• AS 1670.1-2004

    AvailableSuperseded An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by SAI Global as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.

    Fire detection, warning, control and intercom systems - System design, installation and commissioning Fire

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s): 

    Published date:  29-04-2004

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 1670.1-2004 FIRE DETECTION, WARNING, CONTROL AND INTERCOM SYSTEMS-SYSTEM DESIGN, INSTALLATIO AND COMMISSIONING - PART 1: F
    4 - PREFACE
    6 - CONTENTS
    8 - SECTION 1 SCOPE AND GENERAL
    8 - 1.1 SCOPE
    8 - 1.2 APPLICATION
    8 - 1.3 REFERENCED DOCUMENTS
    10 - 1.4 DEFINITIONS
    10 - 1.4.1 Adjacent
    10 - 1.4.2 Alarm acknowledgment facility
    10 - 1.4.3 Alarm signalling equipment
    10 - 1.4.4 Alarm verification facility
    10 - 1.4.5 Approval (approved)
    10 - 1.4.6 Contiguous
    10 - 1.4.7 Corridor
    10 - 1.4.8 Cupboard
    10 - 1.4.9 Designated building entry point
    10 - 1.4.10 Designated site entry point
    10 - 1.4.11 Distributed system
    10 - 1.4.12 Extra-low voltage
    11 - 1.4.13 Fire dispatch centre
    11 - 1.4.14 Level surface
    11 - 1.4.15 Low voltage
    11 - 1.4.16 Monitoring service provider
    11 - 1.4.17 Multi-sensor detector
    11 - 1.4.18 Occupied area
    11 - 1.4.19 Power supply
    11 - 1.4.20 Protected area
    11 - 1.4.21 Protected building
    11 - 1.4.22 Separate cable path
    11 - 1.4.23 Site
    11 - 1.4.24 Sloping surface
    11 - 1.4.25 Sole occupancy unit
    11 - 1.4.26 Supervised
    12 - 1.5 INTERPRETATION OF SPECIFIED LIMITING VALUES
    13 - SECTION 2 SYSTEM CONFIGURATION
    13 - 2.1 COMPONENTS
    14 - 2.2 SEPARATION OF SYSTEMS
    14 - 2.3 DESIGNATED ENTRY POINT
    14 - 2.3.1 Designated building entry point
    15 - 2.3.2 Designated site entry point
    15 - 2.4 ALARM ZONE LIMITATIONS
    17 - 2.5 ADDRESSABLE CIRCUITS
    18 - 2.6 DISTRIBUTED SYSTEMS
    18 - 2.6.1 Subindicator panels
    18 - 2.6.2 Distributed parts of CIE
    19 - 2.6.3 Signal path fault indication
    20 - 2.6.4 Signal path protection
    21 - SECTION 3 INSTALLATION REQUIREMENTS
    21 - 3.1 GENERAL
    21 - 3.2 ALARM ACKNOWLEDGMENT FACILITY
    21 - 3.3 DEPENDENCY ON MORE THAN ONE ALARM SIGNAL (ALARM VERIFICATION FACILITY)
    22 - 3.4 ALTERATIONS TO EXISTING INSTALLATIONS
    22 - 3.5 MULTI-POINT ASPIRATING SMOKE DETECTORS
    23 - 3.6 CONTROL OF ANCILLARY DEVICES
    23 - 3.6.1 General
    23 - 3.6.2 Fire suppression system activation
    23 - 3.7 DETECTOR ALARM INDICATION
    24 - 3.8 EXTERNAL ALARM INDICATION
    24 - 3.9 FIRE INDICATOR PANEL
    24 - 3.9.1 General
    24 - 3.9.2 Covering door
    24 - 3.9.3 Remote location
    24 - 3.9.4 Clearance
    25 - 3.10 ZONE BLOCK PLAN
    25 - 3.11 CO FIRE DETECTOR LABELLING
    25 - 3.12 FIRE SUPPRESSION SYSTEM
    26 - 3.13 FLOW/PRESSURE SWITCHES
    26 - 3.14 INTERMIXING OF ACTUATING DEVICES
