• 15/30302476 DC : 0

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    BS EN 13501-2 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES

    Available format(s):  Hardcopy, PDF

    Superseded date:  31-07-2016

    Language(s):  English

    Published date: 

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    European foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Fire scenarios
    5 Resistance to fire performance characteristics
    6 Declaration of fire resistance performance
    7 Classification procedure for fire resistance
    Annex A (normative) - Classification report
    Annex B (informative) - Presentation of characterization
            data and their field of application for products
            and systems for protecting elements or parts of work
    Bibliography

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee FSH/21/-/8
    Document Type Draft
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 13381-9:2015 Test methods for determining the contribution to the fire resistance of structural members - Part 9: Applied fire protection systems to steel beams with web openings
    EN 15080-12:2011 Extended application of results from fire resistance tests - Part 12: Loadbearing masonry walls
    EN 1365-1:2012/AC:2013 FIRE RESISTANCE TESTS FOR LOADBEARING ELEMENTS - PART 1: WALLS
    EN 15254-6 : 2014 EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 6: CURTAIN WALLING
    EN 1364-3:2014 FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 3: CURTAIN WALLING - FULL CONFIGURATION (COMPLETE ASSEMBLY)
    EN 1366-5:2010 Fire resistance tests for service installations - Part 5: Service ducts and shafts
    EN 1365-3:1999 Fire resistance tests for loadbearing elements - Part 3: Beams
    EN 1364-1:1999 Fire resistance tests for non-loadbearing elements - Part 1: Walls
    EN 1634-3:2004/AC:2006 FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 3: SMOKE CONTROL TEST FOR DOOR AND SHUTTER ASSEMBLIES
    PREN 15269-6 : DRAFT 2015 EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 6: FIRE RESISTANCE OF SLIDING TIMBER DOORSETS
    EN 13216-1:2004 Chimneys - Test methods for system chimneys - Part 1: General test methods
    EN 15269-3:2012 Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 3: Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows
    EN 13381-4:2013 Test methods for determining the contribution to the fire resistance of structural members - Part 4: Applied passive protection to steel members
    ISO 13943:2017 Fire safety — Vocabulary
    EN 1366-4:2006+A1:2010 Fire resistance tests for service installations - Part 4: Linear joint seals
    EN 15269-20:2009 Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets
    EN 1994-1-2:2005/A1:2014 EUROCODE 4 - DESIGN OF COMPOSITE STEEL AND CONCRETE STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
    EN 15080-8:2009 Extended application of results from fire resistance tests - Part 8: Beams
    EN 1366-7:2004 Fire resistance tests for service installations - Part 7: Conveyor systems and their closures
    EN 13381-2:2014 Test methods for determining the contribution to the fire resistance of structural members - Part 2: Vertical protective membranes
    EN 1366-6:2004 Fire resistance tests for service installations - Part 6: Raised access and hollow core floors
    EN 15269-5:2014+A1:2016 Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 5: Fire resistance of hinged and pivoted metal framed glazed doorsets and openable windows
    EN 1366-3:2009 Fire resistance tests for service installations - Part 3: Penetration seals
    EN 13381-8:2013 Test methods for determining the contribution to the fire resistance of structural members - Part 8: Applied reactive protection to steel members
    EN 1995-1-2:2004/AC:2009 EUROCODE 5: DESIGN OF TIMBER STRUCTURES - PART 1-2: GENERAL - STRUCTURAL FIRE DESIGN
    EN 1992-1-2:2004/AC:2008 EUROCODE 2: DESIGN OF CONCRETE STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
    EN 1364-4:2014 Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration
    EN 13381-6:2012 Test methods for determining the contribution to the fire resistance of structural members - Part 6: Applied protection to concrete filled hollow steel columns
    EN 13381-5:2014 Test methods for determining the contribution to the fire resistance of structural members - Part 5: Applied protection to concrete/profiled sheet steel composite member
    EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
    EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
    EN 15269-2 : 2012 EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE OF HINGED AND PIVOTED STEEL DOORSETS
    EN 13381-3:2015 Test methods for determining the contribution to the fire resistance of structural members - Part 3: Applied protection to concrete members
    PREN 15269-11 : DRAFT 2013 EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 11: FIRE RESISTANCE OF OPERABLE FABRIC CURTAINS
    EN 13381-1:2014 Test methods for determining the contribution to the fire resistance of structural members - Part 1: Horizontal protective membranes
    EN 15269-7:2009 Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 7: Fire resistance for steel sliding doorsets
    EN 15269-1:2010 Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 1: General requirements
    EN 15882-3:2009 Extended applications of results from fire resistance tests for service installations - Part 3: Penetration seals
    EN 1996-1-2:2005/AC:2010 EUROCODE 6 - DESIGN OF MASONRY STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
    EN 1365-4:1999 Fire resistance tests for loadbearing elements - Part 4: Columns
    EN 1999-1-2:2007/AC:2009 EUROCODE 9 - DESIGN OF ALUMINIUM STRUCTURES - PART 1-2: STRUCTURAL FIRE DESIGN
    EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures
    EN 15269-10:2011 Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies including their elements of building hardware - Part 10: Fire resistance of steel rolling shutter assemblies
    EN 1993-1-2:2005/AC:2009 EUROCODE 3: DESIGN OF STEEL STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
    EN 1365-5:2004 Fire resistance tests for loadbearing elements - Part 5: Balconies and walkways
    EN 14135:2004 Coverings - Determination of fire protection ability
    EN 15254-2:2009 Extended application of results from fire resistance tests - Non-loadbearing walls - Part 2: Masonry and Gypsum Blocks
    ENV 13381-7:2002 Test methods for determining the contribution to the fire resistance of structural members - Part 7: Applied protection to timber members
    EN 15254-4:2008+A1:2011 Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4: Glazed constructions
    EN 15882-4:2012 Extended application of results from fire resistance tests for service installations - Part 4: Linear joint seals
    EN 1365-2:2014 Fire resistance tests for loadbearing elements - Part 2: Floors and roofs
    EN 15725:2010/AC:2012 EXTENDED APPLICATION REPORTS ON THE FIRE PERFORMANCE OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS
    EN 14600:2005 Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification
    EN 1365-6:2004 Fire resistance tests for loadbearing elements - Part 6: Stairs
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective