1 - AS 1324.2-2003 AIR FILTERS FOR USE IN GENERAL VENTILATION AND AIRCONDITIONING - METHODS OF TEST
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 REFERENCED DOCUMENTS
7 - 1.3 GENERAL INFORMATION
8 - 1.4 DEFINITIONS
9 - SECTION 2 INITIAL RESISTANCE
9 - 2.1 SCOPE
9 - 2.2 APPLICATION
9 - 2.3 PRINCIPLE
9 - 2.4 APPARATUS AND MATERIALS
9 - 2.5 PROCEDURE
9 - 2.6 TEST REPORT
10 - SECTION 3 MASS STABILIZATION
10 - 3.1 SCOPE
10 - 3.2 APPLICATION
10 - 3.3 PRINCIPLE
10 - 3.4 APPARATUS AND MATERIALS
10 - 3.5 PROCEDURE
10 - 3.6 TEST REPORT
11 - SECTION 4 TEST DUST NO. 1-EFFICIENCY TEST
11 - 4.1 SCOPE
11 - 4.2 APPLICATON
11 - 4.3 PRINCIPLE
11 - 4.4 COMPOSITION
11 - 4.5 NOTATION
12 - 4.6 APPARATUS
12 - 4.6.1 General
12 - 4.6.2 Air sample size
12 - 4.7 PROCEDURE
12 - 4.7.1 Routine test preparation
13 - 4.7.2 Zero efficiency test
13 - 4.7.3 Test procedure
14 - 4.8 CALCULATIONS
16 - 4.9 TEST REPORT
17 - SECTION 5 TEST DUST NO. 4-GRAVIMETRIC TESTS
17 - 5.1 SCOPE
17 - 5.2 PRINCIPLE
17 - 5.3 APPARATUS, MATERIALS AND REAGENTS
18 - 5.4 PROCEDURE
18 - 5.5 CALCULATIONS
18 - 5.5.1 Arrestance
19 - 5.5.2 Average arrestance
19 - 5.5.3 Dust holding capacity
19 - 5.6 TEST REPORT
20 - SECTION 6 EFFECTIVENESS OF RENEWING MECHANISM
20 - 6.1 SCOPE
20 - 6.2 PRINCIPLE
20 - 6.3 APPARATUS AND MATERIALS
20 - 6.4 TEST SAMPLE FILTER
20 - 6.5 PROCEDURE
20 - 6.6 TEST REPORT
21 - SECTION 7 TEST DUSTS NOS 2 AND 3-SPECIAL TESTS
21 - 7.1 SCOPE
21 - 7.2 APPLICATION
21 - 7.3 GRAVIMETRIC TESTS
21 - 7.4 EFFECTIVENESS OF RENEWING MECHANISM TEST
21 - 7.5 TEST DUST COMPOSITION
21 - 7.6 TEST REPORTS
22 - SECTION 8 TEST REPORTS
22 - 8.1 REPORTS
22 - 8.2 GRAPHS
22 - 8.3 PRELIMINARY INFORMATION
22 - 8.4 INFORMATION
22 - 8.4.1 Initial resistance test
23 - 8.4.2 Mass stabilization test
23 - 8.4.3 Efficiency/arrestance test
24 - 8.4.4 Gravimetric tests
24 - 8.4.5 Effectiveness of renewing mechanism test
24 - 8.5 DEVIATIONS FROM STANDARD TEST PROCEDURE
26 - APPENDIX A - GENERAL EQUIPMENT AND TEST REQUIREMENTS
26 - A1 CONDITION OF AIR
26 - A2 TEST RIG
26 - A2.1 Ductwork
26 - A2.2 Inlet section
26 - A2.3 Filter housing
26 - A2.4 Outlet section
27 - A2.5 Fan
27 - A3 PRESSURE GAUGE
27 - A4 COMPRESSED AIR SUPPLY
27 - A5 ORIFICE PLATE MANOMETER
27 - A6 FILTER RESISTANCE MANOMETER
27 - A7 WANDER LEAD
27 - A8 ACCESSORY ITEMS
27 - A9 CONNECTIONS
27 - A10 BALANCES
27 - A11 GRAVIMETRIC DUST FEEDER
28 - A12 ITEMS APPLICABLE TO TEST DUST NO.1, EFFICIENCY TEST
28 - A12.1 Atomizer
28 - A12.2 Sample tubes
28 - A12.3 Gas meters
28 - A12.4 Photometer
29 - A12.5 Sampling test papers
29 - A13 MATERIALS
29 - A13.1 Test Dust No. 1
29 - A13.2 Test Dust No. 4
30 - A13.3 Test Dusts Nos. 2 and 3
30 - A13.4 Particle size
30 - A14 COMPRESSRED AIR FLOWMETER
30 - A14.1 Type and capacity
30 - A14.2 Regulator valve
30 - A15 TEST FILTER SAMPLE PREPARATION

Provides a method for laboaratory or bench testing of air filters used in general ventilation and airconditioning systems.

