17/30347865 DC : 0
NA
Status of Standard is Unknown
BS EN 50411-3-4 - FIBRE ORGANISERS AND CLOSURES TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 3-4: FIBRE MANAGEMENT SYSTEMS, WALL BOX FOR SPLICE TO PATCHCORD CONNECTIONS, FOR CATEGORY C AND A
Hardcopy , PDF
English
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviations
5 Description
6 Variants
7 Dimensional requirements
8 Tests
9 Test report
10 Performance requirements
Annex A (informative) - Fibres details for test sample
Annex B (informative) - Sample size requirements
Annex C (informative) - Families of fibre management
systems covered in this standard
Annex D (informative) - Dimensions of M type FMS for
multiple elements and multiple ribbon
Annex E (informative) - Dimensions of S type FMS for
single circuit, single element and single
ribbon
Annex F (informative) - Adapter, plug and cable
assembly connector dimensions
Bibliography
BS EN 50411-3-4.
Committee |
GEL/86/2
|
DocumentType |
Draft
|
Pages |
47
|
PublisherName |
British Standards Institution
|
Status |
NA
|
Standards | Relationship |
PREN 50411-3-4 : DRAFT 2017 | Identical |
IEC 60794-3:2014 | Optical fibre cables - Part 3: Outdoor cables - Sectional specification |
EN 50377-7-4:2011 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 7-4: LC-PC simplex terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre with full zirconia ferrule for category C |
EN 50377-15-1:2011 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 15-1: Type MPO with 12-fibre PPS ferrules terminated on IEC 60793-2 category A1a multimode fibre for 50/125 micron multimode fibre |
EN 50377-7-3:2004 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 7-3: Type LC-APC duplex terminated on IEC 60793-2 category B1.1 singlemode fibre |
EN 61754-23:2005 | Fibre optic connector interfaces - Part 23: Type LX.5 connector family |
IEC 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
EN 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
IEC 60793-2-10:2017 | Optical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres |
EN 60794-2:2017 | Optical fibre cables - Part 2: Indoor cables - Sectional specification |
EN 60793-2-50:2016 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
IEC 61300-3-3:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss |
IEC 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
IEC 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
EN 61756-1 : 2006 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - INTERFACE STANDARD FOR FIBRE MANAGEMENT SYSTEMS - PART 1: GENERAL AND GUIDANCE |
EN 61300-3-3:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss |
IEC 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
EN 60794-3:2015 | Optical fibre cables - Part 3: Sectional specification - Outdoor cables |
IEC 61758-1:2008 | Fibre optic interconnecting devices and passive components - Interface standard for closures - Part 1: General and guidance |
EN 50377-8-2:2007 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 8-2: Type LSH-APC simplex terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, composite ferrule category C |
EN 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 50377-13-2:2011 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 13-2: Type LX.5-PC DUPLEX terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, with full zirconia ferrule category U |
IEC 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
EN 50377-8-13:2010 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 8-13: Type LSH-PC simplex terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre with titanium composite ferrule for category U |
EN 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
EN 60793-2-10:2017 | Optical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres |
EN 50377-8-3:2007 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 8-3: LSH-PC simplex terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, composite ferrule category C |
IEC 61300-2-26:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist |
IEC 61754-28:2012 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 28: Type LF3 connector family |
EN 50377-16-1:2011 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 16-1: Type LF3 APC simplex terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre with titanium composite ferrule for category C |
EN 61300-2-33:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-33: Tests - Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures |
IEC 60794-5:2014 | Optical fibre cables - Part 5: Sectional specification - Microduct cabling for installation by blowing |
EN 61754-4:2013/AC:2014 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - FIBRE OPTIC CONNECTOR INTERFACES - PART 4: TYPE SC CONNECTOR FAMILY (IEC 61754-4:2013) |
EN 61300-2-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 61300-3-1:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60754-1:2014 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
EN 50377-4-4:2011 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 4-4: Type SC-PC simplex terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, with full zirconia ferrule category U |
EN 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 61300-2-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures |
EN 50377-7-1:2004 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 7-1: Type LC-PC duplex terminated on IEC 60793-2 category A1a and A1b multimode fibre |
EN 61300-2-4:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 50377-8-12:2010 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 8-12: Type LSH-APC simplex terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre with titanium composite ferrule for category U |
EN 60794-5:2016 | Optical fibre cables - Part 5: Sectional specification - Microduct cabling for installation by blowing |
IEC 61754-23:2005 | Fibre optic connector interfaces - Part 23: Type LX.5 connector family |
EN 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
IEC 60793-2-50:2015 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
IEC 61300-2-33:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-33: Tests - Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures |
IEC 60794-2:2017 | Optical fibre cables - Part 2: Indoor cables - Sectional specification |
IEC 61756-1:2006 | Fibre optic interconnecting devices and passive components - Interface standard for fibre management systems - Part 1: General and guidance |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 61754-15:2009 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 15: Type LSH connector family |
IEC 61754-20:2012 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 20: Type LC connector family |
EN 61754-15:2009/AC:2014 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - FIBRE OPTIC CONNECTOR INTERFACES - PART 15: TYPE LSH CONNECTOR FAMILY (IEC 61754-15:2009) |
IEC 61754-4:2013 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 4: Type SC connector family |
EN 50377-4-2:2011 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 4-2: Type SC/APC simplex 8° terminated on IEC 60793-2-50 of types B1.1 and B1.3 singlemode fibre, with full zirconia ferrule category U |
EN 50377-13-3:2011 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 13-3: Type LX.5-APC DUPLEX terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, with full zirconia ferrule category U |
EN 61754-28:2012 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 28: Type LF3 connector family |
EN 61754-7:2008 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 7: Type MPO connector family |
IEC 61754-7:2008 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 7: Type MPO connector family |
EN 61300-2-26:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist |
EN 50377-7-2:2004 | Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 7-2: LC-PC duplex terminated on IEC 60793-2 category B1.1 singlemode fibre |
IEC 61300-3-1:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination |
EN 61754-20:2012 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 20: Type LC connector family |
EN 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
EN 61758-1:2008 | Fibre optic interconnecting devices and passive components - Interface standard for closures - Part 1: General and guidance |