AS/NZS 3008.1.2:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
02-03-2023
English
22-04-2010
This Standard sets out a method for cable selection for those types of electrical cables and methods of installation that are in common use at working voltages up to and including 0.6/1 kV at 50 Hz a.c.
Committee |
EL-001
|
DocumentType |
Standard
|
ISBN |
978 1 86975 128
|
Pages |
126
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard sets out a method for cable selection for those types of electrical cables and methods of installation that are in common use at working voltages up to and including 0.6/1 kV at 50 Hz a.c.Three criteria are given for cable selection, as follows:Current-carrying capacity.Voltage drop.Short-circuit temperature rise.This Standard provides sustained current-carrying capacities and voltage drop values for those types of electrical cable and installation practices in common use in New Zealand. A significant amount of explanatory material is also provided on the application of rating factors that arise from the particular installation conditions of a single circuit or groups of circuits. Also, provided in Section 5 is information on cable selection based on short-circuit temperature limits. A number of worked examples on cable selection are included in Appendix A.This Standard does not take into account the effects that may occur owing to temperature rise at the terminals of equipment and reference is necessary to AS/NZS 3000 and the individual equipment Standards. For ease of reference, an index of the Tables included in this Standard is provided in Appendix B.
Originated in Australia as AS 3008.1 1984.
Second edition 1989.
Jointly revised and redesignated AS/NZS 3008.1.2:1998.
Fourth edition 2010.
AS/NZS 3191:2008 | Electric flexible cords (Reconfirmed 2019) |
AS 1531-1991 | Conductors - Bare overhead - Aluminium and aluminium alloy (Reconfirmed 2016) |
AS/NZS 5000.3:2003 | Electric cables - Polymeric insulated Multicore control cables (Reconfirmed 2017) |
AS/NZS 4961:2003 | Electric cables - Polymeric insulated - For distribution and service applications (Reconfirmed 2017) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 60702.1:2005 | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V Cables |
AS/NZS 3560.2:2003 | Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1 (1.2) kV Copper conductors |
AS/NZS 1125:2001 | Conductors in insulated electric cables and flexible cords (Reconfirmed 2017) |
AS 1746-1991 | Conductors - Bare overhead - Hard-drawn copper |
AS/NZS 5000.2:2006 | Electric cables - Polymeric insulated For working voltages up to and including 450/750 V (Reconfirmed 2017) |
AS/NZS 3008.1.1:2009 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS/NZS 4026:2008 | Electric cables - For underground residential distribution systems |
AS 3158-2004 | Electric cables - Glass fibre insulated - For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2016) |
AS/NZS 3560.1:2000 | Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021) |
AS/NZS 5000.1:2005 | Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017) |
AS/NZS 3012:2010 | Electrical installations - Construction and demolition sites |
AS/NZS 4777.1:2016 | Grid connection of energy systems via inverters Installation requirements |
AS/NZS 4871.1:2010 | Electrical equipment for mines and quarries General requirements |
AS/NZS 3008.1.1:2017 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS/NZS 3003:2011 | Electrical installations - Patient areas |
AS/NZS 5033:2012 | Installation and safety requirements for photovoltaic (PV) arrays |
AS/NZS 61009.1:2011 | Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 3.0 (2010) MOD) |
AS/NZS 4871.1:2012 | Electrical equipment for mines and quarries General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.