Committee
ME-080
DocumentType
Standard
ISBN
0 7337 5157 1
Pages
33
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard provides test methods for laboratory or bench testing of air filters used in general ventilation and airconditioning systems. It also includes general information on test dusts, test rig and apparatus. Test methods for filter applications are given in AS 1324.1. NOTES: 1 Requirements of performance and construction of air filters for use in general ventilation and airconditioning are specified in AS 1324.1. 2 Methods for on-site testing of High Efficiency Particulate Air filters (HEPA filters) are specified in AS 1807 series. Performance, construction and methods of test for HEPA filters are specified in AS 4260.

Originated in part as AS 1132.1-1973, AS 1132.2-1973.
AS 1132.3-1973, AS 1132.4-1973, AS 1132.5-1973, AS 1132.6-1973, AS 1132.7-1973, AS 1132.8-1973, and part of AS 1323-1973.
Previous edition AS 1324.2-1996.
Second edition 2003.

AS 1807.13-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of relative humidity in cleanrooms
AS 4260-1997 High efficiency particulate air (HEPA) filters - Classification, construction and performance (Reconfirmed 2018)
AS 1807.9-1989 Cleanrooms, workstations and safety cabinets - Methods of test Particle counting in cleanrooms by microscopic sizing and counting
AS 2360.1.1-1993 Measurement of fluid flow in closed conduits Pressure differential methods - Measurement using orifice plates, nozzles or Venturi tubes - Conduits with diameters from 50 mm to 1200 mm
AS 1807.10-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air pressure of cleanrooms and pharmaceutical isolators
AS 1807.22-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air barrier containment of laminar flow safety cabinets
AS 1807.20-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of sound level at installed workstations, safety cabinets and pharmaceutical isolators
AS 1289.3.6.3-2003 Methods of testing soils for engineering purposes Soil classification tests - Determination of the particle size distribution of a soil - Standard method of fine analysis using a hydrometer
AS 1807.12-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of temperature in work zones
AS 1807.11-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of airflow parallelism in laminar flow cleanrooms
AS 1807.3-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air velocity in laminar flow cleanrooms
AS 1807.4-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of performance of laminar flow cleanrooms under loaded filter conditions
AS 1807.0-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test List of methods and apparatus
AS 1807.16-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of sound level in cleanrooms
AS 1807.1-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air velocity and uniformity of air velocity in clean workstations, laminar flow safety cabinets and pharmaceutical isolators
AS 1349-1986 Bourdon tube pressure and vacuum gauges (Reconfirmed 2018)
AS 1807.24-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of recovery times of cleanrooms
AS 1807.7-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of integrity of HEPA filter installations not terminally mounted
AS 1807.21-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of inward air velocity of Class I biological safety cabinets
AS 1807.19-1989 Cleanrooms, workstations and safety cabinets - Methods of test Sizing and counting of particulate contaminants in and on cleanroom garments
AS 1289.3.6.3-1994 Methods of testing soils for engineering purposes Soil classification tests - Determination of the particle size distribution of a soil - Standard method of fine analysis using a hydrometer
AS 1807.2-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of performance of clean workstations, laminar flow safety cabinets and pharmaceutical isolators under loaded filter conditions
AS 1807.23-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of intensity of radiation from germicidal ultraviolet lamps
AS 1807.8-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Particle counting in work zone by automatic particle counter
AS 1807.15-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of illuminance
AS 1807.17-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of vibration in cleanrooms
AS 1324.1-2001 Air filters for use in general ventilation and airconditioning Application, performance and construction
AS 1807.25-1990 Cleanrooms, workstations and safety cabinets - Methods of test Determination of gas tightness of outer shell of biological safety cabinets
AS 1807.18-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of vibration in workstations, safety cabinets and pharmaceutical isolators
AS 1807.6-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of integrity of terminally mounted HEPA filter installations
AS 1807.5-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of work zone integrity

AS/NZS 4361.1:2017 Guide to hazardous paint management Lead and other hazardous metallic pigments in industrial applications
AS/NZS 2243.3:2002 Safety in laboratories Microbiological aspects and containment facilities
AS 2252.1-2002 Biological safety cabinets - Biological safety cabinets (Class I) for personnel and environment protection
AS 4125.1-2009 Sound laboratory practice in food and water microbiology laboratories - Premises, safety, sample management, regulatory compliance and record management
AS 2567-2002 Laminar flow cytotoxic drug safety cabinets
AS 2514-1999 Drying cabinets for medical equipment
AS/NZS 3666.1:2002 Air-handling and water systems of buildings - Microbial control Design, installation and commissioning
AS/NZS 4361.2:2017 Guide to hazardous paint management Lead paint in residential, public and commercial buildings
AS/NZS 2243.3:2010 Safety in laboratories Microbiological safety and containment
AS 2252.5:2017 Controlled environments Cytotoxic drug safety cabinets (CDSC) - Design, construction, installation, testing and use
AS 1324.1-2001 Air filters for use in general ventilation and airconditioning Application, performance and construction
AS 1668.2-2012 The use of ventilation and airconditioning in buildings Mechanical ventilation in buildings

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.