• AS 1026-1992

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electric cables - Impregnated paper insulated - Working voltages up to and including 33 kV

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2017

    Language(s): 

    Published date:  01-01-1992

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 1026-1992 ELECTRIC CABLES - IMPREGNATED PAPER INSULATED - WORKING VOLTAGES UP TO AND INCLUDING 33 kV
    4 - PREFACE
    5 - CONTENTS
    7 - 1 SCOPE
    7 - 2 REFERENCED DOCUMENTS
    7 - 3 DEFINITIONS
    7 - 3.1 Core (of a cable)
    7 - 3.2 Conductor screen
    7 - 3.3 Screened cable
    8 - 3.4 Multicore cable
    8 - 3.5 Belted cable
    8 - 3.6 Separately leaded (SL) cable
    8 - 3.7 Direction of lay
    8 - 3.8 Maximum permissible continuous conductor temperature
    8 - 3.9 Voltage designation
    8 - 3.10 Nominal values
    8 - 3.11 Approximate value
    8 - 3.12 Breaking joint
    8 - 3.13 Registration
    8 - 3.14 Non-hygroscopic
    8 - 4 OPERATING VOLTAGES
    8 - 5 MAXIMUM CONDUCTOR TEMPERATURES
    8 - 6 CONDUCTORS
    10 - 7 CONDUCTOR SCREEN
    10 - 8 INSULATION
    10 - 8.1 General
    10 - 8.2 Material
    10 - 8.3 Method of application
    10 - 8.4 Thickness of paper
    10 - 8.5 Thickness of insulation
    10 - 9 CORE IDENTIFICATION
    10 - 10 INSULATION SCREEN
    10 - 10.1 General
    10 - 10.2 Screen
    10 - 10.3 Additional screening
    10 - 11 LAYING UP
    10 - 11.1 Belted cables
    11 - 11.2 Screened cables
    11 - 11.3 Screened SL cables
    11 - 11.4 Direction of lay
    11 - 12 IMPREGNATION
    11 - 12.1 General
    11 - 12.2 Compound test
    11 - 12.3 Breaking load and elongation at break of impregnated paper
    11 - 13 IDENTIFICATION OF MANUFACTURER
    11 - 14 LEAD ALLOY SHEATH
    11 - 14.1 General
    11 - 14.2 Composition
    11 - 14.3 Thickness
    11 - 14.4 External coating
    11 - 15 BEDDING
    11 - 15.1 General
    11 - 15.2 Lapped bedding
    11 - 15.3 Extruded bedding
    12 - 16 ARMOUR
    12 - 16.1 General
    12 - 16.2 Single-wire armour
    12 - 16.3 Double-wire armour
    12 - 17 NON-METALLIC SHEATH OR SERVING
    12 - 17.1 Non-metallic sheath
    12 - 17.2 Serving for armoured cables
    12 - 18 COMPOUNDS FOR LAPPED BEDDING AND SERVING
    12 - 19 CABLE MARKINGS
    12 - 19.1 End markings
    12 - 19.2 Identification of cables without non-metallic sheath
    13 - 19.3 Embossing or indenting of non-metallic sheath
    13 - 19.4 Metre marking on non-metallic sheath
    13 - 20 SEALING AND PREPARATION FOR DELIVERY
    13 - 20.1 General
    13 - 21 TESTS
    13 - 21.1 General
    13 - 21.2 Test categories
    13 - 21.3 Measurement of conductor resistance (RT)
    13 - 21.4 Voltage tests (RT)
    14 - 21.5 Dielectric dissipation factor/voltage test (RT)
    15 - 21.6 Electrical tests on extruded non-metallic sheaths (RT)
    15 - 21.7 Measurement of insulation thickness (ST)
    16 - 21.8 Bending test (ST)
    16 - 21.9 Drainage test (ST)
    17 - 21.10 Residual compound congealing point test
    17 - 21.11 Breaking load and elongation at break of impregnated paper (ST)
    28 - APPENDIX A - RECOMMENDATIONS FOR THE SELECTION AND OPERATION OF PAPER-INSULATED CABLES
    28 - A1 VOLTAGE RATINGS
    28 - A1.1 Categories
    28 - A1.2 Category 1
    28 - A1.3 Category 2
    28 - A2 PROTECTIVE COVERINGS
    28 - A2.1 Non-metallic sheath
    28 - A2.2 Flame-retardant coverings
    28 - A3 PROTECTION AGAINST TERMITE OR ANT ATTACK
    28 - A4 CURRENT RATINGS
    28 - A5 SHORT CIRCUIT RATINGS
    30 - APPENDIX B - RECOMMENDATIONS FOR THE INSTALLATION OF PAPER-INSULATED CABLES
    30 - B1 MINIMUM TEMPERATURE DURING INSTALLATION
    30 - B2 MINIMUM INSTALLATION RADIUS
    30 - B3 TESTS AFTER INSTALLATION
    32 - APPENDIX C - SPECIAL TEST SAMPLE SELECTION AND RETEST PROCEDURE
    32 - C1 SELECTION OF SAMPLES
    32 - C2 RE-TEST PROCEDURE
    33 - APPENDIX D - TYPE TESTS FOR 19/33 kV CABLES
    33 - D1 PRELIMINARY PROCEDURE
    33 - D2 LOADING CYCLE TEST
    33 - D2.1 Test installation
    33 - D2.2 PROCEDURE
    33 - D3 IMPULSE VOLTAGE TEST
    33 - D3.1 Test installation
    33 - D3.2 Principle
    33 - D3.3 Detailed test method
    35 - APPENDIX E - METHOD OF TEST FOR WATER-SOLUBLE IMPURITIES IN INSULATING PAPER
    35 - APPENDIX F - INFORMATION REQUIRED WITH ENQUIRY AND ORDER
    36 - APPENDIX G - DETERMINATION OF THICKNESS OF LEAD ALLOY SHEATH AND EXTRUDED BEDDING
    36 - G1 GENERAL
    36 - G2 METHOD OF MEASURING THICKNESS
    36 - G2.1 Lead alloy sheath
    36 - G2.2 Extruded bedding

