AAMI/ISO TIR17665-2:2009(R2016)
Current
The latest, up-to-date edition.
STERILIZATION OF HEALTH CARE PRODUCTS - MOIST HEAT - PART 2: GUIDANCE ON THE APPLICATION OF ANSI/AAMI/ISO 17665-1
Hardcopy , PDF
English
19-06-2016
Glossary of equivalent standards
Committee representation
Background of AAMI adoption of ISO TIR17665-2:2009
AAMI inclusion to ISO TIR17665-2:2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Quality management system elements
5 Sterilizing agent characterization
6 Process and equipment characterization
7 Product definition
8 Process definition
9 Validation
10 Routine monitoring and control
11 Product release from sterilization
12 Maintaining process effectiveness
Annex A (informative) - Evaluation of a sterilization
process primarily based on the
measurement of physical parameters
Annex B (informative) - Evaluation of a sterilization
process primarily based on
biological inactivation and an
accompanying mechanical air
removal procedure
Annex C (informative) - Temperature and pressure of
saturated steam for use in
moist heat sterilization
Annex D (informative) - Special considerations for health
care settings
Annex E (informative) - Index of normative clauses/subclauses
of ISO 17665-1 and cited references
or related guidance given in ISO
17665-1 and ISO/TS 17665-2
Bibliography
Specifies general guidance on the development, validation and routine control of moist heat sterilization processes and is intended to explain the requirements set forth in ISO 17665-1.
| DevelopmentNote |
Supersedes AAMI TIR13. Together with AAMI ISO 17665-1, it supersedes AAMI ISO 11134. (07/2009)
|
| DocumentType |
Standard
|
| ISBN |
1-57020-349-0
|
| Pages |
66
|
| ProductNote |
Reconfirmed 2016
|
| PublisherName |
Association for the Advancement of Medical Instrumentation
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| ISO/TS 17665-2:2009 | Identical |
| IEC 61010-2-040:2015 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials |
| ISO 15883-1:2006 | Washer-disinfectors — Part 1: General requirements, terms and definitions and tests |
| ISO 11607-2:2006 | Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes |
| ISO 11138-3:2017 | Sterilization of health care products — Biological indicators — Part 3: Biological indicators for moist heat sterilization processes |
| ISO 15882:2008 | Sterilization of health care products — Chemical indicators — Guidance for selection, use and interpretation of results |
| EN 285:2015 | Sterilization - Steam sterilizers - Large sterilizers |
| ISO 11737-2:2009 | Sterilization of medical devices — Microbiological methods — Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process |
| ISO 11737-1:2006 | Sterilization of medical devices — Microbiological methods — Part 1: Determination of a population of microorganisms on products |
| EN 868-5:2009 | Packaging for terminally sterilized medical devices - Part 5: Sealable pouches and reels of porous materials and plastic film construction - Requirements and test methods |
| BS EN 12442-3:2000 | Animal tissues and their derivatives utilized in the manufacture of medical devices Validation of the elimination and/or inactivation of viruses and transmissible agents |
| EN 868-4:2017 | Packaging for terminally sterilized medical devices - Part 4: Paper bags - Requirements and test methods |
| BS EN 12442-2:2000 | Animal tissues and their derivatives utilized in the manufacture of medical devices Controls on sourcing, collection and handling |
| ISO 13485:2016 | Medical devices — Quality management systems — Requirements for regulatory purposes |
| ISO 14937:2009 | Sterilization of health care products — General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
| EN 867-5:2001 | Non-biological systems for use in sterilizers - Part 5: Specification for indicator systems and process challenge devices for use in performance testing for small sterilizers Type B and Type S |
| ISO/TR 14969:2004 | Medical devices — Quality management systems — Guidance on the application of ISO 13485: 2003 |
| ISO 11140-3:2007 | Sterilization of health care products — Chemical indicators — Part 3: Class 2 indicator systems for use in the Bowie and Dick-type steam penetration test |
| EN 868-2:2017 | Packaging for terminally sterilized medical devices - Part 2: Sterilization wrap - Requirements and test methods |
| EN 868-3:2017 | Packaging for terminally sterilized medical devices - Part 3: Paper for use in the manufacture of paper bags (specified in EN 868-4) and in the manufacture of pouches and reels (specified in EN 868-5) - Requirements and test methods |
| ISO 11140-1:2014 | Sterilization of health care products — Chemical indicators — Part 1: General requirements |
| ISO 3746:2010 | Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Survey method using an enveloping measurement surface over a reflecting plane |
| ISO 11140-4:2007 | Sterilization of health care products — Chemical indicators — Part 4: Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of steam penetration |
| ISO/TS 11139:2006 | Sterilization of health care products — Vocabulary |
| ISO 15883-4:2008 | Washer-disinfectors — Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes |
| ISO 10993-17:2002 | Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances |
| ISO 14001:2015 | Environmental management systems — Requirements with guidance for use |
| ISO 10993-1:2009 | Biological evaluation of medical devices — Part 1: Evaluation and testing within a risk management process |
| ISO 14644-1:2015 | Cleanrooms and associated controlled environments — Part 1: Classification of air cleanliness by particle concentration |
| ISO 11140-5:2007 | Sterilization of health care products — Chemical indicators — Part 5: Class 2 indicators for Bowie and Dick-type air removal tests |
| BS EN 12442-1:2000 | Animal tissues and their derivatives utilized in the manufacture of medical devices Analysis and management of risk |
| ISO 11138-1:2017 | Sterilization of health care products — Biological indicators — Part 1: General requirements |
| ANSI/AAMI ST79:2017 | COMPREHENSIVE GUIDE TO STEAM STERILIZATION AND STERILITY ASSURANCE IN HEALTH CARE FACILITIES |
| ISO 14971:2007 | Medical devices — Application of risk management to medical devices |
| ISO 11607-1:2006 | Packaging for terminally sterilized medical devices — Part 1: Requirements for materials, sterile barrier systems and packaging systems |
| ISO 14161:2009 | Sterilization of health care products — Biological indicators — Guidance for the selection, use and interpretation of results |
| ISO 14040:2006 | Environmental management — Life cycle assessment — Principles and framework |
| ISO 15883-2:2006 | Washer-disinfectors — Part 2: Requirements and tests for washer-disinfectors employing thermal disinfection for surgical instruments, anaesthetic equipment, bowls, dishes, receivers, utensils, glassware, etc. |
| ISO 17664:2017 | Processing of health care products — Information to be provided by the medical device manufacturer for the processing of medical devices |
| EN 13060:2014 | Small steam sterilizers |
| ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |