AS 5414-2012

Current

Current

The latest, up-to-date edition.

Bushfire water spray systems

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

20-08-2012

€77.79
Excluding VAT

Specifies general requirements for the design, installation and maintenance of water spray systems intended to provide a degree of building protection against bushfire exposure, including ember attack, together with limited protection against radiant heat exposure (up to 19kW/m2 (BAL19).

Committee
FP-024
DocumentType
Standard
ISBN
978 1 74342 213 7
Pages
30
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard sets out general requirements for the design, installation and maintenance ofwater spray systems intended to provide a degree of building protection against bushfireexposure, including ember attack, together with limited protection against radiant heatexposure [up to 19 kW/m2(BAL 19)]. Bushfire water spray systems are intended tocomplement the requirements of AS 3959, and should be considered as one component of aholistic fire management plan.NOTE: For further guidance see Appendix B of this Standard and the site assessment aspects ofAS 3959.It is recognized that installation of a bushfire water spray system is to be preceded by someform of on-site evaluation by a qualified bushfire assessment practitioner. In such cases it isrecommended that the practitioner witness the system commissioning test and countersignthe completion certificate.NOTE: Where required, a copy of the completion certificate should be forwarded to the localgovernment authority and the fire service concerned.Bushfire water spray systems may be used for protection against bushfire ember attack onBCA Class 1a, 1b, 2, 3 and 9c buildings, particularly existing buildings which are not fullycompliant with the requirements of AS 3959.

First published as AS 5414-2012.

AS/NZS 3500.1:2003 Plumbing and drainage Water services
AS 2118.4-2012 Automatic fire sprinkler systems Sprinkler protection for accommodation buildings not exceeding four storeys in height
AS 4118.1.6-1995 Fire sprinkler systems Components - Stop valves and non-return valves (Reconfirmed 2013)
AS 4118.1.1-1996 Fire sprinkler systems Components - Sprinklers and sprayers (Reconfirmed 2013)
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 4118.2.1-1995 Fire sprinkler systems Piping - General (Reconfirmed 2013)
AS 3959-2009 Construction of buildings in bushfire-prone areas

AS/NZS 3500.1:2018 Plumbing and drainage Water Services

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.