ANSI/NEMA FI 3:2004
Current
The latest, up-to-date edition.
Calendered Aramid Papers Used for Electrical Insulation
Hardcopy , PDF
English
30-09-2004
Foreword
Section 1 General
1.1 Scope
1.2 Definition of Aramid Paper
1.3 References
1.3.1 Mandatory Standard
Section 2 Tolerances
2.1 Tolerances on Thickness of Aramid Papers
2.2 Tolerance on Width of Aramid Paper Tapes
2.3 Tolerances for Dimensions of Narrow Aramid Paper Rolls
2.4 Tolerances for Dimensions of Wide Aramid Paper Rolls
2.5 Tolerances for Dimensions of Aramid Paper Sheets
Section 3 Classification of Aramid Papers
3.1 Definitions of Defects
3.1.1 Defects Causing Reduced insulation Strength
3.1.2 Holes
3.1.3 Fractures
3.1.4 Solid Tactile Defects
3.1.5 Hollow Tactile Defects (Blisters)
3.1.6 Stains and Discolorations
3.1.7 Splices
3.2 Sampling for Testing
3.2.1 Samples from Rolls
3.3 Method of Calculation
Section 4 Methods of Measurement
4.1 Methods of Measuring Thickness
4.1.1 Sheets
4.1.2 Tapes
4.2 Methods of Measuring Electric Strength
4.2.1 Sheets and Tapes
4.3 Method do Determining Moisture Content
4.3.1 Purpose
4.3.2 Apparatus
4.3.3 Test Specimen
4.3.4 Procedure
4.3.5 Report
4.4 Method of Testing Tensile Properties
4.4.1 Conditioning
4.4.2 Sampling
4.4.3 Reporting
Section 5 TYPES OF ARAMID PAPER
Section 6 SPECIFICATION BY TYPE AND THICKNESS
Section 7 ELECTRICAL PROPERTIES-TYPE TESTS
Applies to qualification and testing of calendered aramid papers in thicknesses up to 30 mils (0.76 mm) for use as electrical insulation.
DocumentType |
Standard
|
Pages |
17
|
PublisherName |
National Electrical Manufacturers Association
|
Status |
Current
|
MIL-HDBK-454 Revision B:2007 | GENERAL GUIDELINES FOR ELECTRONIC EQUIPMENT |
MIL-DTL-917 Revision F:2014 | ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR |
MIL-DTL-12883-53 Revision B:2003 | SOCKETS AND ACCESSORIES FOR PLUG-IN ELECTRONIC COMPONENTS, MOUNTING TRACK, FOR RELAY SOCKETS AND ELECTROMAGNETIC RELAYS |
MIL STD 11991 : A | GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES |
IEC 60819-3-3:2011 | Non-cellulosic papers for electrical purposes - Part 3: Specifications for individual materials - Sheet 3: Unfilled aramid (aromatic polyamide) papers |
ASTM D 1004 : 2013 : REDLINE | Standard Test Method for Tear Resistance (Graves Tear) of Plastic Film and Sheeting |
ASTM D 2176 : 2016 | Standard Test Method for Folding Endurance of Paper and Plastics Film by the M.I.T. Tester |
ASTM D 1830 : 1999 | Standard Test Method for Thermal Endurance of Flexible Sheet Materials Used for Electrical Insulation by the Curved Electrode Method |
ASTM D 3394 : 2016 : REDLINE | Standard Test Methods for Sampling and Testing Electrical Insulating Board |
ASTM D 257 : 2014 : REDLINE | Standard Test Methods for DC Resistance or Conductance of Insulating Materials |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
ASTM D 374 : 1999 | Standard Test Methods for Thickness of Solid Electrical Insulation |
ASTM D 2275 : 2014 : REDLINE | Standard Test Method for Voltage Endurance of Solid Electrical Insulating Materials Subjected to Partial Discharges (Corona) on the Surface |