• Shopping Cart
    There are no items in your cart

EN 61300-3-3:2009

Current

Current

The latest, up-to-date edition.

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss

Published date

06-05-2009

Sorry this product is not available in your region.
Summarise this standard

FOREWORD
1 Scope
2 Normative references
3 General description
  3.1 Test method
  3.2 Precautions
4 Apparatus
  4.1 Methods 1, 2 and 3
      4.1.1 General
      4.1.2 Source (S)
      4.1.3 Launch condition (E)
      4.1.4 Monitoring equipment
      4.1.5 Detector D
      4.1.6 Stress fixture
      4.1.7 Branching device BD
      4.1.8 Temporary joints
      4.1.9 Data acquisition
      4.1.10 Monitor sample
      4.1.11 Reference fibre
  4.2 Methods 4 and 5
      4.2.1 General
      4.2.2 OTDR
      4.2.3 Buffer fibre
      4.2.4 Optical switches
5 Procedure
  5.1 Monitoring attenuation and return loss of a single
      sample - method 1
      5.1.1 General
      5.1.2 Attenuation monitoring - method 1
      5.1.3 Return loss monitoring - method 1
  5.2 Monitoring attenuation and return loss of multiple
      samples using a 1 x N branching device -
      method 2
      5.2.1 General
      5.2.2 Attenuation monitoring - method 2
      5.2.3 Return loss monitoring - method 2
  5.3 Monitoring attenuation and return loss of multiple
      samples using two 1 x N optical switches -
      method 3
      5.3.1 General
      5.3.2 Attenuation - method 3
      5.3.3 Return loss - method 3
  5.4 Bidirectional OTDR monitoring of attenuation
      and return loss of multiple samples -
      method 4
      5.4.1 General
      5.4.2 Attenuation - method 4
      5.4.3 Return loss - method 4
  5.5 Unidirectional OTDR monitoring of attenuation
      and return loss of multiple samples -
      method 5
6 Details to be specified
  6.1 Method 1
  6.2 Methods 2 and 3
  6.3 Methods 4 and 5
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

IEC 61300-3-3:2009(E) describes the procedure to monitor changes in attenuation and/or return loss of a component or an interconnecting device, when subjected to an environmental or mechanical test. The procedure may be applied to measurements on single samples or to simultaneous measurements on multiple samples, both at single wavelengths and multiple wavelengths, by using branching devices and/or switches as appropriate. This edition constitutes a minor revision. The change with respect to the previous edition is the structure of the document.

Committee
CLC/TC 86BXA
DevelopmentNote
Supersedes UNE EN 61300-3-3. (04/2010)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

Sorry this product is not available in your region.