AS 1603.3-1996
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Automatic fire detection and alarm systems - Heat alarms
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
24-06-2021
English
01-01-1996
Specifies the requirements for the design, construction and performance of electrically energized heat alarms, containing both detection and alarm facilities, that are intended for use in conjunction with smoke alarms.
Committee |
FP-002
|
DocumentType |
Standard
|
ISBN |
0 7337 0845 5
|
Pages |
11
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard specifies requirements for the design and performance of electrically energized heat alarms containing both detection and alarm facilities.This Standard requires the inclusion of facilities within the heat alarm for interconnection with other similar units and smoke alarms. However, such an interface is not intended for connection to a monitoring service.
First published as AS 1603.3-1996.
AS 2362.20-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Overload test |
AS 2362.13-2002 | Fire detection, warning, control and intercom systems Methods of test - Corrosion test (Reconfirmed 2016) |
AS 3100-1990 | Approval and test specification - General requirements for electrical equipment |
AS 2362.5-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Insulation resistance test |
AS 2362.13-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Corrosion test |
AS 2362.22-2002 | Fire detection, warning, control and intercom systems Methods of test - Sound pressure level test (Reconfirmed 2016) |
AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
AS 2362.1-2002 | Fire detection, warning, control and intercom systems Methods of test - Heat sensitivity testing of types A, B, C and D heat detectors (Reconfirmed 2016) |
AS 2362.15-2002 | Fire detection, warning, control and intercom systems Methods of test - Vibration test (Reconfirmed 2016) |
AS 2362.10-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Low temperature test |
AS 2362.1-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Heat sensitivity testing of types A, B, C and D heat detectors |
AS 2706-2003 | Numerical values - Rounding and interpretation of limiting values (Reconfirmed 2018) |
AS 2362.9-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - High frequency disturbance test |
AS 3000-1986 | Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules) |
AS 2362.12-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Dry heat test |
AS 2362.7-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Electromagnetic interference test |
AS 2362.6-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Static discharge test |
AS 2706-1984 | Numerical values - Rounding and interpretation of limiting values |
AS 2362.4-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Voltage stability test |
AS 2362.15-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Vibration test |
AS 2362.12-2002 | Fire detection, warning, control and intercom systems Methods of test - Dry heat test (Reconfirmed 2016) |
AS 1670-1986 | Automatic fire detection and alarm systems - System design, installation, and commissioning |
AS 2362.20-2002 | Fire detection, warning, control and intercom systems - Methods of test Overload test (Reconfirmed 2016) |
AS 2362.21-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Endurance test |
AS 2362.10-2002 | Fire detection, warning, control and intercom systems - Methods of test Low temperature test (Reconfirmed 2016) |
AS 2362.8-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Impulse voltage withstand test |
AS 2484.2-1991 | Fire - Glossary of terms Fire protection and firefighting equipment |
AS 2362.11-2002 | Fire detection, warning, control and intercom systems Methods of test - Damp heat test |
AS 2362.21-2002 | Fire detection, warning, control and intercom systems Methods of test - Endurance test (Reconfirmed 2016) |
AS 2484.1-1990 | Fire - Glossary of terms Fire tests (Reconfirmed 2016) |
AS 2362.11-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Damp heat test |
AS 2546.1-1982 | Printed boards General requirements and test methods |
AS 2362.22-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Sound pressure level test |
AS 1851.15-1997 | Maintenance of fire protection equipment - Local fire alarm systems |
AS 3007.3-2004 | Electrical installations - Surface mines and associated processing plant General requirements for equipment and ancillaries |
AS 1670.2-1997 | Fire detection, warning, control and intercom systems - System design, installation and commissioning - Local fire |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
AS 1670.1-2004 | Fire detection, warning, control and intercom systems - System design, installation and commissioning Fire |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.