AAMI ISO 17665-1 : 2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
STERILIZATION OF HEALTH CARE PRODUCTS - MOIST HEAT - PART 1: REQUIREMENTS FOR THE DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES
Hardcopy , PDF
01-09-2021
English
01-01-2013
Glossary of equivalent standards
Committee representation
Background of AAMI Adoption of ISO 17665-1:2006
Foreword
Introduction
1 Scope
1.1 Inclusions
1.2 Exclusions
2 Normative references
3 Terms and definitions
4 Quality management system elements
4.1 Documentation
4.2 Management responsibility
4.3 Product realization
4.4 Measurement, analysis and improvement - Control
of non-conforming product
5 Sterilizing agent characterization
5.1 Sterilizing agent
5.2 Microbicidal effectiveness
5.3 Materials effects
5.4 Environmental consideration
6 Process and equipment characterization
6.1 Process
6.1.1 General
6.1.2 Saturated steam process
6.1.3 Contained product processes
6.2 Equipment
7 Product definition
8 Process definition
9 Validation
9.1 General
9.2 Installation qualification (IQ)
9.2.1 Equipment
9.2.2 Installation
9.2.3 Function
9.3 Operational qualification (OQ)
9.4 Performance qualification (PQ)
9.5 Review and approval of validation
10 Routine monitoring and control
11 Product release from sterilization
12 Maintaining process effectiveness
12.1 Demonstration of continued effectiveness
12.2 Recalibration
12.3 Maintenance of equipment
12.4 Requalification
Annex A (informative) - Guidance
Annex B (informative) - Process definition based on
inactivation of the microbial
population in its natural state
(bioburden-based method)
Annex C (informative) - Process definition based on the
inactivation of a reference
microorganism and a knowledge of
bioburden on product items to be
sterilized (combined bioburden/biological
indicator based method
Annex D (informative) - Conservative process definition
based on inactivation of reference
microorganisms (overkill method)
Annex E (informative) - Operating cycles
Bibliography
Describes requirements for the development, validation and routine control of a moist heat sterilization process for medical devices.
Committee |
WG 03
|
DevelopmentNote |
Supersedes AAMI ISO 11134 (05/2006)
|
DocumentType |
Standard
|
Pages |
57
|
ProductNote |
Reconfirmed 2006
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ISO 17665-1:2006 | Identical |
IEC 61010-2-040:2015 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials |
EN 12442-3 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 3: VALIDATION OF THE ELIMINATION AND/OR INACTIVATION OF VIRUSES AND TRANSMISSIBLE AGENTS |
ISO 15883-1:2006 | Washer-disinfectors Part 1: General requirements, terms and definitions and tests |
ISO 11607-2:2006 | Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes |
ISO 11138-3:2017 | Sterilization of health care products — Biological indicators — Part 3: Biological indicators for moist heat sterilization processes |
ISO 15882:2008 | Sterilization of health care products — Chemical indicators — Guidance for selection, use and interpretation of results |
EN 285:2015 | Sterilization - Steam sterilizers - Large sterilizers |
ISO 11737-2:2009 | Sterilization of medical devices Microbiological methods Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process |
ISO 11737-1:2006 | Sterilization of medical devices Microbiological methods Part 1: Determination of a population of microorganisms on products |
EN 868-5:2009 | Packaging for terminally sterilized medical devices - Part 5: Sealable pouches and reels of porous materials and plastic film construction - Requirements and test methods |
EN 868-4:2017 | Packaging for terminally sterilized medical devices - Part 4: Paper bags - Requirements and test methods |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
EN 868-1 : 1997 | PACKAGING MATERIALS AND SYSTEMS FOR MEDICAL DEVICES WHICH ARE TO BE STERILIZED - GENERAL REQUIREMENTS AND TEST METHODS |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
ISO 11140-3:2007 | Sterilization of health care products — Chemical indicators — Part 3: Class 2 indicator systems for use in the Bowie and Dick-type steam penetration test |
ISO 22442-1:2015 | Medical devices utilizing animal tissues and their derivatives Part 1: Application of risk management |
EN 868-2:2017 | Packaging for terminally sterilized medical devices - Part 2: Sterilization wrap - Requirements and test methods |
EN 868-3:2017 | Packaging for terminally sterilized medical devices - Part 3: Paper for use in the manufacture of paper bags (specified in EN 868-4) and in the manufacture of pouches and reels (specified in EN 868-5) - Requirements and test methods |
ISO 11140-1:2014 | Sterilization of health care products Chemical indicators Part 1: General requirements |
ISO 18472:2006 | Sterilization of health care products Biological and chemical indicators Test equipment |
ISO 11140-4:2007 | Sterilization of health care products — Chemical indicators — Part 4: Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of steam penetration |
ISO 9004:2009 | Managing for the sustained success of an organization A quality management approach |
ISO/TS 11139:2006 | Sterilization of health care products Vocabulary |
ISO 15883-4:2008 | Washer-disinfectors Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes |
ISO 10993-17:2002 | Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances |
ISO 14001:2015 | Environmental management systems — Requirements with guidance for use |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 22442-2:2015 | Medical devices utilizing animal tissues and their derivatives Part 2: Controls on sourcing, collection and handling |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
ISO 11140-5:2007 | Sterilization of health care products — Chemical indicators — Part 5: Class 2 indicators for Bowie and Dick-type air removal tests |
EN 12442-1 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK |
ISO 11138-1:2017 | Sterilization of health care products — Biological indicators — Part 1: General requirements |
ISO 22442-3:2007 | Medical devices utilizing animal tissues and their derivatives — Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
ISO 14161:2009 | Sterilization of health care products Biological indicators Guidance for the selection, use and interpretation of results |
ISO 14040:2006 | Environmental management Life cycle assessment Principles and framework |
ISO 15883-2:2006 | Washer-disinfectors — Part 2: Requirements and tests for washer-disinfectors employing thermal disinfection for surgical instruments, anaesthetic equipment, bowls, dishes, receivers, utensils, glassware, etc. |
ISO 17664:2017 | Processing of health care products Information to be provided by the medical device manufacturer for the processing of medical devices |
EN 13060:2014 | Small steam sterilizers |
EN 12442-2 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 2: CONTROLS ON SOURCING, COLLECTION AND HANDLING |
ISO 9000-3:1997 | Quality management and quality assurance standards Part 3: Guidelines for the application of ISO 9001:1994 to the development, supply, installation and maintenance of computer software |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.