15/30301829 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE
Hardcopy , PDF
31-10-2015
English
Foreword
Section 1: General
1 Scope
2 Normative references
3 Terms and definitions
4 General recommendations and background
Section 2: Designing means of escape
5 Genera
6 Means of escape and provision for rescue from houses
7 Means of escape from flats and maisonettes
8 Means of escape from special housing
9 Internal planning of flats
Section 3: Active fire protection
10 Fire detection and alarm systems
11 Fire suppression systems
12 Manual fire-fighting equipment
13 Special risk protection
14 Smoke control
15 Power supplies, cabling and installation
Section 4: Design for construction
16 Fire resistance
17 Compartmentation
18 External fire spread and building separation
19 Concealed spaces
20 Materials
21 Service ducts, pipes and shafts
22 Glazed fire-resisting elements
23 Active fire curtain/barrier assemblies
24 Openings
25 Floors and ramps on escape routes
26 Design and construction of common stairs
Section 5: Stairs and final exits
27 Number and siting of common stairs
28 Width of common stairs
29 Enclosure of common stairs
30 Basement stairs
31 Stairs within mixed-use developments
32 Access lobbies and corridors to protected stairways
33 External stairs
34 Discharge from common stairs and final exits
Section 6: Mechanical systems for ducted heating,
ventilation and air conditioning (HVAC)
35 HVAC systems within individual dwellings
36 HVAC systems serving the whole building or interconnecting
dwellings and other residential units
Section 7: Ancillary accommodation to flats and
maisonettes
37 Ancillary accommodation
38 Installation of engineering services
39 Engineering service installation rooms
40 Gas services, installation and service pipes
41 Electrical services
42 Gas and electricity meters
43 Lighting
44 Lift machine rooms and machinery spaces
45 Communal heating, ventilation and air conditioning systems
46 Refuse storage, disposal and incineration
47 Car parks and domestic garages
Section 8: Access and facilities for fire-fighting
48 General recommendations for fire-fighting facilities
49 Fire-fighting access
50 Water supplies for fire and rescue service fire-fighting use
51 Information for fire and rescue service use
Section 9: Management
52 Management of special housing
53 Evacuation of disabled occupants or occupants that require
assistance to escape
54 Residents
55 Caretakers
56 Maintenance of fire protection measures
57 Maintenance of building plant and equipment
58 Ensuring that systems respond properly in an emergency
Section 10: Building works: Material alterations, extensions,
refurbishment, change of use, disuse, decommissioning
and demolition
59 Design of works
60 Change of use
61 Refurbishments
62 Dwellings in disuse and areas decommissioned
63 Managing building work and material alterations
64 Building works to occupied or partly occupied buildings
Annexes
Annex A (informative) - Methods of smoke control
Annex B (informative) - Assessing the level of fire precautions for
special housing
Annex C (normative) - Additional recommendations for property
and business continuity protection
Annex D (normative) - Atria
Annex E (normative) - Private balconies (open or enclosed) and
communal roof gardens
Annex F (informative) - Management of additional needs and disabilities
Annex G (informative) - Advice to occupiers of dwellings in residential
buildings
Bibliography
BS 9991.
Committee |
FSH/14
|
DocumentType |
Draft
|
Pages |
176
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
BS 5234-2:1992 | Partitions (including matching linings) Specification for performance requirements for strength and robustness including methods of test |
BS 8414-1:2002 | Fire performance of external cladding systems Test methods for non-loadbearing external cladding systems applied to the face of a building |
BS 5266-1:2011 | Emergency lighting Code of practice for the emergency escape lighting of premises |
BS 8414-2:2005 | Fire performance of external cladding systems Test method for non-loadbearing external cladding systems fixed to and supported by a structural steel frame |
BS 5234-1:1992 | Partitions (including matching linings) Code of practice for design and installation |
BS EN 1155:1997 | Building hardware. Electrically powered hold-open devices for swing doors. Requirements and test methods |
BS 5516-2:2004 | Patent glazing and sloping glazing for buildings Code of practice for sloping glazing |
BS 8524-1:2013 | Active fire curtain barrier assemblies Specification |
BS EN 1991-1-2:2002 | Eurocode 1. Actions on structures General actions. Actions on structures exposed to fire |
BS 7346-7:2013 | Components for smoke and heat control systems Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks |
BS EN ISO 1182:2010 | Reaction to fire tests for products. Non-combustibility test |
BS 9990:2015 | Non automatic fire-fighting systems in buildings. Code of practice |
BS 8524-2:2013 | Active fire curtain barrier assemblies Code of practice for application, installation and maintenance |
BS ISO 3864-1:2011 | Graphical symbols. Safety colours and safety signs Design principles for safety signs and safety markings |
DD ENV 1187:2002 | Test methods for external fire exposure to roofs |
BS EN ISO 14122-4:2016 | Safety of machinery. Permanent means of access to machinery Fixed ladders |
BS 7346-8:2013 | Components for smoke control systems Code of practice for planning, design, installation, commissioning and maintenance |
BS EN 12845:2015 | Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance |
BS EN ISO 11925-2:2010 | Reaction to fire tests. Ignitability of products subjected to direct impingement of flame Single-flame source test |
BS 8519:2010 | Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice |
BS 7157:1989 | Method of test for ignitability of fabrics used in the construction of large tented structures |
BS EN ISO 1716:2010 | Reaction to fire tests for products. Determination of the gross heat of combustion (calorific value) |
BS 9266:2013 | Design of accessible and adaptable general needs housing. Code of practice |
PD 7974-7:2003 | Application of fire safety engineering principles to the design of buildings Probabilistic risk assessment |
BS EN 13823 : 2010 | REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - BUILDING PRODUCTS EXCLUDING FLOORINGS EXPOSED TO THE THERMAL ATTACK BY A SINGLE BURNING ITEM |
PD 7974-6:2004 | The application of fire safety engineering principles to fire safety design of buildings Human factors. Life safety strategies. Occupant evacuation, behaviour and condition (Sub-system 6) |
BS 7974:2001 | Application of fire safety engineering principles to the design of buildings. Code of practice |
BS 3251:1976 | Specification. Indicator plates for fire hydrants and emergency water supplies |
BS EN 1154:1997 | Building hardware. Controlled door closing devices. Requirements and test methods |
BS 5306-8:2012 | Fire extinguishing installations and equipment on premises Selection and positioning of portable fire extinguishers. Code of practice |
BS 7273-4:2007 | Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.