• There are no items in your cart

AS 2252.2-2009

Current

Current

The latest, up-to-date edition.

Controlled environments Biological safety cabinets Class II - Design

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

02-11-2009

€57.40
Excluding VAT

Specifies basic requirements for Class II laminar flow biological safety cabinets that are intended to provide protection from hazardous biological agents for personnel and the environment and also to protect material use in the cabinet from exogenous contamination.

Committee
ME-060
DocumentType
Standard
ISBN
0 7337 9290 1
Pages
15
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies basic requirements for Class II laminar flow biological safety cabinets that are intended to provide protection from hazardous biological agents for personnel and the environment and also to protect material used in the cabinet from exogenous contamination. The cabinets provide protection by inducing an inflow of room air through the work access opening, by delivering recirculated, high efficiency particulate air (HEPA) filtered, laminar flow air downwards through the work zone and by HEPA filtration of exhaust air.It is intended that this Standard be read in conjunction with AS 2252.4 which describes recommended practices for installation and use of these cabinets.NOTES:1 These cabinets are intended only for handling materials that can be inactivated or rendered safe by an effective decontamination procedure such as that described in AS 2252.4 .2 Additional design requirements may apply to cabinets that are required to afford protection against other hazards such as toxic materials not of biological origin or against radiation.3 For work with cytotoxic drugs the user is referred to AS 2252.5.4 Consideration of ergonomics for the design and selection of biological safety cabinets are addressed in Appendix A.

Originated as AS 2252.2-1980.
Previous edition 2004.
Fifth edition 2009.
Reissued incorporating Amendment No. 1 (June 2010).

AS 1807.13-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of relative humidity in cleanrooms
AS 1807.23-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of intensity of radiation from germicidal ultraviolet lamps
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 1807.10-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air pressure of cleanrooms and pharmaceutical isolators
AS 1807.26-2004 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air barrier containment of laminar flow safety cabinets - Potassium iodidediscus test
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 4260-1997 High efficiency particulate air (HEPA) filters - Classification, construction and performance (Reconfirmed 2018)
AS 1807.22-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air barrier containment of laminar flow safety cabinets
AS/NZS 2243.3:2002 Safety in laboratories Microbiological aspects and containment facilities
AS 1807.20-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of sound level at installed workstations, safety cabinets and pharmaceutical isolators
AS 1807.12-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of temperature in work zones
AS 1807.11-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of airflow parallelism in laminar flow cleanrooms
AS 1319-1994 Safety signs for the occupational environment (Reconfirmed 2018)
AS 1807.16-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of sound level in cleanrooms
AS 1807.1-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air velocity and uniformity of air velocity in clean workstations, laminar flow safety cabinets and pharmaceutical isolators
AS 1807.15-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of illuminance
AS/NZS 2107:2000 Acoustics - Recommended design sound levels and reverberation times for building interiors
AS 1807.5-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of work zone integrity
AS 1807.18-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of vibration in workstations, safety cabinets and pharmaceutical isolators
AS 1807.17-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of vibration in cleanrooms
AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment
AS 1807.6-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of integrity of terminally mounted HEPA filter installations

AS/NZS 2982:2010 Laboratory design and construction
AS/NZS 2243.8:2014 Safety in laboratories Fume cupboards
AS 4125.1-2009 Sound laboratory practice in food and water microbiology laboratories - Premises, safety, sample management, regulatory compliance and record management
AS 2252.6-2011 Controlled environments Clean workstations - Design, installation and use
AS/NZS 2243.3:2010 Safety in laboratories Microbiological safety and containment

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.