99/561983 DC : APR 99
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ISO/DIS 14257 - ACOUSTICS - MEASUREMENT AND MODELLING OF SPATIAL SOUND DISTRIBUTION CURVES IN WORKROOMS FOR EVALUATION OF THEIR ACOUSTICAL PERFORMANCE
14-11-2001
23-11-2012
1 Scope
2 Normative references
3 Terms and definitions
4 Sound distribution in a room
4.1 General
4.2 Spatial sound distribution curves
4.2.1 Reference spatial sound distribution
curves
4.2.2 Spatial sound distribution curves in
frequency bands and for a given
frequency spectrum
4.2.3 Frequency-normalized spatial sound
distribution curve C
5 Measurement of the spatial sound distribution curve
5.1 Specifications regarding the sound source used
for the test
5.1.1 Performance requirements to be met by the
source
5.1.2 Calibration and verification of the sound
output of the source
5.1.3 Location of the source
5.1.4 Sound output versus background noise
5.1.5 Verification of a spatial sound
distribution curve
5.2 Measurement instrumentation
5.3 Measurement path and points
5.3.1 Measurement path
5.3.2 Measurement points
5.4 Measurement procedure
5.5 Representation of the measured data
5.6 Factors influencing the measurement results
6 Modelling of the measured spatial sound distribution
curve in view of the evaluation of the acoustical
performance of workrooms
6.1 Distance ranges
6.2 Determination of the rate of spatial decay of
sound pressure levels per distance doubling.DL2
6.3 Determination of the excess of sound pressure level
with respect to a reference sound distribution
curve, DLf
6.3.1 Value of the excess of sound pressure
level over a distance range [rn,rm]
and in a given octave band
6.3.2 Value of DLf'r of DLf at a specified
distance r and for a given octave band
6.4 Evaluation of the measured data
7 Information to be recorded and reported
Annex A (normative) Performance requirements for the
sound source to be used for the test
Annex B (informative) Example of use of this International
Standard
Bibliography
Defines a procedure for measurement of the spatial sound distributiojn curve(s) of a specified workroom. Gives a procedure for determination from measured data, two descriptors of the acoustical performance of a workroom, that is the excess of sound pressure level regarding a free field and the sound pressure level decay per distance doubling.
Committee |
EH/1/4
|
DocumentType |
Draft
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
ISO 3744:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane |
ISO 6926:2016 | Acoustics Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels |
ISO 3741:2010 | Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for reverberation test rooms |
ISO 3745:2012 | Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for anechoic rooms and hemi-anechoic rooms |
IEC 61260:1995 | Electroacoustics - Octave-band and fractional-octave-band filters |
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV | Sound level meters |
IEC 60804:2000 | Integrating-averaging sound level meters |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.