1 - AS 2118.5-1995 AUTOMATIC FIRE SPRINKLER SYSTEMS - DOMESTIC
4 - PREFACE
6 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 NEW DESIGNS AND INNOVATIONS
7 - 1.3 REFERENCED DOCUMENTS
7 - 1.4 DEFINITIONS
7 - 1.4.1 Class 1 building
7 - 1.4.2 Compartment
8 - 1.4.3 Design discharge
8 - 1.4.4 Listed
8 - 1.4.5 Residential sprinkler
8 - 1.5 APPLICATION
9 - SECTION 2 DESIGN AND INSTALLATION REQUIREMENTS
9 - 2.1 GENERAL
9 - 2.2 WORKING DRAWINGS
9 - 2.2.1 General
9 - 2.2.2 Approval requirements
10 - 2.2.3 Acceptance tests
10 - 2.2.4 Compliance requirements
10 - 2.3 WATER SUPPLY
10 - 2.3.1 General
10 - 2.3.2 Connection to town main
11 - 2.3.3 Connection to private water supplies
11 - 2.3.4 Pumpset
11 - 2.4 DESIGN CRITERIA
11 - 2.4.1 Design discharge
11 - 2.4.2 Design number of sprinklers
11 - 2.4.3 Water demand
12 - 2.5 SPRINKLERS
12 - 2.5.1 Types of sprinklers
12 - 2.5.2 Temperature ratings
12 - 2.5.3 Normal temperature ratings
12 - 2.5.4 Compatibility
12 - 2.5.5 Positioning of sprinklers
12 - 2.5.6 Positioning of sprinklers under skylights
12 - 2.6 SYSTEM TYPES
12 - 2.6.1 Wet systems
12 - 2.6.2 Systems subject to freezing
12 - 2.7 PIPE SIZING
12 - 2.7.1 General
12 - 2.7.2 Minimum pipe size
14 - 2.7.3 Pipe sizing for towns main systems
14 - 2.7.4 Pipe sizing for stored water supplies
14 - 2.8 PIPING LAYOUTS
14 - 2.9 EXTENT OF SPRINKLER PROTECTION
18 - SECTION 3 MARKING AND IDENTIFICATION
18 - 3.1 IDENTIFICATION
18 - 3.2 SITE PLAN
18 - 3.3 STOCK OF REPLACEMENT SPRINKLERS
18 - 3.4 OPERATING INSTRUCTIONS
19 - SECTION 4 COMPONENTS
19 - 4.1 GENERAL
19 - 4.2 VALVE AND DRAINS
19 - 4.3 PRESSURE GAUGES
19 - 4.4 PIPING
19 - 4.5 PIPING SUPPORT
19 - 4.6 SPRINKLERS
19 - 4.6.1 Types of sprinklers
19 - 4.7 PAINTING AND ORNAMENTAL FINISHES
19 - 4.8 ALARMS
20 - APPENDIX A - RECOMMENDED SMOKE DETECTOR REQUIREMENTS
21 - APPENDIX B - COMPLETION CERTIFICATE
22 - APPENDIX C - MAINTENANCE
22 - C1 MAINTENANCE

Specifies requirements for the design and installation of automatic life safety fire sprinkler systems for buildings defined as Class 1 in accordance with the Building Code of Australia.

Committee
FP-004
DocumentType
Standard
ISBN
0 7262 9739 9
Pages
16
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies requirements for the design and installation and performance of automatic life safety fire sprinkler systems for buildings defined as Class 1 in accordance with the Building Code of Australia (BCA).

First published as AS 2118.5-1995.

AS 1851.3-1997 Maintenance of fire protection equipment Automatic fire sprinkler systems
AS 3013-1990 Electrical installations - Wiring systems for specific applications
AS 3500.0-1990 National Plumbing and Drainage Code Glossary of terms
AS 3786-1993 Smoke alarms
AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
AS 2118.1-2006 Automatic fire sprinkler systems General systems
AS/NZS 3013:2005 Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020)
AS 4118.2.1-1995 Fire sprinkler systems Piping - General (Reconfirmed 2013)
AS 2941-2002 Fixed fire protection installations - Pumpset systems
AS 2484.1-1990 Fire - Glossary of terms Fire tests (Reconfirmed 2016)
AS/NZS 3500.0:2003 Plumbing and drainage Glossary of terms
AS 2118.9-1995 Automatic fire sprinkler systems Piping support and installation (Reconfirmed 2013)
AS 1851.3-1985 Maintenance of fire protection equipment - Automatic fire sprinkler systems
AS 2941-1995 Fixed fire protection installations - Pumpset systems
AS 2484.2-1991 Fire - Glossary of terms Fire protection and firefighting equipment
AS 2118.1-1995 Automatic fire sprinkler systems - Standard

AS/NZS 3833:2007 The storage and handling of mixed classes of dangerous goods, in packages and intermediate bulk containers
AS 3846-2005 The handling and transport of dangerous cargoes in port areas
AS 2941-2002 Fixed fire protection installations - Pumpset systems
SAA HB20-1996 Graphical symbols for fire protection drawings (Reconfirmed 2018)
HB 147-2000 Sprinklers Simplified
AS 2441-2005 Installation of fire hose reels (Reconfirmed 2018)
AS 4809-2003 Copper pipe and fittings - Installation and commissioning
AS/NZS 2022:2003 Anhydrous ammonia - Storage and handling (Reconfirmed 2023)
AS 2118.9-1995 Automatic fire sprinkler systems Piping support and installation (Reconfirmed 2013)
AS 2941-2008 Fixed fire protection installations - Pumpset systems
AS 3007.3-2004 Electrical installations - Surface mines and associated processing plant General requirements for equipment and ancillaries
AS/NZS 4681:2000 The storage and handling of Class 9 (miscellaneous) dangerous goods and articles
AS 4332-2004 The storage and handling of gases in cylinders (Reconfirmed 2016)
AS 1851.14-1996 Maintenance of fire protection equipment - Pumpset systems
AS 2941-1995 Fixed fire protection installations - Pumpset systems
AS 1851-2005 Maintenance of Fire Protection Systems and Equipment
AS 2444-2001 Portable fire extinguishers and fire blankets - Selection and location (Reconfirmed 2021)
AS 2665-2001 Smoke/heat venting systems - Design, installation and commissioning (Reconfirmed 2016)
AS/NZS 4081:2001 The storage and handling of liquid and liquefied polyfunctional isocyanates (Reconfirmed 2021)