• Shopping Cart
    There are no items in your cart

AS 1530.7-2007

Current

Current

The latest, up-to-date edition.

Methods for fire tests on building materials, components and structures Smoke control assemblies - Ambient and medium temperature leakage test procedure (Reconfirmed 2018)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

02-07-2007

€65.33
Excluding VAT

1 - AS 1530.7-2007 METHODS FOR FIRE TESTS ON BUILDING MATERIALS, COMPONENTS AND STRUCTURES - SMOKE CONTROL ASSEMBLIES-...
4 - PREFACE
6 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 OBJECTIVES
7 - 1.3 PRINCIPLE
7 - 1.4 APPLICATION
7 - 1.5 REFERENCED DOCUMENTS
8 - 1.6 DEFINITIONS
8 - 1.6.1 Ambient temperature
8 - 1.6.2 Associated construction
8 - 1.6.3 Damper assembly
8 - 1.6.4 Door and shutter assembly
8 - 1.6.5 Forces
8 - 1.6.6 Leakage rate
8 - 1.6.7 Medium temperature
8 - (1.6.8 Pressure difference
8 - 1.6.9 Service
8 - 1.6.10 Shall
8 - 1.6.11 Should
9 - 1.6.12 Smoke door
9 - 1.6.13 Standard Reference Conditions
9 - 1.6.14 Supporting construction
9 - 1.6.15 Test specimen
9 - 1.7 SYMBOLS
10 - SECTION 2 TEST METHOD
10 - 2.1 SCOPE OF SECTION
10 - 2.2 TEST APPARATUS
10 - 2.3 INSTRUMENTATION
10 - 2.3.1 Differential pressure
10 - 2.3.2 Air temperature
11 - 2.3.3 Airflow
11 - 2.3.4 Opening and closing forces
12 - 2.4 TEST SPECIMEN
12 - 2.4.1 Number
12 - 2.4.2 Size
12 - 2.4.3 Construction
12 - 2.4.4 Conditioning
12 - 2.4.5 Pretest analysis
14 - 2.5 TEST PROCEDURE
14 - 2.5.1 Setting-up procedure
14 - 2.5.2 Air leakage test
16 - 2.6 OBSERVATIONS
17 - SECTION 3 REPORTING OF RESULTS
17 - 3.1 EXPRESSION OF RESULTS
17 - 3.1.1 General
17 - 3.1.2 Measured values
17 - 3.1.3 Standard Reference Conditions
18 - 3.2 TEST REPORT
19 - APPENDIX A - TEST PRINCIPLE
20 - APPENDIX B - TEST APPARATUS
20 - B1 TEST APPARATUS
20 - B2 TEST CHAMBER
22 - APPENDIX C - PROCEDURES FOR CALCULATING LEAKAGE RATES
22 - C1 GENERAL
22 - C2 PROCEDURE
23 - APPENDIX D - MEASUREMENT OF DEFORMATION

Sets out test procedures for a method of test for determining the smoke leakage through doors and shutters. Follows the basic principles and provisions contained in ISO5925-1.

Committee
FP-018
DocumentType
Standard
ISBN
0 7337 8272 8
Pages
18
ProductNote
Reconfirmed 16/11/2018.
This standard has been reconfirmed in Australia in 2018 and remains current in New Zealand. Reconfirmation Notice 16/11/2018
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard sets out a method to measure the leakage of ambient and medium temperature smoke from one side of an assembly to the other under specified test conditions. The test can be applied to assemblies of different types primarily to control the passage of smoke at ambient and medium temperatures.

Originated as AS/NZS 1530.7:1998.
Revised and redesignated as AS 1530.7-2007.

AS 4072.1-2005 Components for the protection of openings in fire-resistant separating elements Service penetrations and control joints (Reconfirmed 2016)
AS 1530.4-2005 Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction

AS 1530.4-2005 Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction
AS 1905.2-2005 Components for the protection of openings in fire-resistant walls Fire-resistant roller shutters (Reconfirmed 2016)
AS 6905-2007 Smoke doors (Reconfirmed 2016)
AS 1905.1-2005 Components for the protection of openings in fire-resistant walls Fire-resistant doorsets
AS 4072.1-2005 Components for the protection of openings in fire-resistant separating elements Service penetrations and control joints (Reconfirmed 2016)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.