• AS/NZS 3198:1996

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Approval and test specification - Electric cables - XLPE insulated - For working voltages up to and including 0.6/1 kV

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2017

    Language(s):  English

    Published date:  01-01-1996

    Publisher:  Standards Australia

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Specifies construction, dimensions and tests for cables insulated with cross-linked polyethylene (XLPE), intended for use in electrical installations at working voltages up to and including 0.6/1 kV. It does not apply to specialized XLPE insulated cables for which there are separate Australian, New Zealand or Australian/New Zealand Standards, e.g. concentric wire neutral cables, neutral screened cables, aerial bundled cables and the like.

    Scope - (Show below) - (Hide below)

    This Standard specifies construction, dimensions and tests for cables insulated with three types of cross-linked polyethylene (XLPE), two of which have reduced combustion propagation characteristics. The cables are intended for use in electrical installations at working voltages up to and including 0.6/1 KV.Except where otherwise specified in tables of construction and dimensions, cables covered by this Standard are suitable for use as underground cables.This Standard does not apply to specialized XLPE insulated cables for which there are separate Australian, New Zealand or Australian/New Zealand Standards, e.g. concentric wire neutral cables, neutral screened cables, aerial bundled cables and the like.In addition to providing detailed requirements for cables of the types and sizes in the tables of construction and dimensions, this Standard provides the basis of requirements for other types and sizes in the range of materials covered by this Standard.NOTE: Purchasing guidelines are contained in Appendix A.

    General Product Information - (Show below) - (Hide below)

    Committee EL-003
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes

    History - (Show below) - (Hide below)

    First published in Australia as AS 3198-1977.Second edition 1990.First published in New Zealand as NZS/AS 3198-1990.Jointly revised and designated as AS/NZS 3198:1996. First published in Australia as AS 3198-1977. Second edition 1990. First published in New Zealand as NZS/AS 3198-1990. Jointly revised and designated as AS/NZS 3198:1996.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 1125-1993 Conductors in insulated electric cables and flexible cords
    AS 2893-1986 Electric cables - Lead and lead alloy sheaths - Composition
    AS 1178-1986 Concentric wire neutral cables - XLPE insulated - For electricity supply at working voltages of 0.6/1 kV
    AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
    AS 3155-1986 Approval and test specification - Neutral screened cables for working voltages of 0.6/1 kV
    AS 3560-1991 Electric cables - XLPE insulated - Aerial bundled - For working voltages up to and including 0.6/1 kV
    AS 2122.1-1993 Combustion characteristics of plastics Determination of flame propagation - Surface ignition of vertically oriented specimens of cellular plastics
    AS 3863-1991 Galvanized mild steel wire for armouring cables

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 3155:1995 Approval and test specification - Electric cables - Neutral screened - For working voltages up to and including 0.6/1 kV
    AS 2067-1984 Switchgear assemblies and ancillary equipment for alternating voltages above 1 kV
    AS 2697-1990 Jumper leads for automotive starting
    AS/NZS 3808:1998 Insulating and sheathing materials for electric cables
    AS/NZS 3008.1.2:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions
    AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
    AS/NZS 3008.1.1:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
    SAA HB37.2-1993 Handbook of Australian fire Standards Electrical equipment (Reconfirmed 2016)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective