AS 3560-1991
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electric cables - XLPE insulated - Aerial bundled - For working voltages up to and including 0.6/1 kV
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
25-05-2024
01-01-1991
Specifies the construction, dimensions and tests for two, three and four core aerial bundled cables having aluminium conductor sizes between 16 mm(sup)2 and 150 mm(sup)2.
Committee |
EL-003
|
DocumentType |
Standard
|
ISBN |
0 7262 6870 4
|
Pages |
21
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This Standard specifies the construction, dimensions and tests for 0.6/1 kV rated cross-linked polyethylene (XLPE) insulated aerial bundled cables (ABC) of 2, 3 or 4 cores having aluminium conductors with cross-sectional areas of 16 mm2to 150 mm2. It provides for two types of cable, one being insulated with the standard grade of XLPE and one comprising improved performance grade XLPE insulation designed for installation in bushfire-prone areas.Both types of cable are designed for use with mechanical fittings for aerial bundled cables specified in AS 3766.Cable construction, identification and preparation for delivery requirements are specified in Section 2 and tests in Section 3.A guide to cable selection and technical data is provided in Appendix E.
Under Revision see DR 97545
AS/NZS 3198:1996 | Approval and test specification - Electric cables - XLPE insulated - For working voltages up to and including 0.6/1 kV |
AS/NZS 4396:1999 | Connectors - Insulation piercing - For 0.6/1 kV aerial bundled cables |
AS 3947.3 SUPP 1-1995 | Low-voltage switchgear and controlgear Switches, disconnectors, switch-disconnectors and fuse-combination units - Fuse-switch-disconnectors and switch-disconnectors for use with low-voltage aerial bundled cables (Supplement to AS 3947.3-1994) |
AS/NZS 3808:1998 | Insulating and sheathing materials for electric cables |
AS/NZS 3008.1.2:1998 | Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions |
AS 3766-1990 | Mechanical fittings for low voltage aerial bundled cables |
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 3012:1995 | Electrical installations - Construction and demolition sites |
AS/NZS 3008.1.1:1998 | Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS 3675-1993 | Conductors - Covered overhead - For working voltages 6.35/11 kV up to and including 19/33 kV |
AS/NZS 4396(INT):1996 | Connectors - Insulation piercing - For 0.6/1 kV aerial bundled cables |