Polybutylene (PB) plumbing pipe systems - Metric series Metric polybutylene (PB) pipes for hot and cold water applications (Reconfirmed 2017)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

21-02-2007

€45.79
Excluding VAT

Sets out requirements for materials, dimensions and performance for polybutylene pipe for hot and cold water applications (metric series), including domestic, industrial and agricultural purposes.

Committee
PL-006
DocumentType
Standard
ISBN
0 7337 8032 6
Pages
11
ProductNote
Reconfirmed 19/05/2017.This standard has been reconfirmed in Australia in 2017 and remains current in New Zealand. Reconfirmation Notice 19/05/2017
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies materials, dimensions and performance requirements for polybutylene pipe for hot and cold water applications, including domestic, industrial and agricultural purposes.In the interests of serviceability of the pipe, and irrespective of the calculated minimum wall thickness, a minimum wall thickness of 1.6 mm is intended for pipes joined together with mechanical fittings and 2.2 mm is intended for pipes joined together by fusion.NOTES:1 Polybutylene undergoes a crystalline transition after it has cooled from the molten state. As a consequence, pipe manufactured to this Standard will not have achieved its full strength until 10 days after the date of manufacture, i.e., the date stamped on the pipe. Precautions should be taken to ensure that pipe is not released from the manufacturer’s control prematurely and installed before gaining full strength.2 Polybutylene pipe manufactured in accordance with this Standard is only considered suitable for use in situations exposed to indirect sunlight if it is stabilized against ultraviolet degradation. The only allowable method of stabilization is by the addition of 2.25 (0.25( of carbon black. Polybutylene pipe should never be used in situations where pipe is continuously exposed to direct sunlight.3 Polybutylene pipe manufactured in accordance with this Standard is intended to be used with fittings complying with AS 5082.2. Joining polybutylene pipe by means of solvent cement is not satisfactory.4 Type tests specified in Clauses 9.1, 9.4, 9.7, 10.2 and 10.3 are tests performed on pipe, following the crystalline transition time, to assess compliance of finished product with this Standard; however, it may also be convenient for product manufacturers to use those tests for quality control purposes during manufacture.

First published as AS 5082.1-2007.
Reissued incorporating Amendment No. 1 (November 2018).

AS/NZS 1462.19:2006 Methods of test for plastics pipes and fittings C-ring test for fracture toughness of PVC pipes (Reconfirmed 2017)
AS/NZS 4020:2005 Testing of products for use in contact with drinking water
AS 1199.1-2003 Sampling procedures for inspection by attributes Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection (Reconfirmed 2016)
AS 5082.2-2007 Polybutylene (PB) plumbing pipe systems - Metric series Mechanical and fusion jointing systems (Reconfirmed 2017)
AS/NZS 1462.6:1998 Methods of test for plastics pipes and fittings - Method for hydrostatic pressure testing of pipes
AS/NZS 4131:2003 Polyethylene (PE) compounds for pressure pipes and fittings
AS/NZS 1462.13:2006 Methods of test for plastics pipes and fittings Method for the determination of elastomeric seal joint contact width and pressure (Reconfirmed 2017)
AS/NZS 1462.11:1996 Methods of test for PVC pipes and fittings Method for high temperature stress-relief testing of fittings (Reconfirmed 2017)
AS/NZS 1462.15:1996 Methods of test for PVC pipes and fittings Method for determination of vinyl chloride monomer content (Reconfirmed 2017)
HB 18.28-2005 Conformity assessment - Guidance on a third-party certification system for products
AS/NZS 2642.1:1994 Polybutylene pipe systems - Polybutylene (PB) pipe extrusion compounds
AS/NZS 1462.1:2006 Methods of test for plastics pipes and fittings Method for determining the dimensions of pipes and fittings (Reconfirmed 2024)
AS/NZS 3500.0:2003 Plumbing and drainage Glossary of terms
AS/NZS 1462.16:2006 Methods of test for plastics pipes and fittings Method for high temperature testing of pipe (Reconfirmed 2017)
AS/NZS 1462.14:1996 Methods of test for PVC pipes and fittings Method for determination of the light transmission of pipe (Reconfirmed 2017)
AS/NZS 1462.10:1998 Methods of test for plastics pipes and fittings Method for hydrostatic pressure testing of fittings and elastomeric seal joints for non-pressure applications (Reconfirmed 2017)

AS/NZS 3500.4:2015 Plumbing and drainage Heated water services
AS/NZS 3500.1:2018 Plumbing and drainage Water Services
AS/NZS 3500.5:2012 Plumbing and drainage Housing installations
AS 5082.2-2007 Polybutylene (PB) plumbing pipe systems - Metric series Mechanical and fusion jointing systems (Reconfirmed 2017)
AS/NZS 4020:2018 Testing of products for use in contact with drinking water
AS/NZS 3500.4:2018 Plumbing and drainage Heated water services

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.