AS 2567-2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Laminar flow cytotoxic drug safety cabinets
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
01-08-2017
English
01-01-2002
Specifies requirements for open-fronted laminar flow cytotoxic drug safety cabinets which are intended to provide protection for personnel, the environment, and cytotoxic drug products
Committee |
ME-060
|
DocumentType |
Standard
|
ISBN |
0 7337 4826 0
|
Pages |
14
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard specifies requirements for open-fronted laminar flow cytotoxic drug safety cabinets which are intended to provide protection for personnel, the environment, and cytotoxic drug products. These cabinets may also find wider application for handling other hazardous drugs and materials (see AS 2639). They are primarily designed to contain aerosols, and are not intended to provide complete protection against particles which may be ejected during procedures such as tablet crushing and grinding. This Standard should be read in conjunction with AS 2639 which describes recommended practices for installation and use of these cabinets. NOTE: Ergonomic considerations for the design and use of cytotoxic drug safety cabinets are addressed in Appendix A.
First published as AS 2567-1982.
Second edition 1994.
Third edition 2002.
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 4260-1997 | High efficiency particulate air (HEPA) filters - Classification, construction and performance (Reconfirmed 2018) |
AS 1324.2-2003 | Air filters for use in general ventilation and airconditioning Methods of test |
AS 1324.2-1996 | Air filters for use in general ventilation and airconditioning Methods of test |
AS 1939-1990 | Degrees of protection provided by enclosures for electrical equipment (IP Code) |
AS 1807.22-2000 | Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air barrier containment of laminar flow safety cabinets |
AS 1807.6-2000 | Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of integrity of terminally mounted HEPA filter installations |
AS 2639-1994 | Laminar flow cytotoxic drug safety cabinets - Installation and use |
AS 1807.15-2000 | Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of illuminance |
AS/NZS 2107:2000 | Acoustics - Recommended design sound levels and reverberation times for building interiors |
AS 1807.5-2000 | Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of work zone integrity |
AS 1807.18-2000 | Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of vibration in workstations, safety cabinets and pharmaceutical isolators |
AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
AS 2659.1-1988 | Guide to the use of sound measuring equipment - Portable sound level meters |
AS 1319-1994 | Safety signs for the occupational environment (Reconfirmed 2018) |
AS 1807.1-2000 | Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air velocity and uniformity of air velocity in clean workstations, laminar flow safety cabinets and pharmaceutical isolators |
AS 1807.2-2000 | Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of performance of clean workstations, laminar flow safety cabinets and pharmaceutical isolators under loaded filter conditions |
AS/NZS 2243.3:2002 | Safety in laboratories Microbiological aspects and containment facilities |
AS/NZS 4020:2002 | Testing of products for use in contact with drinking water |
AS/NZS 2982:2010 | Laboratory design and construction |
AS 1386.1-1989 | Cleanrooms and clean workstations - Principles of clean space control |
AS 2252.1-2002 | Biological safety cabinets - Biological safety cabinets (Class I) for personnel and environment protection |
AS/NZS 2243.8:2014 | Safety in laboratories Fume cupboards |
AS 2639-1994 | Laminar flow cytotoxic drug safety cabinets - Installation and use |
AS 2252.2-2004 | Biological safety cabinets - Laminar flow biological safety cabinets (Class II) for personnel, environment and product protection |
AS/NZS 2243.8:2006 | Safety in laboratories - Fume cupboards |
AS/NZS 2647:2000 | Biological safety cabinets - Installation and use |
AS/NZS 2243.1:2005 | Safety in laboratories Planning and operational aspects |
AS/NZS 4020:2018 | Testing of products for use in contact with drinking water |
AS 1386.5-1989 | Cleanrooms and clean workstations - Clean workstations |
AS/NZS 2243.3:2010 | Safety in laboratories Microbiological safety and containment |
AS 2252.5:2017 | Controlled environments Cytotoxic drug safety cabinets (CDSC) - Design, construction, installation, testing and use |
AS 3578-1993 | Cast iron non-return valves for general purposes |
AS/NZS 4020:2005 | Testing of products for use in contact with drinking water |
AS 1807.22-2000 | Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air barrier containment of laminar flow safety cabinets |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.