    26 - 3.15 MANUAL CALL POINTS
    26 - 3.16 POWER SOURCES
    26 - 3.16.1 Primary power source
    26 - 3.16.2 Secondary power source
    26 - 3.16.3 Power source rating
    27 - 3.16.4 Battery capacity
    28 - 3.16.5 Batteries and enclosure
    28 - 3.16.6 Ancillary loads
    28 - 3.17 REMOTE INDICATORS FOR FIRE DETECTORS
    28 - 3.18 REMOTE MONITORING
    28 - 3.18.1 General
    28 - 3.18.2 Alarm signalling equipment
    29 - 3.18.3 Connection
    29 - 3.19 SMOKE AND FIRE DOOR RELEASE CONTROL
    29 - 3.20 SUBINDICATOR PANEL (SIP)
    29 - 3.21 VALVE MONITORING DEVICES
    29 - 3.22 OCCUPANT WARNING
    30 - 3.23 WIRE-FREE ALARM ZONE CIRCUITS
    30 - 3.24 WIRING
    30 - 3.24.1 General
    31 - 3.24.2 Telecommunications-type cables
    31 - 3.24.3 Conductors
    31 - 3.24.4 Cable colour
    31 - 3.24.5 Terminations
    32 - 3.24.6 Joints
    32 - 3.25 LOCATION OF DETECTORS
    32 - 3.25.1 General
    33 - 3.25.2 Accessible service tunnels
    33 - 3.25.3 Air-handling systems
    33 - 3.25.4 Concealed spaces
    33 - 3.25.4.1 General
    34 - 3.25.4.2 Electrical equipment
    34 - 3.25.4.3 Remote indicators for fire detectors
    34 - 3.25.5 Cupboards
    34 - 3.25.6 Intermediate horizontal surfaces
    34 - 3.25.7 Open grid ceilings
    35 - 3.25.8 Restricted fire service access
    35 - 3.25.9 Sole occupancy units
    35 - 3.25.10 Stairwells
    35 - 3.25.11 Transportable enclosures
    35 - 3.25.12 Vertical shafts and openings
    36 - 3.26 LOCATIONS WHERE DETECTORS ARE NOT REQUIRED
    36 - 3.27 FIRE BRIGADE PANEL
    37 - 3.28 MULTI-SENSOR DETECTORS
    38 - SECTION 4 HEAT DETECTORS
    38 - 4.1 SPACING AND LOCATION OF POINT-TYPE HEAT DETECTORS
    38 - 4.1.1 General
    38 - 4.1.2 Spacing between detectors for level surfaces
    39 - 4.1.3 Spacing of detectors for sloping surfaces
    39 - 4.1.4 Spacing from walls, partitions, or air supply openings
    39 - 4.1.5 Reduced spacing
    39 - 4.1.6 Spacing in concealed spaces requiring protection
    39 - 4.2 LINEAR HEAT DETECTORS
    44 - SECTION 5 SMOKE AND CO FIRE DETECTORS
    44 - 5.1 SPACING AND LOCATION OF POINT-TYPE DETECTORS
    44 - 5.1.1 General
    44 - 5.1.2 Spacing between detectors for level surfaces
    45 - 5.1.3 Spacing between detectors for sloping surfaces
    45 - 5.1.4 Spacing from walls, partitions, or air supply openings
    46 - 5.1.5 Areas of high airflows
    46 - 5.1.6 Location of detectors on level surfaces with deep beams
    47 - 5.1.7 Spacing in concealed spaces requiring protection
    47 - 5.2 MULTI-POINT ASPIRATING SMOKE DETECTORS
    47 - 5.2.1 General
    47 - 5.2.2 System design
    53 - SECTION 6 FLAME DETECTORS
    53 - 6.1 LOCATION
    53 - 6.2 SPACING
    54 - SECTION 7 COMMISSIONING
    54 - 7.1 GENERAL
    56 - 7.2 DOCUMENTATION
    57 - 7.3 LOG
    58 - APPENDIX A - GUIDANCE FOR THE SELECTION OF DETECTORS
    58 - A1 INTRODUCTION
    58 - A2 GENERAL NOTES ON DETECTORS
