AS 2252.2-1994
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Biological safety cabinets - Laminar flow biological safety cabinets (Class II) for personnel, environment and product protection
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
25-06-2021
English
01-01-1994
Specifies requirements for laminar flow cabinets intended to provide protection from hazardous biological agents for personnel, the environment and to protect material used in the cabinet from contamination. Construction, air characteristic, acoustic, lighting and vibration requirements are given.
Committee |
ME-060
|
DocumentType |
Standard
|
ISBN |
0 7262 8829 2
|
Pages |
10
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard specifies requirements for Class II laminar flow biological safety cabinets which are intended to provide protection from hazardous biological agents for personnel and the environment and also to protect material used in the cabinet from exogenous contamination. The cabinets provide protection by inducing an inflow of air through the work access opening, by delivering recirculated, filtered, laminar flow air downwards through the work zone and by high efficiency particulate air (HEPA) filtration of exhaust air.This Standard should be read in conjunction with AS 2647 which describes recommended practices for installation and use of these cabinets.NOTES:1 These cabinets are intended only for handling materials which can be neutralized or rendered safe by an effective decontamination procedure such as that described in AS 2647.2 Additional design requirements may apply to cabinets which are required to afford protection against other hazards such as toxic materials not of biological origin or against radiation.3 For work with cytotoxic drugs the user is referred to AS 2567.
First published as AS 2252.2-1980.
Second edition 1985.
Third edition 1994.
AS 1807.5-1989 | Cleanrooms, workstations and safety cabinets - Methods of test Determination of work zone integrity |
AS 1807.2-1989 | Cleanrooms, workstations and safety cabinets - Methods of test Determination of performance of clean workstations and laminar flow safety cabinets under loaded filter conditions |
AS 1939-1990 | Degrees of protection provided by enclosures for electrical equipment (IP Code) |
AS 1807.22-1989 | Cleanrooms, workstations and safety cabinets - Methods of test Determination of air barrier containment of laminar flow safety cabinets |
AS 1319-1994 | Safety signs for the occupational environment (Reconfirmed 2018) |
AS 3000-1986 | Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules) |
AS 1807.1-1989 | Cleanrooms, workstations and safety cabinets - Methods of test Determination of air velocity and uniformity of air velocity in clean workstations and laminar flow safety cabinets |
AS 2252.1-1994 | Biological safety cabinets - Biological safety cabinets (Class I) for personnel and environment protection |
AS 2647-1994 | Biological safety cabinets - Installation and use |
AS 2567-1994 | Laminar flow cytotoxic drug safety cabinets |
AS 1807.18-1989 | Cleanrooms, workstations and safety cabinets - Methods of test Determination of vibration in workstations and safety cabinets |
AS 3100-1990 | Approval and test specification - General requirements for electrical equipment |
AS 2107-1987 | Acoustics - Recommended design sound levels and reverberation times for building interiors |
AS 1807.23-1989 | Cleanrooms, workstations and safety cabinets - Methods of test Determination of intensity of radiation from germicidal ultraviolet lamps |
AS 2659.1-1988 | Guide to the use of sound measuring equipment - Portable sound level meters |
AS 1807.6-1989 | Cleanrooms, workstations and safety cabinets - Methods of test Determination of integrity of terminally mounted HEPA filter installations |
AS 1324-1973 | Air filters for use in air conditioning and general ventilation |
AS 2243.3-1985 | Safety in laboratories - Microbiology |
AS 1807.15-1989 | Cleanrooms, workstations and safety cabinets - Methods of test Determination of illuminance |
AS/NZS 2243.3:2002 | Safety in laboratories Microbiological aspects and containment facilities |
AS 2647-1994 | Biological safety cabinets - Installation and use |
AS/NZS 2243.9:2003 | Safety in laboratories - Recirculating fume cabinets |
AS/NZS 2243.1:1997 | Safety in laboratories General |
AS 4276.1-1995 | Water microbiology General information and procedures |
AS/NZS 2869:1998 | Tampons - Menstrual |
AS 4479.1-1997 | Analysis of soil Pretreatment of potentially contaminated soil samples for heavy metal and metalloid analysis |
AS/NZS 2869:1995 | Tampons - Menstrual |
AS/NZS 2647:2000 | Biological safety cabinets - Installation and use |
AS/NZS 2982.1:1997 | Laboratory design and construction General requirements |
AS/NZS 2243.3:1995 | Safety in laboratories Microbiology |
AS 1807.22-2000 | Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air barrier containment of laminar flow safety cabinets |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.