AAMI IEC 60601-2-50 : 2009
Current
The latest, up-to-date edition.
MEDICAL ELECTRICAL EQUIPMENT - PART 2-50: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF INFANT PHOTOTHERAPY EQUIPMENT
Hardcopy , PDF
English
01-01-2009
Glossary of equivalent standards
Committee representation
Background of ANSI/AAMI adoption of Amendment 1
to IEC 60601-2-50:2009
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of
ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME
SYSTEMS
201.7 ME EQUIPMENT identification, marking
and documents
201.8 Protection against electrical HAZARDS from
ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of
ME EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive
radiation HAZARDS
201.11 Protection against excessive temperatures
and other HAZARDS
201.12 Accuracy of controls and instruments and
protection against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT
and ME SYSTEMS
202 Electromagnetic compatibility
Annexes
Annex AA (informative) - Particular guidance and rationale
Bibliography
Index of defined terms used in this particular standard
Pertains to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT PHOTOTHERAPY EQUIPMENT, as defined in 201.3.203 of this standard, also referred to as ME EQUIPMENT.
DocumentType |
Standard
|
Pages |
90
|
ProductNote |
NEW CHILD A1 IS NOW ADDED.
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Current
|
Standards | Relationship |
IEC 60601-2-50:2009+AMD1:2016 CSV | Identical |
IEC 60601-2-21:2009+AMD1:2016 CSV | Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers |
IEC 60601-2-19:2009+AMD1:2016 CSV | Medical electrical equipment - Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators |
IEC 60335-2-27:2009+AMD1:2012+AMD2:2015 CSV | Household and similar electrical appliances - Safety - Part 2-27: Particular requirements for appliances for skin exposure to optical radiation |
IEC 60050-845:1987 | International Electrotechnical Vocabulary (IEV) - Part 845: Lighting |
IEC 60601-2-20:2009+AMD1:2016 CSV | Medical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performance of infant transportincubators |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
ISO 3743-1:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for small movable sources in reverberant fields Part 1: Comparison method for a hard-walled test room |