    Abstract - (Show below) - (Hide below)

    Specifies the requirements for non-draining mass-impregnated paper insulated and lead alloy sheathed cables for working voltages up to and including 19/33 kV.

    Scope - (Show below) - (Hide below)

    This Standard specifies requirements for non-draining mass-impregnated paper insulated and lead alloy sheathed cables for working voltages up to and including 19/33 kV. Provision is made for extruded or lapped non-metallic protective coverings over the lead alloy sheath, with or without galvanized steel wire armour. Some typical constructions are shown in Figure 1.NOTE: Recommendations for selection and operation are given in Appendix A and those for installation are given in Appendix B.The following cables are included in this Standard:(a) 0.6/1 kV single-core, two-core, three-core and four-core.(b) 1.9/3.3 kV and 3.8/6.6 kV single-core and three-core belted construction.(c) 6.35/11 and 11/11 kV single-core and three-core belted or screened construction.(d) 12.7/22 kV and 19/33 kV single-core and three-core screened or three-core separately leaded (SL).

    General Product Information - (Show below) - (Hide below)

    Committee EL-003
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    Under Revision see DR 02316 First published as AS C92-1941.Withdrawn 1970.Revised and redesignated AS 1026-1973.Second edition 1992. First published as AS C92-1941. Withdrawn 1970. Revised and redesignated AS 1026-1973. Second edition 1992.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 3983-1991 Metal drums for insulated electric cables and bare conductors (Reconfirmed 2016)
    AS 1125-1993 Conductors in insulated electric cables and flexible cords
    AS 2857-1986 Timber drums for insulated electric cables and bare conductors
    AS 3863-1991 Galvanized mild steel wire for armouring cables
    AS 2886-1986 Voltage measurement - Sphere-gap method (one sphere earthed)
    AS 2893-1986 Electric cables - Lead and lead alloy sheaths - Composition
    AS 3147-1992 Approval and test specification - Electric cables - Thermoplastic insulated - For working voltages up to and including 0.6/1 kV
    AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
    AS 3008.1-1989 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV
    AS 1429-1985 Polymeric insulated cables for electricity supply at working voltages 1.9/3.3 kV up to and including 19/33 kV

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 4805.2:2003 Accessories for electric cables - Test requirements - Impregnated paper-insulated metal-sheathed cables for rated voltages from 1.9/3.3 (3.6) kV up to 19/33 (36) kV (excluding gas-pressure and oil-filled cables)
    AS 1972-1991 Electric cables - Underground coal mines - Other than reeling and trailing cables
    AS/NZS 4026:2001 Electric cables - For underground residential distribution systems
    AS 4026-1992 Electric cables - For underground residential distribution systems
    AS/NZS 3808:1998 Insulating and sheathing materials for electric cables
    AS/NZS 1972:2002 Electric cables - Underground coal mines - Other than reeling and trailing
    AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
    AS/NZS 3808:2000 Insulating and sheathing materials for electric cables
    AS/NZS 1972:1996 Electric cables - Underground coal mines - Other than reeling and trailing
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective