• AS/NZS 2373.2:1995

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electric cables for control and protection circuits - Twisted pair control cables

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2017

    Language(s):  English

    Published date:  01-01-1995

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS/NZS 2373.2:1995 ELECTRIC CABLES FOR CONTROL AND PROTECTION CIRCUITS - TWISTED PAIR CONTROL CABLES
    4 - PREFACE
    5 - CONTENTS
    6 - 1 SCOPE
    6 - 2 REFERENCED DOCUMENTS
    6 - 3 DEFINITIONS
    6 - 3.1 Control cable
    6 - 3.2 Lay-up
    6 - 3.3 Routine tests
    6 - 3.4 Special tests
    6 - 3.5 Type tests
    7 - 3.6 Voltage designation
    7 - 3.7 Wavelength or length of lay
    7 - 4 VOLTAGE DESIGNATION
    7 - 5 CONDUCTORS
    7 - 6 INSULATION
    7 - 6.1 Material
    7 - 6.2 Application
    7 - 6.3 Thickness
    7 - 6.4 Criteria
    7 - 6.5 Identification of twisted pairs
    7 - 7 NUMBER OF CORES AND CONFIGURATION
    7 - 8 LAY-UP OF TWISTED PAIRS
    7 - 8.1 Length of lay of twisted pairs
    7 - 8.2 Lay-up of the twisted pairs
    8 - 9 FILLERS AND BINDERS
    8 - 10 BINDER TAPE
    8 - 11 COLLECTIVE INSULATION
    8 - 11.1 Application
    8 - 11.2 Thickness
    9 - 12 METALLIC SCREENS
    9 - 12.1 Application
    9 - 12.2 Material
    9 - 12.3 Continuity conductor
    9 - 13 MOISTURE BARRIER
    9 - 14 BEDDING
    9 - 15 METALLIC SHEATH
    9 - 16 SEPARATION SHEATH
    9 - 17 ARMOUR
    9 - 18 NON-METALLIC SHEATH
    9 - 18.1 Material
    9 - 18.2 Construction
    10 - 18.3 Thickness
    10 - 18.4 Web dimensions
    10 - 19 INSECT-RESISTANT BARRIER
    10 - 20 CATENARY SUPPORT WIRES
    10 - 20.1 Material
    10 - 20.2 Dimensions
    10 - 21 MARKING
    10 - 21.1 Information to be marked
    10 - 21.2 Means of marking
    11 - 21.3 Metre marking
    11 - 21.4 Marking of drums, coils or reels
    11 - 22 CONSTRUCTION AND DIMENSIONS
    15 - 23 TESTING
    15 - 24 GUIDE TO BENDING RADIUS
    16 - APPENDIX A - THE FICTITIOUS CALCULATION METHOD FOR THE DETERMINATION OF THE DIMENSIONS OF PROTECTIVE COVERINGS
    16 - A1 INTRODUCTION
    16 - A2 GENERAL
    16 - A3 METHOD
    16 - A3.1 Conductors
    16 - A3.2 Cores
    17 - A3.3 Diameter over laid-up pairs
    17 - A3.4 Collective insulation
    17 - A3.5 Bedding
    17 - A3.6 Metallic screen
    18 - A3.7 Moisture barrier
    18 - A3.8 Separation sheath
    18 - A3.9 Metal sheath
    18 - A3.10 Armour
    19 - A3.11 Non-metallic sheath
    19 - A3.12 Polyamide jacket
    20 - APPENDIX B - PURCHASING GUIDELINES
    20 - B1 GENERAL
    20 - B2 INFORMATION TO BE SUPPLIED BY THE PURCHASER
    21 - APPENDIX C - HIGH VOLTAGE TESTS
    21 - C1 HIGH VOLTAGE TEST FOR TWISTED-PAIR CABLES
    21 - C1.1 Test voltage
    21 - C1.2 Test method
    22 - APPENDIX D - GUIDE TO BENDING RADIUS OF NON-AERIAL TWISTED PAIR CONTROL CABLES
    22 - D1 METHOD
    22 - D2 MINIMUM BENDING RADIUS
    23 - APPENDIX E - ROUNDING OF NUMBERS
    23 - E1 ROUNDING OF NUMBERS FOR THE PURPOSE OF THE ‘FICTITIOUS CALCULATION METHOD
    23 - E2 ROUNDING OF NUMBERS FOR OTHER PURPOSES

    Abstract - (Show below) - (Hide below)

    Specifies the requirements for screened polyethylene (PE) insulated twisted pair control cables for voltages up to 0.6/1 kV, including a catenary support wire for aerial cables, intended for use in control, supervisory, protection and instrumentation circuits. It does not apply to cables used solely for telecommunication purposes.

    Scope - (Show below) - (Hide below)

    This Standard specifies requirements for screened polyethylene(PE) insulated twisted pair control cables for voltages up to and including 0.6/1 kV. A catenary support wire is included for aerial cables.It applies to cables intended for use in control, supervisory, protection and instrumentation circuits. Control cables complying with this Standard may be used between power stations, substations or in industrial applications.It does not apply to cables used solely for telecommunication.

    General Product Information - (Show below) - (Hide below)

    Committee EL-003
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    Under Revision see DR 02567 First published as AS 2373.2-1982.Jointly revised and designated as Joint Standard AS/NZS 2373.2:1995. First published as AS 2373.2-1982. Jointly revised and designated as Joint Standard AS/NZS 2373.2:1995.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 1222.1-1992 Steel conductors and stays - Bare overhead Galvanized (SC/GZ) (Reconfirmed 2016)
    AS 3147-1992 Approval and test specification - Electric cables - Thermoplastic insulated - For working voltages up to and including 0.6/1 kV
    AS 1125-1993 Conductors in insulated electric cables and flexible cords
    AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 3808:1998 Insulating and sheathing materials for electric cables
    AS/NZS 3808:2000 Insulating and sheathing materials for electric cables
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective