• AS 4118.1.4-1994

    Current The latest, up-to-date edition.

    Fire sprinkler systems Components - Valve monitors (Reconfirmed 2013)

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  17-01-1994

    Publisher:  Standards Australia

    Add To Cart

    Description - (Show below) - (Hide below)

    This Standard has been reconfirmed. To view or download the Reconfirmation Notice please click here.

    Table of Contents - (Show below) - (Hide below)

    1 - AS 4118.1.4:1994 FIRE SPRINKLER SYSTEMS - COMPONENTS - VALVE MONITORS
    4 - PREFACE
    5 - CONTENTS
    6 - SECTION 1 - SCOPE AND GENERAL
    6 - 1.1 SCOPE
    6 - 1.2 REFERENCED DOCUMENTS
    7 - 1.3 DEFINITIONS
    7 - 1.3.1 Alarm initiation-
    7 - 1.3.2 Supervisory equipment (SE)-
    7 - 1.3.3 Stop valve-
    7 - 1. 3.4 Transmit an alarm-
    7 - 1.3.5 Valve operating mechanism-
    7 - 1.3.6 Watching station-
    8 - SECTION 2 - MATERIAL AND DESIGN REQUIREMENTS
    8 - 2.1 SCOPE OF SECTION
    8 - 2.2 DESIGN AND CONSTRUCTION
    8 - 2.3 MATERIALS AND COMPONENTS
    9 - 2.4 CONNECTING FACILITIES
    9 - 2.5 INTERNAL WIRING
    9 - 2.6 CONTACTS
    9 - 2.7 CONNECTION OF MULTIPLE MONITORS
    10 - SECTION 3 - PERFORMANCE REQUIREMENTS
    10 - 3.1 SCOPE OF SECTION
    10 - 3.2 TAMPER RESISTANCE REQUIREMENTS
    10 - 3.2.1 Tamper resistance
    10 - 3.2.2 Integrity of signalling path
    10 - 3.2.3 Subversion by physical damage
    10 - 3.3 NORMAL OPERATION
    10 - 3.4 ELECTRICAL REQUIREMENTS
    10 - 3.4.1 Voltage stability
    10 - 3.4.2 Insulation resistance
    10 - 3.4.3 Static discharge
    10 - 3.4.4 Electromagnetic interference
    10 - 3.4.5 Impulse voltage withstand
    10 - 3.4.6 High frequency disturbance
    10 - 3.5 ENVIRONMENTAL REQUIREMENTS
    10 - 3.5.1 Low temperature
    10 - 3.5.2 Damp heat
    11 - 3.5.3 Dry heat
    11 - 3.5.4 Corrosion
    11 - 3.5.5 Salt mist
    11 - 3.5.6 Dust
    11 - 3.6 VIBRATION, IMPACT AND ENDURANCE REQUIREMENTS
    11 - 3.6.1 Vibration
    11 - 3.6.2 Impact
    11 - 3.6.3 Endurance requirement
    12 - SECTION 4 - PRODUCT MARKING AND INFORMATION
    12 - 4.1 SCOPE OF SECTION
    12 - 4.2 MARKING
    12 - 4.3 INFORMATION
    12 - 4.4 POINT OF SALE INFORMATION
    13 - SECTION 5 - ASSESSMENT FOR COMPLIANCE
    13 - 5.1 SCOPE OF SECTION
    13 - 5.2 TEST SCHEDULE AND CRITERIA OF ACCEPTANCE
    13 - 5.3 REPORTING
    15 - APPENDIX A - TAMPER RESISTANCE EVALUATION
    15 - A1 SCOPE
    15 - A2 PRINCIPLE
    15 - A3 APPARATUS
    15 - A4 PROCEDURE
    15 - A5 REQUIREMENTS
    16 - APPENDIX B - NORMAL OPERATION TEST
    16 - B1 SCOPE
    16 - B2 PRINCIPLE
    16 - B3 APPARATUS
    16 - B4 PROCEDURE
    16 - B5 REQUIREMENTS
    17 - APPENDIX C - ENDURANCE TEST
    17 - C1 SCOPE
    17 - C2 PRINCIPLE
    17 - C3 APPARATUS
    17 - C4 PROCEDURE

    Abstract - (Show below) - (Hide below)

    Specifies the requirements for establishing compliance with limits of design, performance, security and durability for sprinkler and hydrant valve monitors.

    Scope - (Show below) - (Hide below)

    This Standard specifies the requirements for valve monitors for mounting on stop valves for automatic fire prinkler systems, designed and installed in compliance with AS 2118, and fire hydrant systems designed and installed in compliance with AS 2419, to monitor the set position of the valves. If the state of a valve is changed or an attempt is made to subvert the operation of the monitor it will initiate an alarm signal.NOTE: The alarm signal is generally initiated and then transmitted via the supervisory equipment to a fire control station or a monitoring station.

    General Product Information - (Show below) - (Hide below)

    Committee FP-004
    Document Type Standard
    Product Note Reconfirmed 10-07-2013
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    First published as AS 4118.1.4-1994.Reconfirmed 2013. First published as AS 4118.1.4-1994.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 2362.4-1993 Automatic fire detection and alarm systems - Methods of test for actuating devices - Voltage stability test
    AS 2362.6-1993 Automatic fire detection and alarm systems - Methods of test for actuating devices - Static discharge test
    AS 3121-1992 Approval and test specification - Insulating mouldings
    AS 2362.8-1990 Automatic fire detection and alarm systems - Methods of test for actuating devices - Impulse voltage withstand test
    AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment
    AS 2201.2-2004 Intruder alarm systems Monitoring centres
    AS 3100-1990 Approval and test specification - General requirements for electrical equipment
    AS 2419.1-1994 Fire hydrant installations - System design, installation and commissioning
    AS 2362.7-1990 Automatic fire detection and alarm systems - Methods of test for actuating devices - Electromagnetic interference test
    AS 3013-1990 Electrical installations - Wiring systems for specific applications
    AS 2362.10-2002 Fire detection, warning, control and intercom systems - Methods of test Low temperature test (Reconfirmed 2016)
    AS 2362.19-1990 Automatic fire detection and alarm systems - Methods of test for actuating devices - Dust test
    AS 2362.5-1990 Automatic fire detection and alarm systems - Methods of test for actuating devices - Insulation resistance test
    AS 2362.12-2002 Fire detection, warning, control and intercom systems Methods of test - Dry heat test (Reconfirmed 2016)
    AS 2118-1982 Automatic fire sprinkler systems (known as the SAA Code for Automatic Fire Sprinkler Systems)
    AS 2362.12-1990 Automatic fire detection and alarm systems - Methods of test for actuating devices - Dry heat test
    AS 2362.16-2002 Fire detection, warning, control and intercom systems Methods of test - Impact test (Reconfirmed 2016)
    AS 2362.11-1990 Automatic fire detection and alarm systems - Methods of test for actuating devices - Damp heat test
    AS/NZS 3121:2002 Approval and test specification - Insulating mouldings (Reconfirmed 2020)
    AS 2362.13-1993 Automatic fire detection and alarm systems - Methods of test for actuating devices - Corrosion test
    AS 2362.13-2002 Fire detection, warning, control and intercom systems Methods of test - Corrosion test (Reconfirmed 2016)
    AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
    AS 2362.15-2002 Fire detection, warning, control and intercom systems Methods of test - Vibration test (Reconfirmed 2016)
    AS 1099.2KA-1978 Basic environmental testing procedures for electrotechnology Tests - Test Ka - Salt mist
    AS 2362.19-2002 Fire detection, warning, control and intercom systems Methods of test - Dust test (Reconfirmed 2016)
    AS 2201.2-1992 Intruder alarm systems - Central stations
    AS/NZS 3013:2005 Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020)
    AS 2362.11-2002 Fire detection, warning, control and intercom systems Methods of test - Damp heat test
    AS 2362.10-1990 Automatic fire detection and alarm systems - Methods of test for actuating devices - Low temperature test
    AS 2362.9-1990 Automatic fire detection and alarm systems - Methods of test for actuating devices - High frequency disturbance test
    AS 2362.15-1993 Automatic fire detection and alarm systems - Methods of test for actuating devices - Vibration test
    AS 2362.16-1990 Automatic fire detection and alarm systems - Methods of test for actuating devices - Impact test
    AS 2380.1-1989 Electrical equipment for explosive atmospheres - Explosion-protection techniques General requirements (Reconfirmed 2013)

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 2118.1:2017 Automatic fire sprinkler systems General systems
    AS 2419.1:2017 Fire hydrant installations System design, installation and commissioning
    HB 147-2000 Sprinklers Simplified
    AS 4041-2006 Pressure piping (Reconfirmed 2016)
    AS 2118.6-1995 Automatic fire sprinkler systems - Combined sprinkler and hydrant
    AS 2118.2-1995 Automatic fire sprinkler systems - Wall wetting sprinklers (Drenchers)
    AS 2118.6-2012 Automatic fire sprinkler systems Combined sprinkler and hydrant systems in multistorey buildings
    AS 2118.1-1995 Automatic fire sprinkler systems - Standard
    AS 2419.1-1994 Fire hydrant installations - System design, installation and commissioning
    AS 2118.1-2006 Automatic fire sprinkler systems General systems
    AS/NZS 3500.1:2003 Plumbing and drainage Water services
    AS 2118.5-2008 Automatic fire sprinkler systems Home fire sprinkler systems (Reconfirmed 2020)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective