• Shopping Cart
    There are no items in your cart

AS 60068.2.57-2003

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Environmental testing Tests - Test Ff: Vibration - Time-history method

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

30-01-2019

Language(s)

English

Published date

01-01-2003

€77.79
Excluding VAT

1 - AS 60068.2.57-2003 ENVIRONMENTAL TESTING - TESTS-TEST Ff: VIBRATION-TIME-HISTORY METHOD
4 - PREFACE
5 - CONTENTS
7 - INTRODUCTION
9 - 1 Scope and object
9 - 2 Normative references
9 - 3 Definitions
10 - 3.1 critical frequency
10 - 3.2 damping
10 - 3.3 critical damping
10 - 3.4 damping ratio
10 - 3.5 signal tolerance
10 - 3.6 fixing point
10 - 3.7 Gn
10 - 3.8 high peaks of the response
11 - 3.9 measuring points
11 - 3.9.1 check point
11 - 3.9.2 reference point
11 - 3.10 natural frequency
11 - 3.11 natural time-history
11 - 3.12 oscillator
11 - 3.13 pause
11 - 3.14 preferred testing axes
12 - 3.15 random motion sample
12 - 3.16 required response spectrum
12 - 3.17 response spectrum
12 - 3.18 sampling frequency
12 - 3.19 strong part of the required response spectrum
12 - 3.20 strong part of the time-history
12 - 3.21 sweep cycle
12 - 3.22 synthesized time-history
12 - 3.23 test level
12 - 3.24 test response spectrum
12 - 3.25 time-history
13 - 3.26 zero period acceleration
13 - 4 General requirements
13 - 5 Requirements for testing
13 - 5.1 Vibration response investigation
13 - 5.1.1 Basic motion
13 - 5.1.2 Spurious motion
14 - 5.1.3 Signal tolerance
14 - 5.1.4 Vibration amplitude tolerances
15 - 5.1.5 Frequency tolerances
15 - 5.1.6 Sweeping
15 - 5.1.7 Damping ratio
15 - 5.2 Time- history testing
15 - 5.2.1 Basic motion
16 - 5.2.2 Transverse motion
16 - 5.2.3 Rotational motion
16 - 5.2.4 Tolerance zone for the required response spectrum
16 - 5.2.5 Frequency range
16 - 5.2.6 Calculation of the test response spectrum
17 - 5.3 Mounting
17 - 6 Severities
18 - 6.1 Test frequency range
18 - 6.2 Required response spectrum
18 - 6.3 Number and duration of time-histories
18 - 6.3.1 Number of time-histories
19 - 6.3.2 Time-history duration
19 - 6.3.3 Duration of the strong part of the time-history
19 - 6.4 Number of high peaks of the response
19 - 7 Preconditioning
19 - 8 Initial measurements
20 - 9 Testing
20 - 9.1 General
20 - 9.2 Vibration response investigation
20 - 9.3 Time-history testing
21 - 9.3.1 Single axis testing
21 - 9.3.2 Biaxial testing
21 - 9.3.3 Triaxial testing
21 - 10 Intermediate measurements
21 - 11 Recovery
21 - 12 Final measurements
22 - 13 Information to be given in the relevant specification
29 - Annex A - Synthesis of the artificial time- history: Guidance
29 - A.1 Introduction
30 - A.2 Recommendations for obtaining a required response spectrum (see 6.2)
31 - A.3 Number of high peaks of the response (see 6.4)
33 - Annex B - Test frequency ranges

Provides a standard procedure for determining, by the time-history method, the ability of a specimen to withstand specified severities of transient vibration.

Committee
EL-026
DocumentType
Standard
ISBN
0 7337 5294 2
Pages
25
ProductNote
Withdrawn 30-01-2019.
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

This part of IEC 60068 aims to provide a standard procedure for determining, by the time-historymethod, the ability of a specimen to withstand specified severities of transient vibration.

Standards Relationship
IEC 60068-2-57:1999 Identical

First published as AS 60068.2.57-2003.

AS 60118.7-2007 Hearing aids Measurement of the performance characteristics of hearing aids for production, supply and delivery quality assurance purposes (Reconfirmed 2019)
AS 60118.9-2007 Hearing aids Methods of measurement of characteristics of hearing aids with bone vibrator output (Reconfirmed 2019)
AS/NZS 61000.4.7:2012 Electromagnetic compatibility (EMC) Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto (Reconfirmed 2023)
AS 2067-2008 Substations and high voltage installations exceeding 1 kV a.c.
AS 60947.5.4-2004 Low-voltage switchgear and controlgear Control circuit devices and switching elements - Methods of assessing the performance of low-energy contacts - Special tests
AS 2650-2005 Common specifications for high-voltage switchgear and controlgear standards (IEC 60694 Ed.2.2(2002) MOD)
AS 62271.1-2012 High-voltage switchgear and controlgear Common specifications

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.