• AS 60146.1.3-2002

    Current The latest, up-to-date edition.

    Semiconductor converters General requirements and line commutated converters - Transformers and reactors

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  04-07-2002

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 60146.1.3-2002 SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS-TRANSFORMERS AND REACTORS
    4 - PREFACE
    5 - CONTENTS
    7 - 1 Scope
    7 - 2 Normative references
    8 - 3 Rated values for converter transformers
    8 - 3.1 Rated current values
    8 - 3.1.1 Single converter or double converter supplied from one common cell winding
    8 - 3.1.2 Double converter where each thyristor assembly has separate cell windings
    8 - 3.2 Temperature limits of cooling media
    8 - 3.2.1 Air cooled outdoor equipment
    8 - 3.2.2 Air cooled indoor equipment
    8 - 3.2.3 Water cooled equipment
    8 - 4 Losses and voltage drops in transformers and reactors
    8 - 4.1 Losses in the transformer windings
    9 - 4.2 Losses in interphase transformers, current balancing reactors, series-smoothing reactors, transductors and other current regulating accessories
    9 - 4.2.1 lnterphase transformers
    9 - 4.2.2 Current balancing reactors
    9 - 4.2.3 Series-smoothing reactors
    9 - 4.2.4 Transductors and other current regulating accessories
    10 - 4.3 Voltage drops in transformers and reactors
    10 - 5 Tests for converter transformers
    10 - 5.1 Measurement of commutating reactance and determination of inductive voltage drop (type test)
    10 - 5.1.1 Commutating reactance
    10 - 5.1.2 Inductive voltage regulation
    11 - 5.2 Short-circuit test (type test and routine test)
    11 - 5.3 Temperature rise test (type test)
    15 - Annex A - Corrections to be applied when cooling medium temperature is higher than standard

    Abstract - (Show below) - (Hide below)

    Specifies characteristics where converter transformers differ from ordinary power transformers. This Standard has been reproduced from and is technically identical to IEC 60146-1-3:1991.

    Scope - (Show below) - (Hide below)

    This Part 1-3 of the International Standard relates, in general, to those characteristics wherein converter transformers differ from ordinary power transformers. In all other respects, the rules specified in IEC 76 shall apply to converter transformers also, as far as they are not in contradiction with this Standard.It should be borne in mind that a rectifier transformer operates with non-sinusoidal current waveshape. In single-way connection, the current in each cell winding contains a d.c. component which calls for special attention in design and testing. In some cases, a special design is necessary when external short-circuits and cell failures would cause abnormal stress.For certain types of transformers, the waveshape of the normal operating voltage is non-sinusoidal. The core loss of such equipment is to be determined by applying a sinusoidal voltage having the same half-cycle arithmetic mean value and the same fundamental frequency as the voltage applied in service.

    General Product Information - (Show below) - (Hide below)

    Committee EL-027
    Document Type Standard
    Product Note This standard has been reconfirmed in Australia in 2013 and remains current in New Zealand. Reconfirmation Notice 13-01-2014
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    First published as part of AS 1955.1-1977.Revised and redesignated in part as AS 60146.1.3-2002.Reconfirmed 2013. First published as part of AS 1955.1-1977. Revised and redesignated in part as AS 60146.1.3-2002.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 60146.1.1-2002 Semiconductor converters General requirements and line commutated converters - Specifications of basic requirements
    AS 60146.1.2-2002 Semiconductor converters General requirements and line commutated converters - Application guide

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
    AS 61800.4-2007 Adjustable speed electrical power drive systems General requirements - Rating specifications for a.c. power drive systems above 1000 V a.c. and not exceeding 35 kV (Reconfirmed 2016)
    AS 61800.1-2007 Adjustable speed electrical power drive systems General requirements - Rating specifications for low voltage adjustable speed d.c. power drive systems (Reconfirmed 2016)
    AS 61800.2-2004 Adjustable speed electrical power drive systems General requirements - Rating specifications for low voltage adjustable frequency a.c. power drive systems
    AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective