) - Information concerning test
procedures and requirements for the response
to slowly developing fires
Annex Q (informative) - Information concerning the
construction of the measuring ionization chamber
Annex R (normative) - Additional requirements and
test methods for detectors with more than one
smoke sensor
Annex ZA (informative) - Clauses of this European
Standard addressing the provisions of the EU
Construction Products Directive (89/106/EEC)
BS EN 54-29.
Committee |
FSH/12
|
DocumentType |
Draft
|
Pages |
84
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
PREN 54-29 : DRAFT 2009 | Identical |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 54-5:2017 | Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 9001:2015 | Quality management systems — Requirements |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.