    59 - A3 HEAT DETECTORS OR HEAT ALARMS
    59 - A3.1 General
    60 - A3.2 Application
    61 - A4 SMOKE DETECTORS OR SMOKE ALARMS
    61 - A4.1 General
    62 - A4.2 Application
    62 - A4.2.1 General
    62 - A4.2.2 Location considerations
    63 - A4.2.3 Ceiling surfaces
    63 - A4.2.4 Stratification
    63 - A4.2.5 Airflow
    63 - A4.2.6 Ducts
    64 - A4.2.7 Special considerations
    64 - A5 MULTI-SENSOR DETECTORS
    64 - A6 ASPIRATING SMOKE DETECTORS
    64 - A6.1 General
    64 - A6.2 Detector principles
    64 - A6.2.1 General
    65 - A6.2.2 Light scatter
    65 - A6.2.3 Particle counting
    65 - A6.3 Types
    65 - A6.3.1 General
    65 - A6.3.2 Very high sensitivity (typically for up to 2000 m 2 )
    65 - A6.3.3 Normal sensitivity (typically for a similar coverage of a single point detector)
    65 - A6.4 Pipe network and aggregation
    66 - A6.5 Flow sensing
    66 - A6.6 Dust filters detection and rejection
    66 - A6.7 Applications
    67 - A7 CARBON MONOXIDE FIRE DETECTORS
    67 - A7.1 General
    67 - A7.2 Application
    67 - A7.2.1 General
    68 - A7.2.2 Stratification
    68 - A7.2.3 Airflow
    68 - A7.2.4 Ducts
    68 - A7.2.5 Special considerations
    68 - A8 FLAME DETECTORS
    68 - A8.1 General
    69 - A8.2 Radiation sources and inhibitors
    69 - A8.2.1 General
    69 - A8.2.2 Radiation sources
    70 - A8.2.3 Radiation inhibitors
    70 - A8.3 Ultraviolet flame detection techniques
    70 - A8.3.1 Detection principles
    70 - A8.3.2 Advantages
    71 - A8.3.3 Limitations
    71 - A8.4 Single-channel infra-red detectors
    71 - A8.4.1 Detection principles
    71 - A8.4.2 Advantages
    72 - A8.4.3 Limitations
    72 - A8.5 Ultraviolet/infra-red (single-channel) flame detectors
    72 - A8.5.1 Detection principles
    72 - A8.5.2 Advantage
    72 - A8.5.3 Limitations
    73 - A8.6 Dual-channel infra-red flame detectors
    73 - A8.6.1 Detection principles
    73 - A8.6.2 Advantages
    73 - A8.6.3 Limitations
    74 - A8.7 Triple-channel infra-red flame detectors
    74 - A8.7.1 Detection principles
    74 - A8.7.2 Advantages
    75 - A8.7.3 Limitations
    76 - APPENDIX B - FIRE RATED WIRING SYSTEMS
    76 - B1 PROTECTION AGAINST EXPOSURE TO FIRE
    76 - B2 PROTECTION AGAINST MECHANICAL DAMAGE
    76 - B2.1 General
    76 - B2.2 WSXX
    76 - B2.3 WSX1
    76 - B2.4 WSX2
    77 - B2.5 WSX3
    77 - B2.6 WSX4
    77 - B2.7 WSX5
    77 - B3 PROTECTION AGAINST HOSING WITH WATER
    78 - APPENDIX C - EXAMPLES OF POWER SOURCE CAPACITY CALCULATIONS
    78 - C1 BATTERY CAPACITY CALCULATIONS
    78 - C1.1 Typical IQ calculation
    79 - C1.2 Typical IA calculation
    79 - C2 PRIMARY POWER SOURCE CALCULATIONS
    79 - C2.1 Battery charger current calculation
    80 - C2.2 Power supply requirement
    81 - APPENDIX D - FIRE ALARM SYMBOLS
    83 - APPENDIX E - COMMISSIONING TEST REPORT
    87 - APPENDIX F - STANDARD FORM OF INSTALLER’S STATEMENT FOR FIRE ALARM SYSTEM

