• Shopping Cart
    There are no items in your cart

AS/NZS 3008.1.2:2010

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

02-03-2023

Superseded by

AS/NZS 3008.1.2:2017

Language(s)

English

Published date

22-04-2010

€143.89
Excluding VAT

This Standard sets out a method for cable selection for those types of electrical cables and methods of installation that are in common use at working voltages up to and including 0.6/1 kV at 50 Hz a.c.

Committee
EL-001
DocumentType
Standard
ISBN
978 1 86975 128
Pages
126
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out a method for cable selection for those types of electrical cables and methods of installation that are in common use at working voltages up to and including 0.6/1 kV at 50 Hz a.c.Three criteria are given for cable selection, as follows:Current-carrying capacity.Voltage drop.Short-circuit temperature rise.This Standard provides sustained current-carrying capacities and voltage drop values for those types of electrical cable and installation practices in common use in New Zealand. A significant amount of explanatory material is also provided on the application of rating factors that arise from the particular installation conditions of a single circuit or groups of circuits. Also, provided in Section 5 is information on cable selection based on short-circuit temperature limits. A number of worked examples on cable selection are included in Appendix A.This Standard does not take into account the effects that may occur owing to temperature rise at the terminals of equipment and reference is necessary to AS/NZS 3000 and the individual equipment Standards. For ease of reference, an index of the Tables included in this Standard is provided in Appendix B.

Originated in Australia as AS 3008.1 1984.
Second edition 1989.
Jointly revised and redesignated AS/NZS 3008.1.2:1998.
Fourth edition 2010.

AS/NZS 3191:2008 Electric flexible cords (Reconfirmed 2019)
AS 1531-1991 Conductors - Bare overhead - Aluminium and aluminium alloy (Reconfirmed 2016)
AS/NZS 5000.3:2003 Electric cables - Polymeric insulated Multicore control cables (Reconfirmed 2017)
AS/NZS 4961:2003 Electric cables - Polymeric insulated - For distribution and service applications (Reconfirmed 2017)
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 60702.1:2005 Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V Cables
AS/NZS 3560.2:2003 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1 (1.2) kV Copper conductors
AS/NZS 1125:2001 Conductors in insulated electric cables and flexible cords (Reconfirmed 2017)
AS 1746-1991 Conductors - Bare overhead - Hard-drawn copper
AS/NZS 5000.2:2006 Electric cables - Polymeric insulated For working voltages up to and including 450/750 V (Reconfirmed 2017)
AS/NZS 3008.1.1:2009 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS/NZS 4026:2008 Electric cables - For underground residential distribution systems
AS 3158-2004 Electric cables - Glass fibre insulated - For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2016)
AS/NZS 3560.1:2000 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021)
AS/NZS 5000.1:2005 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017)

AS/NZS 3012:2010 Electrical installations - Construction and demolition sites
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
AS/NZS 4871.1:2010 Electrical equipment for mines and quarries General requirements
AS/NZS 3008.1.1:2017 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS/NZS 3003:2011 Electrical installations - Patient areas
AS/NZS 5033:2012 Installation and safety requirements for photovoltaic (PV) arrays
AS/NZS 61009.1:2011 Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 3.0 (2010) MOD)
AS/NZS 4871.1:2012 Electrical equipment for mines and quarries General requirements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.