15/30298489 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS EN 50124-1 - RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
Hardcopy , PDF
31-03-2017
English
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Basis for insulation coordination
5 Requirements and dimensioning rules
for clearances
6 Dimensioning rules for creepage distances
7 Tests and measurements
8 Specific requirements for applications
in the railway field
Annex A (normative) - Tables
Annex B (normative) - Provisions for type and
routine dielectric tests for equipment
Annex C (normative) - Methods of measuring
creepage distances and clearances
Annex D (normative) - Correlation between U[n] and U[Nm]
Annex E (informative) - Macro-environmental conditions
Annex F (informative) - Application guide
Bibliography
BS EN 50124-1.
Committee |
GEL/9
|
DocumentType |
Draft
|
Pages |
53
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
PREN 50124-1 : DRAFT 2015 | Identical |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60383-1:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria |
EN 50153 : 2014 AMD 1 2017 | RAILWAY APPLICATIONS - ROLLING STOCK - PROTECTIVE PROVISIONS RELATING TO ELECTRICAL HAZARDS |
IEC 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC 60660:1999 | Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 000 V up to but not including 300 kV |
EN 60660:1999 | Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 kV up to but not including 300 kV |
EN 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
EN 60383-1:1996/A11:1999 | INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC OR GLASS INSULATOR UNITS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
EN 60099-1:1994/A1:1999 | SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
EN 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
EN 60507:2014 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
EN 61936-1 : 2010 AMD 1 2014 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014) |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 50129 : 2003 COR 2010 | RAILWAY APPLICATIONS - COMMUNICATION, SIGNALLING AND PROCESSING SYSTEMS - SAFETY RELATED ELECTRONIC SYSTEMS FOR SIGNALLING |
IEC 60099-1:1991+AMD1:1999 CSV | Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
EN 60071-2:1997 | Insulation co-ordination - Part 2: Application guide |
EN 60168:1994/A2:2000 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1KV |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
EN 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
EN 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 60077-1:2017 | Railway applications - Electric equipment for rolling stock - Part 1: General service conditions and general rules |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60664-3:2017 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 60383-2:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
EN 60383-2:1995 | Insulators for overhead lines with a nominal voltage above 1 kV - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
IEC 60168:1994+AMD1:1997+AMD2:2000 CSV | Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V |