• AS 2118.3-1997

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Automatic fire sprinkler systems - Deluge

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2017

    Language(s):  English

    Published date:  01-01-1997

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 2118.3-1997 AUTOMATIC FIRE SPRINKLER SYSTEMS - DELUGE
    4 - PREFACE
    5 - CONTENTS
    6 - SECTION 1 SCOPE AND GENERAL
    6 - 1.1 SCOPE
    6 - 1.2 NEW DESIGNS AND INNOVATIONS
    6 - 1.3 REFERENCED DOCUMENTS
    7 - 1.4 DEFINITIONS
    7 - 1.4.1 Deluge valve
    7 - 1.4.2 Foam
    7 - 1.4.3 Foam concentrates
    7 - 1.4.4 Foam solution
    7 - 1.4.5 Foam/water sprinklers
    7 - 1.4.6 Multiple jet control (MJC)
    8 - 1.4.7 Open sprinklers
    8 - 1.4.8 Sealed sprinklers
    8 - 1.4.9 Standard
    9 - SECTION 2 SYSTEM CLASSIFICATION AND DESIGN
    9 - 2.1 GENERAL
    9 - 2.2 CLASSIFICATION OF OCCUPANCIES
    9 - 2.3 DESIGN DATA
    9 - 2.3.1 Area limitations
    9 - 2.3.2 Density of discharge
    9 - 2.4 WATER SUPPLIES
    9 - 2.4.1 Grade of supply
    9 - 2.4.2 Flow requirements
    10 - 2.4.3 Backflow prevention
    11 - 2.5 SPRINKLERS
    11 - 2.6 SPACING AND LOCATION OF SPRINKLERS
    11 - 2.7 HYDRAULIC CALCULATIONS
    11 - 2.8 DETECTION SYSTEMS
    11 - 2.8.1 Detectors-electrical
    11 - 2.8.2 Detectors-sprinklers
    11 - 2.9 DELUGE VALVES
    11 - 2.9.1 Location
    12 - 2.9.2 Response time
    12 - 2.9.3 Manual operation
    12 - 2.9.4 Deluge valve trim
    12 - 2.9.5 Remote test valve
    12 - 2.10 MULTIPLE JET CONTROLS (MJCs)
    12 - 2.11 DRAINAGE
    12 - 2.12 PIPE AND FITTINGS
    17 - SECTION 3 FOAM/WATER DELUGE SYSTEMS
    17 - 3.1 GENERAL
    17 - 3.2 APPLICATION
    17 - 3.3 FOAM CONCENTRATE LIMITATIONS
    17 - 3.4 SYSTEM DESIGN
    17 - 3.4.1 Design of discharge
    17 - 3.4.2 Foam concentrate storage
    17 - 3.4.3 Foam concentrate induction
    17 - 3.4.4 Location
    17 - 3.5 RESERVE SUPPLY OF FOAM CONCENTRATE
    17 - 3.5.1 Reserve supply
    18 - 3.5.2 Compatibility of reserve supply
    18 - 3.6 RETENTION AND DISPOSAL
    18 - 3.7 MONITORING
    22 - SECTION 4 COMPONENTS
    22 - 4.1 GENERAL
    22 - 4.2 FOAM CONCENTRATE
    22 - 4.3 FOAM CONCENTRATE PROPORTIONING
    22 - 4.3.1 Proportioning system
    22 - 4.3.2 Orifice plates
    22 - 4.4 TEST CONNECTIONS
    22 - 4.5 FOAM CONCENTRATE STORAGE TANKS
    22 - 4.5.1 Storage tanks, pipes and fittings
    22 - 4.5.2 Storage temperature
    22 - 4.5.3 Atmospheric-type storage tanks
    23 - 4.5.4 Pressure-type storage tanks
    23 - 4.6 STRAINERS FOR FOAM CONCENTRATES
    23 - 4.6.1 Strainer location
    23 - 4.6.2 Strainer size
    23 - 4.7 FOAM CONCENTRATE PUMPS
    23 - 4.7.1 Materials
    23 - 4.7.2 Capacity
    23 - 4.7.3 Pressure relief
    23 - 4.7.4 Flushing
    23 - 4.7.5 Shut-off

    Abstract - (Show below) - (Hide below)

    Sets out requirements for the operation of specialized sprinkler installations designed to function in hazardous environments such as flammable liquid stores where open sprinklers deliver water or foam rapidly when quick opening valves operate following detection of flame, heat or smoke.

    Scope - (Show below) - (Hide below)

    This Standard specifies requirements for the installation and performance of deluge fire sprinkler systems within buildings, with or without foam concentrate induction.These systems are not suitable for use on materials that will react violently with water (e.g. metallic sodium), or which produce hazardous materials by reacting with water, or on fires involving electrical equipment where the electrical non-conductivity of the extinguishing agent is of first importance.Water spray deluge systems employing medium or high velocity sprayer nozzles are not covered by this Standard.

    General Product Information - (Show below) - (Hide below)

    Committee FP-004
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    First published as AS 2118.3-1997.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 2484.2-1991 Fire - Glossary of terms Fire protection and firefighting equipment
    AS 2118.1-1995 Automatic fire sprinkler systems - Standard
    AS 4118.1.1-1996 Fire sprinkler systems Components - Sprinklers and sprayers (Reconfirmed 2013)
    AS 3500.1-1992 National Plumbing and Drainage Code - Water supply
    AS 1940-1993 The storage and handling of flammable and combustible liquids
    AS 3500.0-1990 National Plumbing and Drainage Code Glossary of terms
    AS 1670-1986 Automatic fire detection and alarm systems - System design, installation, and commissioning
    AS 4118.2.1-1995 Fire sprinkler systems Piping - General (Reconfirmed 2013)
    AS 2118.9-1995 Automatic fire sprinkler systems Piping support and installation (Reconfirmed 2013)
    AS 2484.1-1990 Fire - Glossary of terms Fire tests (Reconfirmed 2016)
    AS 4118.1.5-1996 Fire sprinkler systems Components - Deluge and pre-action valves (Reconfirmed 2013)

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 3833:2007 The storage and handling of mixed classes of dangerous goods, in packages and intermediate bulk containers
    AS 3846-2005 The handling and transport of dangerous cargoes in port areas
    SAA HB20-1996 Graphical symbols for fire protection drawings (Reconfirmed 2018)
    HB 147-2000 Sprinklers Simplified
    AS 1940-2004 The storage and handling of flammable and combustible liquids
    AS 2441-2005 Installation of fire hose reels (Reconfirmed 2018)
    AS/NZS 2022:2003 Anhydrous ammonia - Storage and handling (Reconfirmed 2023)
    AS 2941-2008 Fixed fire protection installations - Pumpset systems
    AS 2714-2008 The storage and handling of organic peroxides (Reconfirmed 2021)
    AS 3007.3-2004 Electrical installations - Surface mines and associated processing plant - General requirements for equipment and ancillaries
    AS/NZS 4681:2000 The storage and handling of Class 9 (miscellaneous) dangerous goods and articles
    AS 4332-2004 The storage and handling of gases in cylinders (Reconfirmed 2016)
    AS 2118.1-2006 Automatic fire sprinkler systems General systems
    AS 1851-2005 Maintenance of Fire Protection Systems and Equipment
    AS 2444-2001 Portable fire extinguishers and fire blankets - Selection and location (Reconfirmed 2021)
    AS 2665-2001 Smoke/heat venting systems - Design, installation and commissioning (Reconfirmed 2016)
    AS/NZS 4081:2001 The storage and handling of liquid and liquefied polyfunctional isocyanates (Reconfirmed 2021)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective