AS 1905.2-2005
Current
The latest, up-to-date edition.
Components for the protection of openings in fire-resistant walls Fire-resistant roller shutters (Reconfirmed 2016)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
09-09-2005
Specifies requirements for design, construction and installation of vertically operating roller shutters intended to protect trafficable openings in fire-rated walls. Compliance is based on prototype testing in accordance with AS1530.4. Labelling requirements are included.
Committee |
FP-019
|
DocumentType |
Standard
|
ISBN |
0 7337 6845 8
|
Pages |
7
|
ProductNote |
Reconfirmed 27/05/2016.This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 27/05/2016
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard sets out minimum requirements for the design, installation and operation of vertically operating fire-resistant roller shutters used to protect openings in walls required to resist the passage of fire.NOTES: 1 Fire resistance test requirements for roller shutters are specified in AS1530.4.2 This Standard does not address smoke leakage through shutter assemblies. Other Standards such as AS/NZS1530.7 may be used for evaluating the potential for smoke spread.
First published as AS 1905.2-1981.
Previous edition AS 1905.2-1989.
Fourth edition 2005.
AS 1530.4-1997 | Methods for fire tests on building materials, components and structures Fire-resistance tests of elements of building construction |
AS 1530.7-2007 | Methods for fire tests on building materials, components and structures Smoke control assemblies - Ambient and medium temperature leakage test procedure (Reconfirmed 2018) |
AS 1530.4-2005 | Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction |
AS 1530.1-1994 | Methods for fire tests on building materials, components and structures Combustibility test for materials (Reconfirmed 2016) |
AS/NZS 1530.7:1998 | Methods for fire tests on building materials, components and structures Smoke control door and shutter assemblies - Ambient and medium temperature leakage test procedure |
AS 1851-2012 | Routine service of fire protection systems and equipment |
AS 1530.4-2005 | Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction |
HB 37.4-1994 | Handbook of Australian fire Standards Building materials, products and construction (Reconfirmed 2016) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.