AS 1289.5.8.9-1998
Current
The latest, up-to-date edition.
Methods of testing soils for engineering purposes Soil compaction and density tests - Nuclear surface moisture-density gauges - Water content of a standard moisture block using comparison against primary blocks (Reconfirmed 2013) (Reconfirmed 2014)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
05-06-1998
This Standard has been reconfirmed. To view or download the Reconfirmation Notice please click here.
This Standard sets out the method for the determination of the assigned water content, by comparison against a set of primary moisture blocks of a standard moisture block, to be used for the calibration of the moisture mode of nuclear surface moisture-density gauges in accordance with AS 1289.5.8.4. The block shall consist of an array of alternate vertical aluminium or magnesium and polyethylene plates. The assignment of water content is made using comparison against a set of primary moisture blocks. Guidance on the number of blocks required for a set of standard moisture blocks is given in AS 1289.5.8.4.
Committee |
CE/9
|
DocumentType |
Standard
|
ISBN |
0 7337 2032 3
|
Pages |
6
|
ProductNote |
Reconfirmed 08-07-2013
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard sets out the method for the determination of the assigned water content, by comparison against a set of primary moisture blocks of a standard moisture block, to be used for the calibration of the moisture mode of nuclear surface moisture-density gauges in accordance with AS 1289.5.8.4. The block shall consist of an array of alternate vertical aluminium or magnesium and polyethylene plates. The assignment of water content is made using comparison against a set of primary moisture blocks. Guidance on the number of blocks required for a set of standard moisture blocks is given in AS 1289.5.8.4.A separate assigned water content for a particular standard moisture block is required for each make of gauge and, in some cases, for different models of the same make. The determination of the assigned water content for a particular standard moisture block shall be completed within one year of commencement, and the value of the assigned water content for a particular gauge make, and model if necessary, cannot be calculated until allof the predicted water content values have been obtained.For any gauge, the determination of a predicted water content value for a standard moisture block is usually made during the calibration, but not as part of the calibration, of the gauge.
First published as AS 1289.5.8.9-1998.
AS 1289.5.8.7-1998 | Methods of testing soils for engineering purposes Soil compaction and density tests - Nuclear surface moisture-density gauges - Water content of a standard moisture block using hydrogen content of components |
AS 1289.5.8.4-1998 | Methods of testing soils for engineering purposes Soil compaction and density tests - Nuclear surface moisture-density gauges - Calibration using standard blocks |
AS 1289.5.8.8-1998 | Methods of testing soils for engineering purposes Soil compaction and density tests - Nuclear surface moisture-density gauges - Water content of a standard moisture block using proportion of water (Reconfirmed 2013) |
AS 1289.5.8.4-1998 | Methods of testing soils for engineering purposes Soil compaction and density tests - Nuclear surface moisture-density gauges - Calibration using standard blocks |
HB 160-2006 | Soils testing |
AS 1289.5.8.7-1998 | Methods of testing soils for engineering purposes Soil compaction and density tests - Nuclear surface moisture-density gauges - Water content of a standard moisture block using hydrogen content of components |
AS/NZS 3500.5:2012 | Plumbing and drainage Housing installations |
AS/NZS 3725:2007 | Design for installation of buried concrete pipes |
AS 1289.5.8.4-2009 | Methods of testing soils for engineering purposes Soil compaction and density tests - Nuclear surface moisture-density gauges - Calibration using standard blocks |
AS 3727.1:2016 | Pavements Residential |
AS 4799-2000 | Installation of underground utility services and pipelines within railway boundaries |
AS 1289.5.8.8-1998 | Methods of testing soils for engineering purposes Soil compaction and density tests - Nuclear surface moisture-density gauges - Water content of a standard moisture block using proportion of water (Reconfirmed 2013) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.