    Abstract - (Show below) - (Hide below)

    Specifies requirements for the design, installation and commissioning of fire detection and alarm systems.

    Scope - (Show below) - (Hide below)

    This Standard sets out requirements for the design, installation and commissioning of fire detection and alarm systems comprising components complying with the requirements of the appropriate product Standards.

    General Product Information - (Show below) - (Hide below)

    Committee FP-002
    Document Type Standard
    Publisher Standards Australia
    Status AvailableSuperseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    First published as part of AS CA15-1961.Second edition 1965.Third edition 1967.Fourth edition 1971.Revised and redesignated AS 1670-1974.Second edition 1983.Revised and designated in part as AS 1670-1986.Fourth edition AS 1670-1995.Redesignated AS 1670.1-1995.AS 1670.2 first published 1997.AS 1670.1-1995 and AS 1670.2-1997 revised, amalgamated and redesignated as AS 1670.1-2004. Originated as part of AS CA15-1961. Previous edition AS 1670.1-1995. AS 1670.1-1995 and AS 1670.2-1997 revised, amalgamated and designated as AS 1670.1-2004. Reissued incorporating Amendment No. 1 (November 2005).

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 2118.4-1995 Automatic fire sprinkler systems - Residential
    AS 1603.13-1998 Automatic fire detection and alarm systems - Duct sampling units
    AS 1851.8-1987 Maintenance of fire protection equipment - Automatic fire detection and alarm systems
    AS 4029.2-1992 Stationary batteries - Lead-acid - Valve-regulated sealed type
    AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
    AS 1668.1-1991 The use of mechanical ventilation and air-conditioning in buildings - Fire and smoke control
    AS 7240.7-2004 Fire detection and alarm systems Point-type smoke detectors using scattered light, transmitted light or ionization (ISO 7240-7:2003, MOD) (Reconfirmed 2016)
    AS 1603.11-2001 Automatic fire detection and alarm systems - Visual warning devices
    AS 1603.15-2002 Automatic fire detection and alarm systems - Remote indicators
    AS 1603.2-1997 Automatic fire detection and alarm systems Point type smoke detectors (Reconfirmed 2016)
    AS 1603.8-1996 Automatic fire detection and alarm systems Multi-point aspirated smoke detectors (Reconfirmed 2016)
    AS 2659.1-1988 Guide to the use of sound measuring equipment - Portable sound level meters
    AS/NZS 3013:1995 Electrical installations - Classification of the fire and mechanical performance of wiring systems
    AS 7240.5-2004 Fire detection and alarm systems Point type heat detectors (ISO 7240-5:2003, MOD)
    AS 1603.1-1997 Automatic fire detection and alarm systems Heat detectors (Reconfirmed 2016)
    AS/NZS 4130:2003 Polyethylene (PE) pipes for pressure applications
    AS 4428.6-1997 Fire detection, warning, control and intercom systems - Control and indicating equipment - Alarm signalling equipment
    AS 1603.3-1996 Automatic fire detection and alarm systems - Heat alarms
    AS 7240.15-2004 Fire detection and alarm systems Point type fire detectors using scattered light, transmitted light or ionization sensors in combination with a heat sensor (ISO 7240-15:2004, MOD) (Reconfirmed 2016)
    AS 1259.1-1990 Acoustics - Sound level meters Non-integrating
    AS 1603.14-2001 Automatic fire detection and alarm systems - Point type carbon monoxide (CO) fire detectors
    AS 1670.4-2004 Fire detection, warning, control and intercom systems - System design, installation and commissioning Sound systems and intercom systems for emergency purposes
    AS 12239-2004 Fire detection and alarm systems - Smoke alarms (ISO 12239:2003, MOD)
    AS 2706-2003 Numerical values - Rounding and interpretation of limiting values (Reconfirmed 2018)
    AS 4428.5-1998 Fire detection, warning, control and intercom systems - Control and indicating equipment Power supply units (Reconfirmed 2016)
    AS 3786-1993 Smoke alarms
    AS 4029.3-1993 Stationary batteries - Lead-acid Pure lead positive pasted plate type
    AS 2484.2-1991 Fire - Glossary of terms Fire protection and firefighting equipment
    AS 2053-1984 Non-metallic conduits and fittings
    AS 4029.1-1994 Stationary batteries - Lead-acid Vented type (based on and including the full text of IEC 896-1)
    AS 1670.3-2004 Fire detection, warning, control and intercom systems - System design, installation and commissioning - Fire alarm monitoring
    AS 4428.9-1996 Fire detection, warning, control and intercom systems - Control and indicating equipment - Requirements for wire-free alarm zone circuits
    AS 1603.7-1996 Automatic fire detection and alarm systems Optical beam smoke detectors (Reconfirmed 2016)
    AS 2118.1-1999 Automatic fire sprinkler systems - General requirements
    AS 4428.0-1997 Fire detection, warning, control and intercom systems Control and indicating equipment - General requirements and test methods (Reconfirmed 2016)
    AS 4428.1-1998 Fire detection, warning, control and intercom systems - Control and indicating equipment Fire (Reconfirmed 2016)
    AS 1603.5-1996 Automatic fire detection and alarm systems Manual call points (Reconfirmed 2016)
    AS 7240.2-2004 Fire detection and alarm systems Control and indicating equipment (ISO 7240-2:2003, MOD)
    AS 4214-2002 Gaseous fire extinguishing systems

