• AS 60270-2001

    Current The latest, up-to-date edition.

    High-voltage test techniques - Partial discharge measurements

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  01-01-2001

    Publisher:  Standards Australia

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Applies to the measurement of partial discharges which occur in electrical apparatus, components or systems when tested with alternating voltages up to 400 Hz or with direct voltage. Defines the quantities to be measured and describes test and measuring circuits which may be used. It is intended that the provisions of this Standard should be used in the drafting of specifications relating to partial discharge measurements for specific power apparatus. This Standard is identical to and has been reproduced from IEC 60270:2000.

    Scope - (Show below) - (Hide below)

    This International Standard is applicable to the measurement of partial discharges which occur in electrical apparatus, components or systems when tested with alternating voltages up to 400 Hz or with direct voltage.This standard– defines the terms used;– defines the quantities to be measured;– describes test and measuring circuits which may be used;– defines analogue and digital measuring methods required for common applications;– specifies methods for calibration and requirements of instruments used for calibration;– gives guidance on test procedures;– gives some assistance concerning the discrimination of partial discharges from external interference.The provisions of this standard should be used in the drafting of specifications relating to partial discharge measurements for specific power apparatus. It deals with electrical measurements of impulsive (short-duration) partial discharges, but reference is also made to non-electrical methods primarily used for partial discharge location (see annex F).Diagnosis of the behaviour of specific power apparatus can be aided by digital processing of partial discharge data (see annex E) and also by non-electrical methods that are primarily used for partial discharge location (see annex F).This standard is primarily concerned with electrical measurements of partial discharges made during tests with alternating voltage, but specific problems which arise when tests are made with direct voltage are considered in clause 11.The terminology, definitions, basic test circuits and procedures often also apply to tests with other frequencies, but special test procedures and measuring system characteristics, which are not considered in this standard, may be required.Annex A provides normative requirements for performance tests on calibrators.

    General Product Information - (Show below) - (Hide below)

    Committee EL-007
    Document Type Standard
    Product Note Reconfirmed 18/05/2015.This standard as been reconfirmed in Australia in 2015 and remains current in New Zealand. Reconfirmation Notice 18/05/2015
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    First published as AS 1018-1970.Second edition 1985.Revised and redesignated as AS 60270-2001.Reconfirmed 2015. First published as AS 1018-1970. Second edition 1985. Revised and redesignated as AS 60270-2001.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
    AS 1931.2-1996 High-voltage test techniques - Measuring systems

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 60044.2-2007 Instrument transformers Inductive voltage transformers (IEC 60044-2:Ed.1.2 (2003) MOD)
    AS/NZS 1300:2009 Electrical equipment for mines and quarries - Bolted explosion-protected three-phase cable coupling devices (Reconfirmed 2020)
    AS/NZS 60137:2008 Insulated bushings for alternating voltages above 1000 V (IEC 60137, Ed. 5.0 (2003) MOD)
    AS/NZS 60076.3:2008 Power transformers Insulation levels, dielectric tests and external clearances in air (IEC 60076-3, Ed. 2 (2000) MOD)
    AS/NZS 2081:2011 Electrical protection devices for mines and quarries (Reconfirmed 2022)
    AS 62271.200-2005 High-voltage switchgear and controlgear A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV (IEC 62271-200, Ed. 1 (2003) MOD)
    AS 2629-2008 Separable insulated connectors for power distribution systems above 1 kV (Reconfirmed 2019)
    AS 60044.1-2007 Instrument transformers Current transformers (IEC 60044-1 Ed.1.2 (2003) MOD)
    AS 62271.201-2008 High-voltage switchgear and controlgear AC insulation-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    AS 60214.1-2005 Tap-changers Performance requirements and test methods
    AS 60076.11-2006 Power transformers Dry-type transformers
    AS/NZS 60076.6:2013 Power transformers Reactors
    AS 60044.5-2004 Instrument transformers Capacitor voltage transformers
    AS 60265.2-2005 High-voltage switches High-voltage switches for rated voltages of 52 kV and above (IEC 60265-2, Ed.1.0(1988) MOD)
    AS 62271.203-2012 High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    AS 2650-2005 Common specifications for high-voltage switchgear and controlgear standards (IEC 60694 Ed.2.2(2002) MOD)
    AS/NZS 4871.1:2012 Electrical equipment for mines and quarries General requirements
    AS 62271.1-2012 High-voltage switchgear and controlgear - Common specifications
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective