BS 6644 - SPECIFICATION FOR THE INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70 KW (NET) AND 1.8 MW (NET) (2ND AND 3RD FAMILY GASES)
Hardcopy , PDF
30-11-2011
English
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Competence and design considerations
5 Selection of boiler, materials and components
6 Installation
7 Inspection, commissioning and servicing
Annex A (informative) - Basis for the provision of
combustion and cooling air to boiler houses and
rooms in which commercial boilers are installed
Annex B (informative) - Fan diluted flues
Annex C (informative) - Checks to be carried out on
the boiler prior to commissioning
Annex D (informative) - Typical live run checks
Annex E (normative) - Combustion products analysis
Annex F (informative) - Best practice guide to the
dispersion of combustion products
Bibliography
BS 6644
Committee |
GSE/30
|
DocumentType |
Draft
|
Pages |
61
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
BS EN 656:2000 | Gas-fired central heating boilers. Type B boilers of nominal heat input exceeding 70 kW, but not exceeding 300 kW |
BS EN 15001-2:2008 | Gas infrastructure. Gas installation pipework with an operating pressure greater than 0,5 bar for industrial installations and greater than 5 bar for industrial and non-industrial installations Detailed functional requirements for commissioning, operation and maintenance |
BS EN 437 : 2003 | TEST GASES - TEST PRESSURES - APPLIANCE CATEGORIES |
BS EN ISO 10380:2012 | Pipework. Corrugated metal hoses and hose assemblies |
BS EN 676 : 2003 | AUTOMATIC FORCED DRAUGHT BURNERS FOR GASEOUS FUELS |
BS EN 13502:2002 | Chimneys. Requirements and test methods for clay/ceramic flue terminals |
BS EN 13959:2004 | Anti-pollution check valves. DN 6 to DN 250 inclusive Family E, type A, B, C, and D |
BS 5854:1980 | Code of practice for flues and flue structures in buildings |
BS EN 13077:2008 | Devices to prevent pollution by backflow of potable water. Air gap with non-circular overflow (unrestricted). Family A. Type B |
BS 6880-2:1988 | Code of practice for low temperature hot water heating systems of output greater than 45 kW Selection of equipment |
BS EN 15001-1:2009 | Gas infrastructure. Gas installation pipework with an operating pressure greater than 0,5 bar for industrial installations and greater than 5 bar for industrial and non-industrial installations Detailed functional requirements for design, materials, construction, inspection and testing |
BS EN 303-1:2017 | Heating boilers Heating boilers with forced draught burners. Terminology, general requirements, testing and marking |
BS EN 13384-1 : 2002 | CHIMNEYS - THERMAL AND FLUID DYNAMIC CALCULATION METHODS - PART 1: CHIMNEYS SERVING ONE HEATING APPLIANCE |
BS EN 13084-4:2005 | Free-standing chimneys Brick liners. Design and execution |
BS 6880-1:1988 | Code of practice for low temperature hot water heating systems of output greater than 45 kW Fundamental and design considerations |
BS EN 13084-1:2007 | Free-standing chimneys General requirements |
BS EN 14622:2005 | Devices to prevent pollution by backflow of potable water. Air gap with circular overflow (restricted). Family A, type F |
BS EN 60079-10:2003 | Electrical apparatus for explosive gas atmospheres Classification of hazardous areas |
BS EN 13076:2003 | Devices to prevent pollution by backflow of potable water. Unrestricted air gap. Family A. Type A |
BS 5885-2:1987 | Automatic gas burners Specification for packaged burners with input rating 7.5 kW up to but excluding 60 kW |
BS EN 60079-29-1:2007 | Explosive atmospheres Gas detectors. Performance requirements of detectors for flammable gases |
BS EN 13831:2007 | Closed expansion vessels with built-in diaphragm for installation in water |
BS EN 88:1991 | Pressure governors for gas appliances for inlet pressures up to 200 mbar |
BS EN 1443:2003 | Chimneys. General requirements |
BS EN 677:1998 | Gas-fired central heating boilers. Specific requirements for condensing boilers with a nominal heat input not exceeding 70 kW |
BS EN 13084-2:2007 | Free-standing chimneys Concrete chimneys |
BS EN 1856-1:2009 | Chimneys. Requirements for metal chimneys System chimney products |
BS EN 483 : 2000 | GAS-FIRED CENTRAL HEATING BOILERS - TYPE C BOILERS OF NOMINAL HEAT INPUT NOT EXCEEDING 70 KW |
BS EN 1567 : 2000 | BUILDING VALVES - WATER PRESSURE REDUCING VALVES AND COMBINATION WATER REDUCING VALVES - REQUIREMENTS AND TESTS |
BS EN 297:1994 | Gas-fired central heating boilers. Type B<sub>11</sub> and B<sub>11BS</sub> boilers fitted with atmospheric burners of nominal heat input not exceeding 70 kW |
BS EN 1856-2:2009 | Chimneys. Requirements for metal chimneys Metal flue liners and connecting flue pipes |
BS EN 12828 : 2012 | HEATING SYSTEMS IN BUILDINGS - DESIGN FOR WATER-BASED HEATING SYSTEMS |
PD CEN/TR 1749:2014 | European scheme for the classification of gas appliances according to the method of evacuation of the combustion products (types) |
BS EN 1993-3-2:2006 | Eurocode 3. Design of steel structures Towers, masts and chimneys |
BS EN ISO 4126-1 : 2013 | SAFETY DEVICES FOR PROTECTION AGAINST EXCESSIVE PRESSURE - PART 1: SAFETY VALVES (ISO 4126-1:2013) |
BS EN 303-3:1999 | Heating boilers Gas-fired central heating boilers. Assembly comprising a boiler body and a forced draught burner |
1990/396/EEC : 1990 | COUNCIL DIRECTIVE OF 29 JUNE 1990 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO APPLIANCES BURNING GASEOUS FUELS |