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 3833:2007 The storage and handling of mixed classes of dangerous goods, in packages and intermediate bulk containers
    AS 2118.3-2010 Automatic fire sprinkler systems Deluge systems
    AS 1851-2012 Routine service of fire protection systems and equipment
    AS 4326-2008 The storage and handling of oxidizing agents
    AS 2118.2-2010 Automatic fire sprinkler systems Drencher systems
    AS 1603.11-2010 Automatic fire detection and alarm systems Visual warning devices
    AS 4428.3-2004 Fire detection, warning, control and intercom systems - Control and indicating equipment - Fire brigade panel
    AS 1940-2004 The storage and handling of flammable and combustible liquids
    AS/NZS 1668.1:1998 The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings
    AS 1603.17-2011 Automatic fire detection and alarm systems Warning equipment for people with hearing impairment
    AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
    AS 3007.3-2004 Electrical installations - Surface mines and associated processing plant - General requirements for equipment and ancillaries
    AS 3786-1993 Smoke alarms
    AS 2118.6-2012 Automatic fire sprinkler systems Combined sprinkler and hydrant systems in multistorey buildings
    AS 4428.9-2006 Fire detection, warning, control and intercom systems - Control and indicating equipment - Requirements for wire-free alarm zone circuits
    AS 1428.5-2010 Design for access and mobility Communication for people who are deaf or hearing impaired (Reconfirmed 2016)
    AS 2201.2-2004 Intruder alarm systems Monitoring centres
    AS 4825-2011 Tunnel fire safety
    AS 2118.1-2006 Automatic fire sprinkler systems General systems
    AS 1851-2005 Maintenance of Fire Protection Systems and Equipment
    AS/NZS 3007:2013 Electrical equipment in mines and quarries - Surface installations and associated processing plant
    AS 4487-2013 Condensed aerosol fire extinguishing systems - Requirements for system design, installation and commissioning and test methods for components
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective