17/30363927 DC : 0
NA
Status of Standard is Unknown
BS EN 17176-3 - PLASTIC PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 3: FITTINGS
Hardcopy , PDF
English
European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Material
5 General characteristics
6 General characteristics
7 Selection of fittings
8 Mechanical characteristics of
PVC-O fittings - Resistance to hydrostatic
pressure
9 Physical characteristics
10 Sealing rings
11 Performance requirements
12 Marking
Annex A (normative) - Determination of long
term strength
Bibliography
BS EN 17176-3.
Committee |
PRI/88/2
|
DocumentType |
Draft
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
NA
|
Standards | Relationship |
PREN 17176-3 : DRAFT 2017 | Identical |
EN ISO 3126:2005 | Plastics piping systems - Plastics components - Determination of dimensions (ISO 3126:2005) |
ISO 6259-2:1997 | Thermoplastics pipes Determination of tensile properties Part 2: Pipes made of unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly (vinyl chloride) (PVC-C) and high-impact poly (vinyl chloride) (PVC-HI) |
EN 12842:2012 | Ductile iron fittings for PVC-U or PE piping systems - Requirements and test methods |
EN ISO 1452-5:2010 | Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 5: Fitness for purpose of the system (ISO 1452-5:2009, corrected version 2010-03-01) |
ISO 1167-2:2006 | Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the resistance to internal pressure — Part 2: Preparation of pipe test pieces |
EN ISO 6401:2008 | Plastics - Poly(vinyl chloride) - Determination of residual vinyl chloride monomer - Gas-chromatographic method (ISO 6401:2008) |
ISO 2507-1:1995 | Thermoplastics pipes and fittings — Vicat softening temperature — Part 1: General test method |
PREN 17176-2 : DRAFT 2017 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 2: PIPES |
ISO 1452-1:2009 | Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: General |
EN ISO 1167-2:2006 | Thermoplastics pipes, fittings and assemblies for the conveyance of fluids - Determination of the resistance to internal pressure - Part 2: Preparation of pipe test pieces (ISO 1167-2:2006) |
ISO 1452-4:2009 | Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 4: Valves |
ISO 1452-3:2009 | Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 3: Fittings |
EN ISO 1167-1:2006 | Thermoplastics pipes, fittings and assemblies for the conveyance of fluids - Determination of the resistance to internal pressure - Part 1: General method (ISO 1167-1:2006) |
ISO 161-1:1996 | Thermoplastics pipes for the conveyance of fluids Nominal outside diameters and nominal pressures Part 1: Metric series |
ISO 9080:2012 | Plastics piping and ducting systems — Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation |
ISO 1452-5:2009 | Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 5: Fitness for purpose of the system |
EN ISO 6259-1:2015 | Thermoplastics pipes - Determination of tensile properties - Part 1: General test method (ISO 6259-1:2015) |
EN ISO 9080:2012 | Plastics piping and ducting systems - Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation (ISO 9080:2012) |
EN ISO 1452-4:2009 | Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 4: Valves (ISO 1452-4:2009) |
CEN/TR 15438:2007 | Plastics piping systems - Guidance for coding of products and their intended uses |
ISO 6259-1:2015 | Thermoplastics pipes Determination of tensile properties Part 1: General test method |
ISO 3126:2005 | Plastics piping systems Plastics components Determination of dimensions |
EN ISO 1452-1:2009 | Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: General (ISO 1452-1:2009) |
EN ISO 9852:2017 | Unplasticized poly(vinyl chloride) (PVC-U) pipes - Dichloromethane resistance at specified temperature (DCMT) - Test method (ISO 9852:2007) |
ISO 1452-2:2009 | Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 2: Pipes |
ISO 18373-1:2007 | Rigid PVC pipes Differential scanning calorimetry (DSC) method Part 1: Measurement of the processing temperature |
ISO 1167-3:2007 | Thermoplastics pipes, fittings and assemblies for the conveyance of fluids Determination of the resistance to internal pressure Part 3: Preparation of components |
ISO 6401:2008 | Plastics — Poly(vinyl chloride) — Determination of residual vinyl chloride monomer — Gas-chromatographic method |
EN ISO 7686:2005 | Plastics pipes and fittings - Determination of opacity (ISO 7686:2005) |
EN ISO 1452-3:2010 | Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 3: Fittings (ISO 1452-3:2009, corrected version 2010-03-01) |
ISO/TR 4191:2014 | Plastics piping systems for water supply Unplasticized poly(vinyl chloride)(PVC-U) and oriented PVC-U (PVC-O) Guidance for installation |
PREN 17176-1 : DRAFT 2017 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 1: GENERAL |
ISO 9852:2007 | Unplasticized poly(vinyl chloride) (PVC-U) pipes — Dichloromethane resistance at specified temperature (DCMT) — Test method |
EN ISO 1452-2:2009 | Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Pipes (ISO 1452-2:2009) |
EN ISO 1183-1:2012 | Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method (ISO 1183-1:2012) |
ISO 7686:2005 | Plastics pipes and fittings — Determination of opacity |
EN ISO 1167-3:2007 | Thermoplastics pipes, fittings and assemblies for the conveyance of fluids - Determination of the resistance to internal pressure - Part 3: Preparation of components (ISO 1167-3:2007) |
ISO 1167-1:2006 | Thermoplastics pipes, fittings and assemblies for the conveyance of fluids Determination of the resistance to internal pressure Part 1: General method |
PREN 17176-5 : DRAFT 2017 | PLASTIC PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.